汤姆(Trane)XR17-4TWR7-2-5吨拆分系统热泵产品数据发布号22-1886-6C-EN.docx
Split System Heat Pump Product DataXR174TWR72, 3, 4 & 5 TonsPUB. NO. 22-1886-6C-EN Features and Benefits CLIMATUFF 2-stage scroll compressor Efficiency up to 18.0 SEER and9.5 HSPF All Aluminum SPINE FIN coil DURATUFF weather proof and rust proof base COMFORT ”R” mode approved for better comfort indoors QUICK-SESS cabinet, service access and refrigerant connections with full coil protection WEATHERGUARD fasteners Glossy corrosion resistant finish tarpaulin gray cabinet with anthracite gray top Internal compressor high/low pressure & temperature protection Liquid line filter/drier Low sound with advanced PSC fan motor Service valve cover R-410A refrigerant From 70 to 100% capacity modulation 100% run test in the factory Low ambient cooling to 55° as shipped Extended warranties available© 2019 Trane222-1886-6C-EN ContentsFeatures and Benefits 2General Data 4Product Specifications4A-weighted Sound Power Level dB(A)4Accessory Description and Usage5AHRI Standard Capacity Rating Conditions5Model Nomenclature 6Electrical Data 7Dimensions 10Mechanical Specifications 1122-1886-6C-EN3General DataProduct SpecificationsModel No. 4TWR7024B1000AA4TWR7036B1000D4TWR7048A1000D4TWR7060A1000DElectrical Data V/Ph/Hz 208/230/1/60208/230/1/60208/230/1/60208/230/1/60Min Cir Ampacity15212837Max Fuse Size (Amps)25354560CompressorCLIMATUFF® - SCROLLCLIMATUFF® - SCROLLCLIMATUFF® - SCROLLCLIMATUFF® - SCROLLNo. Compress. No. Stages1 -21-21-21-2RL AMPS - LR AMPS11.7 - 58.315.3 - 8321.2 - 10428.8 - 152.9Outdoor Fan FL Amps0.710.741.051.30Fan HP1/81/81/51/4Fan Dia (inches)27.627.8727.627.6CoilSpine FinSpine FinSpine FinSpine FinRefrigerant R-410A9/0-LB/OZ9/4-LB/OZ12/9-LB/OZ12/10-LB/OZLine Size - (in.) O.D. Gas 5/83/47/81-1/8Line Size - (in.) O.D. Liquid 3/83/83/83/8Dimensions H x W x D (Crated)46.4 x 35.1 x 38.746.4 X 35.1 X 38.751.0 x 35.1 x 38.751.0 x 35.1 x 38.7Weight - Shipping272258329330Weight - Net236210292293Start ComponentsNONONONOSound EnclosureNONONONOCompressor Sump HeatYESYESYESYESOptional Accessories: Rubber Isolator KitBAYISLT101BAYISLT101BAYISLT101BAYISLT101Snow Leg - 7" HighBAYLEGS007BAYLEGS007BAYLEGS007BAYLEGS007Snow Leg - 4" HighBAYLEGS004BAYLEGS004BAYLEGS004BAYLEGS004Hard Start Kit ScrollBAYKSKT263BAYKSKT263BAYKSKT266BAYKSKT266Extreme Condition Mounting KitBAYECMT004BAYECMT004BAYECMT004BAYECMT004Vertical Discharge Air Kit Base 4BAYVDTA003BAYVDTA004BAYVDTA004BAYVDTA004Auto Charge Solenoid KitBAYCAKT001BAYCAKT001BAYCAKT001BAYCAKT001Refrigerant Lineset TAYREFLN9*TAYREFLN7*TAYREFLN3*TAYREFLN4* Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision) For accessory description and usage, see page 5. * = 15, 20, 25, 30, 40 and 50 foot lineset available.Sound Power LevelModelA-Weighted Sound Power Level dB(A)Full Octave Sound Power dB63 Hz125 Hz250 Hz500 Hz1000 Hz2000 Hz4000 Hz8000 Hz4TWR7024B17267676263625755504TWR7036B17266666464635754484TWR7048A17268736567635653474TWR7060A1745875666866595552Note: Rated in accordance with AHRI Standard 270-2008422-1886-6C-EN General DataAccessory Description and UsageRubber Isolators 5 rubber donuts to isolate condens- ing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized.Extreme Conditions Mounting Kit Bracket kits to secure- ly mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc.Low Ambient Cooling For low ambient cooling below 55° see Application Guide APP-APG013-EN.AHRI Standard Capacity Rating ConditionsAHRI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil.(B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil.(C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil.(D) Rated indoor airflow for heating is the same as for cooling.AHRI STANDARD 270 RATING CONDITIONS (Noiserating numbers are determined with the unit in cooling opera- tion.) Standard Noise Rating number is at 95°F outdoor air.22-1886-6C-EN5Model NomenclatureOutdoor Units4 T W R 7 0 3 6 A 1 0 0 0 A AAir HandlerG A M 5 A 0 B 3 6 M 3 1 S A ARefrigerant Type4 = R-410ATRANEProduct TypeW = Split Heat Pump T = Split CoolingProduct FamilyZ = Leadership Two Stage X = LeadershipR = Replacement/Retail M or B = BasicA = Light CommercialFamily SEER3 = 13 6 = 16 0 = 204 = 14 8 = 185 = 15 9 = 19Split System Connections 1-6 Tons0 = BrazedNominal Capacity in 000s of BTUs Major Design Modifications Power Supply1 = 200-230/1/60 or 208-230/1/603 = 200-230/3/604 = 460/3/60Secondary FunctionMinor Design Modifications Unit