水电安装施工方案培训资料150685.docx
水电安装施工方案*工程水电安装施施工方案编制人:审核人:*第三三建设工程程有限责任任公司目 录录一、概述··························································3二、施工前前的准备工工作··········································4三、给排水水安装施工工············································441、施工部部署····················································442、施工程程序····················································53、主要施施工方法················································5四、电气安安装施工···············································101、施工布布署···················································112、施工穿穿插···················································1113、施工程程序···················································1114、施工方方法···················································111五、桥架、电电缆施工············································14六、动力、照照明配电箱箱(盘)安安装····························15七、灯具、开开关、插座座的安装··································15八、劳动力力计划·················································16九、主要施施工机具计计划·········································16十、工程质质量保证上上、防止质质量通病措措施·····················17(一)、严严格执行国国家强制性性标准及行行业标准························17(二)、工工程质量保保证措施··········································171、组织保保证措施··················································1182、技术保保证措施················································183、现场材材料质量管管理措施·······································1884、坚持样样板制、保保证整体施施工质量······························1195、定期质质量分析,实实施动态管管理································119(三)、安安装质量通通病防治措措施·····································19(四)、成成品保护措措施··············································22(五)、工工程质量保保证措施··········································231、室内给给排水···············································232、室内电电气················································243、避雷装装置·················································25十一、工程程工期、安安全、文明明施工及环环境保护措措施·········225保证工期组组织管理措措施·······································225十二、 安全生产、文文明施工措措施······························27十三、检验验批的划分分··········································288(一)、给给排水安装装检验批的的划分··································28(二)、电电气安装检检验批的划划分····································28安 装 工工 程一、慨述*,位位于重庆市市江北区建建新西路335号,重重庆市嘉陵陵江北岸,南南侧紧邻北北滨路,西西侧与华宇宇北国风光光小区接壤壤。本工程程由重庆国兴兴置业有限限公司开发发,*第三建设设工程有限限责任公司承承建,重庆庆市建永工工程监理公公司监理。本本工程为超超限高层,框框架-核核心筒结构构,地上42层层,地下55层,地上上高度1665.855m,地下下高度211.50mm,建筑面面积835594.228。本工程室内内给水立管管采用PSSP钢塑复复合管,GG型和扩口口式管件连连接,水表表后及室内内卫生间给给水支管采采用S4系系列PP-R给水管管,公称压压力等级11.6MPPa,热熔熔连接。本本工程污水水立管、专专用通气管管采用柔性性铸铁管,WW卡箍连接接,底层卫卫生间污水水单独排放放。155层商业污污水管道采采用UPVVC实壁排排水管,承承插胶水粘粘接或弹性性密封圈连连接,高层层屋面雨水水管采用HHRS高层层承压专用用雨水管,承承插连接或或胶结,阳阳台雨水、空空调冷凝水水、管井废废水、多层层屋面雨水水采用加厚厚型UPVVC实壁排排水管,粘粘接连接。地地下室集水水井压力排排水管采用用焊接钢管管,焊接和和法兰连接接。消防电电梯排水管管采用给水水铸铁管。本工程消防防火灾自动动报警线路路及供电线线路、控制制线路暗敷敷时穿阻燃燃PVC管管,埋设在在楼板或墙墙内,埋设设深度不小小于30mmm。明敷敷时穿热镀镀锌钢管,管管外刷防火火涂料。桥桥架水平安安装时支架架间距不大大于1.55m,垂直直安装时支支架间距不不大于2mm,安装距距地高度大大于2.55m。桥架架穿越防火火分区、楼楼层、防烟烟分区时,安安装完成后后用防火材材料封堵。本工程照明明和应急照照明线路采采用阻燃PPVC管,埋埋设在楼板板或墙内,埋埋设深度不不小于300mm,同同类照明不不同回路分分管敷设。走走道、楼梯梯间、卫生生间、车库库选用LEED光源照照明灯,车车库灯具安安装高度22.8m 。电缆采采用桥架敷敷设,电缆缆出桥架采采用热镀锌锌钢管敷设设,所有消消防设备的的供电线缆缆采用矿物物绝缘电缆缆。利用所所有基础地地梁内2根根大于10mmm钢筋焊接接联通作接接地极,无无地梁处采采用40*4热镀锌锌扁钢焊接接联通,防防雷接地、电电气保护进进度共用统统一接地极极,接地电电阻不大于于1欧,屋屋面避雷带带采用12mmm热镀锌圆圆钢沿屋面面、屋架明明设。二、施工前前的准备工工作1、认真阅阅读图纸 施工工前仔细阅阅读安装工工程的平面面图、系统统图、原理理图、施工工说明和设设计变更等等图纸,结结合土建工工程的建施施图和结构构图阅读,了了解整个工工程的全貌貌,熟悉设设计所要求求的施工工工艺和所涉涉及的图集集和规范。2、施工前前的准备 根据据掌握的图图纸情况,组组织好施工工管理人员员和工人,准准备好施工工中所需要要材料、工具具和机械设设备。三、给排水水安装施工工1、施工部部署该工程集水水井为压力力排水,管管道采用焊焊接钢管焊焊接,电梯梯排水采用用给水铸铁管管承插连接。给给水管道仅仅施工水表表后管段,给给水管材为为PP-RR塑料给水水管热熔连连接。本工工程屋面雨雨水管采用用HRS高高层承压专专用雨水管管,承插胶胶结。阳台台雨水、空调排水水、管井废水水、多层屋屋面雨水采采用加厚型型UPVCC实壁排水水管,粘接接连接。卫卫生间污水水立管、专专用通气管管采用柔性性铸铁管,WW卡箍连接接。其交叉叉作业集中中在预埋与与结构施工工、管道安装与与建筑施工工部份。因因此,施工工过程中应应与土建密密切配合,管管道与墙体体、地坪接接合处细部部处理重点点,适时穿穿插,交叉叉作业,以以保证工程程进度及施施工质量。给排水施工工前期结构构阶段以预预留预埋为为主,后期期以安装为为主。在整整个施工过过程中应与与土建和其其它工种密密切配合,做做到先预埋埋准确,后后安装到位位;先室内内,后室外外;先地上上,后地下;先支吊吊架,后管管道;先分分段,后连连通。以保保证工程进进度及施工工质量。(1)孔洞洞预留、套套管预埋与与主体上升升同步进行行。(2)室内内管道安装装与室内抹抹灰穿插作作业,墙面面抹灰后,插插入立管及及给水进户户支管安装装,楼地面面形成后插插入排水支支管,并加加强管道保保护达到成成品保护要要求。(3)洁具具安装与卫卫生间施工工穿插进行行,并积极极配合土建建进行孔洞洞吊补及关关水试验。(4)室内内埋地管道道安装在地地坪完成前前进行。室室外管道安安装与环境境同步进行行。、施工程程序 安装准备备预留孔洞洞、预埋套套管支架安装立管安装装支管及管管道附件安安装室内埋地地管道安装装室内埋地地管道灌水水功能性试试验管网管道道系统功能能性试验冲洗及消消毒系统调试试系统验收收、主要施施工方法(1)配合合土建预留留、预埋在给排水施施工中,套套管的选择择、定位及及固定,将将直接影响响到管道安安装的质量量及工程进进度,因此此,施工过过程中应根根据施工图图绘制预留留预埋固化化图,注明明预留预埋埋标高位置置、所属系系统及其具具体尺寸,再再核定土建建、结构施施工图,无无误后随土土建进度按按固化图进行行预留预埋埋。开工前应与与土建协商商分清各自自的范围与与责任,以以免发生错错误、遗漏漏。在配合合土建预埋埋作业中,要要进一步核核对位置、尺尺寸,确认认无误后,才才能进入下下一道工序序。在浇灌灌过程中要要有专人监监护,以防防预埋件或或套管移位位或损坏。套管的选选择:用于于填充墙、砼砼墙体、梁梁采用钢套套管,穿越越楼板、穿越屋面面、地下室室外挡墙及及水池采用用刚性防水水套管。预留预埋埋套管的直直径比管道道直径大两两个规格,预预留孔洞的的尺寸如下下表:管道名称给水立管排水立管直径32-50mmm直径70-100mmm直径小于或或等于500mm直径70-100mmm孔洞尺寸(mm)150200150200当预留孔孔洞、预埋埋套管与结结构钢筋发发生矛盾时时,不得随随意损伤钢钢筋,在经经土建技术术人员核验验,采取相相应措施后后再进行安安装固定。在浇灌过过程中要有有专人监护护,以防预预埋件或套套管移位或或损坏。(2)管道道安装管道安装前前应配合土土建检查并并确定预留留孔洞、预预埋套管的的位置及尺尺寸,并检检查支架设设置的合理理性、规范范性、牢固固性,然后后根据工艺艺流程和网网络计划,采采用先室内内,后室外外;先大管管,后小管管;先主管管,后支管管;先支、吊吊架,后安安装的原则则,适时穿穿插,交叉叉作业,当当发生交叉叉矛盾时应应该是:小小管让大管管,无压管管让有压管管,支管让让主管。