Parts IdentifierBrandT = Better G = GoodProduct TypeA = Air HandlerConvertabilityM = Multi-poise 4-wayF = Upflow Front Return, 3-way T = 3-wayProduct Tier2 = Good, Entry Level Feature Set4 = Better, Retail Replacement Mid Effy.5 = Better, Entry Level High Effy., Multi-Speed 7 = Best, Retail Replacement High Effy.,Variable-Speed8 = Best, Retail Ultimate High Effy., Variable-SpeedMajor Design ChangeNo Descriptor0 = Air Handler / CoilSize (Footprint)A = 17.5 x 21.5B = 21.0 x 21.5C = 23.5 x 21.5Cooling Size: Air Handler or Coil0-9 = AH Coil - 1000 BTUs (18, 24, 30, 36, 42, 48, 60)Airflow Type & CapabilityS = Low Effy PSC, 1-5 - nom. Tonnage (cfm/ton)M = Mid Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) H = High Effy Multi-Speed, 1-5 - nom. Tonnage (cfm/ton) V = High Effy Variable, 1-5 - nom. Tonnage (cfm/ton)Power Supply1 = 208-230/1/60System Control Type S = Standard - 24 VAC C = CLII 13.8 VDCMinor Design ChangeGas FurnacesFurnace Configuration TU = Upflow/Horizontal TD = Downflow/HorizontalTypeE = 80% Induced Draft Standard D = 80% Induced Draft Premium C = 90% Condensing StandardT U D 1 B 0 8 0 A 9 H 3 1 A AUnit Parts IdentifierHeat Pump/ Cooling CoilsRefrigerant Type4 = R-410ASeries 4 T X C B 0 3 6 A C 3 H C A AX = 90% Condensing Premium H = 95% Condensing PremiumNumber of Heating Stages1 = Single Stage2 = Two Stage M = ModulatingCabinet WidthA = 14.5" Cabinet WidthB = 17.5" Cabinet WidthC = 21.0" Cabinet WidthD = 24.5" Cabinet WidthHeating Input in 1000s (BTUH)080 = 80,000 BTUHMajor Design Change Voltage9 = 115 Volts / 60 Hertz / Natural GasA = 115 Volts / 50 Hertz / Natural GasC = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic FilterD = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic FilterAir Capacity for CoolingStandard PSC Variable Speed High Efficiency 24 = 2 TonsV3 = 3 TonsH3 = 3 Tons 36 = 3 TonsV4 = 4 TonsH4 = 4 Tons 42 = 3.5 Tons V5 = 5 TonsH5 = 5 Tons 45 = 4 Tons48 = 4 Tons54 = 5 Tons60 = 5 Tons72 = 6 TonsDraft Inducer Speeds1 = Single Speed2 = Two SpeedV = Variable SpeedMinor Design ChangeT = Premium (Heat Pump or Convertible Coil)C = Standard (Cooling Only)Coil DesignX = Direct Expansion Evaporator CoilCoil FeatureC = Cased A CoilA = Uncased A CoilF = Cased Horizontal Flat CoilCoil Width (Cased/Uncased)A = 14.5" /13.3"B = 17.5" / 16.3"C = 21.0" / 19.8"D = 24.5" / 23.3"H = 10.5"Refrigerant Line Coupling0 = BrazedNominal Capacity in 1000's (BTUH) Major Design ChangeEfficiencyC = StandardS = Hi Efficiency (derived from 10 SEER products)Refrigerant Control3 = TXV - Non-BleedCoil Circuitry H = Heat Pump C = CoolingAirflow ConfigurationA = Upflow OnlyU = Upflow / Downflow H = Horizontal OnlyC = Convertible - Upflow, Downflow, Left or Right AirflowMinor Design Change Service Digit - Not Orderable622-1886-6C-EN Electrical DataSchematic Diagrams(SEE LEGEND)Dwg. D159895P014TWR7024B, 036B22-1886-6C-EN7 Electrical DataSchematic Diagrams(SEE LEGEND)4TWR7048A, 060ADrw. D159896P01822-1886-6C-EN Electrical DataSchematic DiagramsLEGEND22-1886-6C-EN9 Dimensions4TWR7 Outline DrawingNote: All dimensions are in MM (Inches).MODELSBASEABCDEFGHJK4TWR7024B41045 (41 1/8)946 (37-1/4)870 (34-1/4)5/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)711 (28)4TWR7036B41045 (41 1/8)946 (37-1/4)870 (34-1/4)3/43/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)711 (28)4TWR7048A41147 (45 1/8)946 (37-1/4)870 (34-1/4)7/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)813 (32)4TWR7060A41147 (45 1/8)946 (37-1/4)870 (34-1/4)1-1/83/8152 (6)98 (3-7/8)219 (8-5/8)86 (3-3/8)813 (32)From Dwg. D1526351022-1886-6C-ENMechanical SpecificationsGeneralThe 4TWR7 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit isdesigned to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide se- lection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application.CasingUnit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Cor- rosion and weatherproof CMBP-G30 DuraTuff base.Refrigerant ControlsRefrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard.CompressorThe Climatuff® 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: centrifugal oil pump and modular plugs for electrical connections.Condenser CoilThe outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.Low Ambient CoolingAs manufactured, this unit has a cooling capability to 55°F. For low ambient cool- ing below 55° see Application Guide.Trane 06/19Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.