管管道整齐、简简洁,并力力求管道配配件(如水水龙头、阀阀门、检查查口等)便便于操作,易易于维修。 支架制安安 管卡卡或吊架应应选型合理理,位置准准确,固定定牢靠,接接触紧密。a、塑料管管道的支吊吊架采用与与管道匹配配的配套产产品。b、角钢支支架的断料料切割机锯锯断,禁止止采用氧割割和电弧焊焊断料,支支架的孔眼眼必须在台台钻上加工工,从而保保证支架洁洁净与美观观。c、管道除除按规范间间距设置支支、吊架外外,管道的的各配水点点、受力点点以及穿墙墙支管节点点处,也应应采取可靠靠的固定措措施。d、排水横横管的支吊吊架设置间间距如下表表:管径(mmm)5075100150间距(mmm)50075010001500e、根据设设计按管道道实际标高高走向安装装管道支、托托架,支、托托架按管道道设计坡度度安装,垂垂直管线采采用线坠调调直,水平平采用挂通通线确保平平直。f、生活给给水水平密密集型塑料料管道、水水平排水塑塑料管道、排水铸铁铁管采用金金属吊架。排排水立管每每层距地11.8m设置1个,排水水支管吊架架安装间距距按上表施施工,并在在相宜管道道附件侧设设置吊架。、PP-R塑料给水水管连接a、所有管管道配件应应是甲方指指定产品或或经设计认认可的合格格产品,必必须有卫生生许可证。管管道入场时时,先经工工程监理核核查验收后后方可使用用。b、管道穿穿楼板时,应应设置刚性性套管,卫卫生间和厨厨房套管高高出地面550mm,其其余穿楼板板钢套管高高出地面220mm,并有有防水措施施。管道穿穿越屋面时时,应采取取严格的防防水措施。穿穿越前端应应设固定支支架。穿过过楼板的套套管与管道道之间缝隙隙应用阻燃燃密实材料料和防水油油膏填实,穿穿墙套管与与管道之间间缝隙应用用阻燃密实实材料填实实,端面光光滑。管道道的接头不不得设在套套管内。c、管道安安装时,不不得有轴向向扭曲,穿穿墙或穿楼楼板时,不不宜强制校校正,给水水管与其它它金属管道道平行敷设设时应有一一定的保护护距离,净净距离不宜宜小于1000mm。 d、安装前前,应对管管道及管件件表面进行行清理,然然后按所需需熔接长度度,使用管管剪下料,再再将管子及及管件同时时放在熔接接模头上加加热,并注注意长度及及方向。加加热后,将将管材及管管件脱离熔熔接模头,立立即对接。热熔连接管道的结合面有一均匀的熔接圈,不得出现局部熔瘤或熔接圈凸凹不匀现象。 e、管道管管件安装前前应内部清清理干净,不不得有毛刺刺,锈斑和和污垢,安安装后要加加盖封堵,防止止杂物入内内;f、阀门安安装:阀门门等配件安安装位置应应便于操作作和检修。截截止阀安装装时,应注注意流体流流动方向,应应使管中流流体由下向向上流经阀阀盘。 排水管管连接a、粘接:PVC-UU塑料管采采用专用胶胶水粘接,粘粘接前清除除被粘接面面上的污物物、毛刺,并并用砂纸打打毛。粘接接前应将承承插口进行行试插,试试插深度以以承口长度度的1/222/3为宜宜,并作出出标记,然然后再刷胶胶。刷胶时时,以刷胶胶饱满不流流淌为合格格。涂抹粘粘接剂后,应应在30秒内完完成粘接,插插接过程中中应稍做旋旋转,但不不得转过11/4圈。b、埋地管管道必须进进行灌水试试验,合格格后方可进进行土方回回填,隐蔽蔽回填时,应应注意管道道成品保护护,防止管管道受损。c、材料质质量要求:安装前应应对管材外外观和管接接头配合的的公差进行行仔细检查查,管材内内外表层应应光滑,无无裂纹、迹迹印,管壁壁薄厚均匀匀,色泽一一致,管件件造型规则则、光滑。d、管道切切割:应采采用专用切切割工具进进行,切割割断面要平平齐,与管管轴方向垂垂直,之后后用铣刀或或刮刀除掉掉断口内外外飞刺。e、管道连连接:PVVC-U管管的连接采采用专用管管件粘接,管管子与管件件对口面应应平行,管管子插入管管件内芯底底部时应轴轴向一致。涂涂抹胶粘剂剂应使用鬃鬃刷或尼龙龙刷,先刷刷承口、后后刷插口,涂涂抹承口应应由里向外外,涂抹粘粘接剂要涂涂均匀、并并适量,涂涂抹粘接剂剂接后应在在20秒内完完成接,粘粘接完成之之后清除接接剂。柔性性铸铁排水水管采用与与铸铁排水水管相配套套厂家的专专用管件连连接。 f、排水水横管与立立管、横管管与横管的的连接应采采用45°三通或四四通和900°斜三通式式四通,不不得采用990°正三通或或四通。PPVC-UU排水管每每层应安装装伸缩节,横横管每4mm应安装伸伸缩节(如如下图)。 g、排水水立管安装装前,应自自上而下挂挂一根垂直直通线检查查,楼层预预留孔洞,并并进行支架架安装后进进行立干管管安装,根根据设计在在有水平分分支处留三三通口,采采用挂水平平线的方法法检查预留留三通口的的标高、位位置、方向向、坡度,确确保准确无无误,为水水平支管安安装创造好好条件。h、排水支支管:支管管安装先搭搭好架子,将将托架按坡坡度栽好,或或栽好吊卡卡,量准吊吊杆尺寸,将将预制好的的管道托到到架子上,接接口处进行行粘接连接接。同时调调整坡度,合合适后固定定支架,封封闭各预留留管口。排排水支管安安装不允许许有倒坡、平平坡的现象象。i、污水管管起点的清清扫口与管管道相垂直直的墙面间间距不得小小于2000mm集水井压压力排水管管道安装焊接管道安安装后应刷刷红丹2道道防锈漆11道,焊接接应饱满。安安装完成后后刷面漆11道。(1)管道道附件安装装a、阀门、压压力表、等等配件安装装位置应便便于操作和和检修。b、止回阀阀有严格的的方向性,安安装时要注注意阀体所所标介质的的流动方向向。 (4)管管网功能试试验管道系统统施工完毕毕,并符合合设计要求求和管道安安装施工有有关规定,支支、吊架安安装正确,牢牢固可靠,在在补涂漆且且具备试验验条件后,才才能进行管管道水压试试验。试验验时、应将将不能参与与试验的系系统、设备备、仪表及及管道附件件等加以隔隔离,加置置盲板的部部位应有明明显的标记记和记录。管道安装完完毕后,给给水管道应应进行水压压试验,排排水管道应应进行通球球、灌水试试验。给水水管道试验验使用介质质为自来水水,试验设设备采用电电动试压泵泵以提高试试验速度。管管道试验应应以独立系系统为单位位,分别试试验。生活活给水管道道试验压力力为工作压压力的1.5倍, 压力试验验生活给水水管道最高高压力处不不低于0.6Mpaa,分二次次升压至试试验压力,然然后稳压11,压力力降以不超超过0.005Mpaa,然后降降至工作压压力1.115倍稳压压2,压压力降以不不超过0.03Mpa为合合格,同时时全面检查查各连接处处不得渗漏漏。排水管管道的通球球试验立管管采用橡胶胶球检查管管道是否畅畅通,通球球球径不小小于管道的的23。排排水支管采采用充气橡橡胶球,以以每层为单单位,堵住住排水立管管,然后向向管内注满满水至最低低排水口55min ,全全面观察以以不漏不渗渗为合格。给给排水管试试验时,均均必须事先先请建设单单位现场代代表参加,并并作好试验验记录及时时办理中间间验收手续续。试验步骤骤如下:管道系统注注水时,先先打开管道道各高处的的排气阀,将将空气排尽尽,待水灌灌满后,关关闭排气阀阀和进水阀阀,用电动动试压泵加加压。从低处进水水,最高处处放空,利利于清除系系统中积余余空气,不不影响试压压。反之,系系统中积有有空气,会会影响试压压的进行,甚甚至由于空空气的可压压缩性,还还导致压力力表读数失失真。每次次试压系统统上至少应应设置2个个校验合格格的压力表表,其中11个设置在在试验泵出出口处,另另一个设在在系统管道道上,读数数应以系统统上压力表表为准。试验升压应应缓慢进行行,不宜过过快。当升升至试验压压力时,停停泵稳压55min,如如无压力下下现象,接接着缓降至至工作压力力,并在稳稳压下进行行全面检查查,如无泄泄漏,表压压力下降不不大于0. 05Mppa为合格格。但在试试验压力下下不能长期期停留。必必须按规范范的要求实实施,在试试验压力下下只能保持持5minn,降至工工作压力后后进行检查查。试压结束束放水时,应应先打开最最高点阀门门卸压,然然后再开下下部放水阀阀排水,以以免系统内内形成负压压遭受损坏坏。排水应应用塑料管管连接排至至合适地点点,不能随随意排放在在施工场所所。(5) 管管道清洗为了保证清清洗干净,应应按管道系系统布置的的实际状况况分段进行行吹洗,吹吹洗顺序应应按主管、支支管、疏排排管依次进进行。管道道吹洗的介介质应按卫卫生系统的的标准、规规范和设计计要求选择择。冲洗时时应以管内内可达到的的最大压力力和流量进进行,冲洗洗应连续进进行。给水管道道系统在验验收前,应应进行通水水冲洗,冲冲洗流速宜宜不大于22ms,冲洗时时,应不留留死角,每每个配水点点龙头均应应打开,系系统最低点点应设放水水口,清洗洗时间控制制在冲洗出出口处排水水的水质与与进水相当当为宜。生活饮用用水系统经经冲洗后,还还应用含22030mggL游离氯的的水灌满管管道进行水水消毒,含含氯水在管管中应滞留留24h以上上。管道消毒毒后,再用用饮用水冲冲洗,合格格后方可交交付使用。四、电气安安装施工1、施工布布署本工程电气气施工顺序序按预埋线线管桥架安装装配线电气设备备器具安装装、系统调试试逐项进行行,同时做做好防雷和和安全接地地的施工。主主体阶段加加强与土建建配合,做做到线管敷敷设及时,到到位准确;安装阶段段做到工序序穿插合理理,交叉调调整得当。()防雷雷接地、线线管(盒)敷敷设与主体体上升同步步施工。()二次次预埋线管管(盒)敷敷设与砖砌砌体同步施施工。()电气气器具在装装饰最后一一道涂料前前插入。2、施工穿穿插()防雷雷接地、线线管(盒)敷敷设与主体体上升同步步施工。()二次次预埋线管管(盒)敷敷设与砖砌砌体同步施施工。3、施工程程序安装准备防雷、线线管预埋桥架安装装配电箱线缆敷设设绝缘测试试电气设备备、器具安安装系统调试试4、施工方方法一> 防防雷接地安安装本本工程防雷雷接地利用用基础地梁梁内大于10主筋通通长焊接作作接地体,无无地梁时采采用40*4热镀锌锌扁钢焊接接连通作接接地体,利利用柱内两两根16钢筋通通长焊接作作引下线,小小于16钢筋焊焊接4根作作引下线,若柱主筋筋采用螺纹纹连接,则则采用12圆钢跨跨接,焊接接长度单面面焊12、双面焊6。利用梁筋筋和引下线线柱筋焊接接25*44热镀锌扁扁钢引出作作卫生间等等电位,梁梁钢筋与镀镀锌扁钢焊焊接长度3倍扁钢钢宽度,330米以上上利用外侧侧梁筋和引引下线焊接接连通作防雷雷均压环,利利用防雷均均压环焊接接出10热镀锌锌圆钢作外外墙门窗和和栏杆防雷雷,焊接长长度单面焊焊12、双面焊6,沿沿电梯井、强强弱电气井井、水井通长长焊接1根根40*44镀锌扁钢钢作井内强强弱电器接接地母线,屋屋面避雷网网格采用梁梁钢筋焊接接成不大于于5m*5m或6m*4m网格,沿沿女儿墙敷敷设12镀锌锌圆钢避雷雷带,屋面面女儿墙阳阳角设置5500mmm高避雷短短针。圆圆钢与圆钢钢的搭接长长度应大于于6倍钢筋直直径,扁铁铁与扁铁搭搭接长度大大于3倍扁扁铁宽度,避避雷线均采采用焊接,搭搭接焊时,先先将搭接处处的铁锈除除去,其圆圆钢和扁钢钢焊接时,搭搭接长度大大于6倍钢筋直直径,钢筋筋双面焊接接;扁铁33边焊接,焊焊缝饱满并并有足够的的机械强度度,无夹渣渣、虚焊,焊焊后清出焊焊渣。在在基础接地地施工完毕毕后,应做做好隐蔽资资料,并进进行接地电电阻预测,合合格后,请请有关单位位签证认可可。二> 配配管施工线管(盒)安安装是本工工程电气施施工的关键键。施工前前应结合施施工图纸,绘绘制实际线线管布置图图,以指导导施工。施施工过程中中,抓 住住 现 浇浇 板、柱柱子、墙 体 三 大 部 位,加 强 与 土建配合合,进行交交叉作业;加强各部部 位线管管(盒)的的联接处理理,保证线线管敷设整整体性、连连贯性,从从而达到线线管到位及及时,敷设设准确,管管盒畅通。 砖墙体体内线管在在砖砌筑后后开槽埋入入,保护厚厚度不小于于2.5mm,线盒在在砌体形成成,抹灰插插入前安装装就位,从从而保证线线盒方正,标标高误差符符合规范要要求。接线线盒安装的的重点在于于标高的控控制,首先先联系土建建,确定地地坪厚度,然然后确定标标高,安装装线盒。板内线管管与墙体内内线管的连连接,可适适当采取在在板内或墙墙体内增设设转线盒加加以实现,以以利于穿线线,便于维维护。 暗埋PPVC线管管的保护层层厚度不得得小于300mm,钢管管的保护层层厚度不得得小于155mm。线管管的弯曲半半径一般不不小于122倍管外径径,若条件件限制,最最小不得小小于6倍管管外径。 电气配配管进盒、箱箱顺直,必必须一管一一孔。 三> 电电线施工 管内穿穿线宜在建建筑物抹灰灰、粉刷工工程结束后后进行;穿穿线前,应应将电线保保护管内的的积水及杂杂物清除干干净。 导线连连接采用安安全型压接接帽压接或或绞接后涮涮锡,并确确保牢固、密密实和检修修方便。接接线过程中中及时做好好绝缘电阻阻的测试。 不同系系统、电压压,不同电电流类别的的线路,不不能穿在同同一管内。管管内导线不不得接头,受受挤压,接接头应设在在接线盒、箱箱内。 导线必必须按相分分色,不得得混用,LL1相用黄黄色,L22相用绿色色,L3相用红红色,中性性线N用浅兰色色。保护地地线(PEE线)采用黄绿绿相间的双双色线。 管内穿穿线:穿线线时,先在在管内打丝丝。检查管管路是否畅畅通,管路走向、箱箱、盒位置置是否符合合设计及施施工图。打打丝用1.22.0mmm的钢丝丝,先将钢钢丝的一端端弯成不封封口的圆圈圈,再利用用穿线器将将钢丝穿入入管内,若若打丝受阻阻则用两根根钢丝同时时搅动,使使两根钢丝丝的端头钩钩在一起,然然后将其拉拉出。若同一管路路内只有223根导线时时,可将导导线前端的的绝缘层削削去,然后后将线芯直直接插入钢钢丝的盘圈圈内并折后后压实、绑绑扎牢固。使使绑处形成成一个平滑滑的锥形,管管路另一端端则用力均均匀拉动。若若同一管路路内有4根或更多多导线需穿穿时,则将将导线前端端的绝缘层层削去,然然后将线芯芯斜错排列列在铁丝上上,用扎丝丝绑扎牢固固,管路另另一端则用用力均匀拉拉动。 绝缘测测试首先采用5500V,量量程0500MM的兆欧表表进行绝缘缘摇测。采采用万用表表检查导线线是否为通通路,检查查导线连接接,包扎是是否符合规规范,再进进行互检,无无误后方可可进行绝缘缘摇测。绝缘测试前前,将灯头头、插座盒内内导线分开开,开关盒盒内导线连连通,摇测测时干线、支支线分别摇摇测。摇动动速度要保保持在1220转/minn左右,采采取一人摇摇测,一人人读数并记记录。 五、桥架、电电缆施工: 直线段电电缆桥架长长度超过330米设伸伸缩节,电电缆桥架跨跨建筑变形形缝处设伸伸缩节。电电缆桥架水水平安装的的支架间距距为1.55m,垂直直安装的支支架间距不不大于2m,桥架架与支架、桥桥架与桥架架连接紧固固螺栓无遗遗漏,螺母母位于桥架架外侧。敷敷设在竖井井内和穿越越不同放火火区的桥架架,应按设设计要求防防火隔堵。 金属电电缆桥架及及其支架和和引入或引引出的金属属电缆导管管必须接地地。 金属电电缆桥架及及其支架全全长应不少少于2处与与接地(PPE)干线线相连接。 金属电电缆桥架两两端跨接铜铜芯接地线线,接地线线最小允许许截面积不不小于4²。 大于445倾斜敷敷设的电缆缆每隔2mm设固定点点,电缆出出入电缆沟沟、竖井、建建筑物、柜柜(盘)及及管子管口口处等做密密封处理。电缆敷设设应排列整整齐,水平平敷设的电电缆首尾两两端、转弯弯两侧及每每隔5110米设固固定点。电电缆首尾两两端和分之之处应设标标志牌。六、动力、照照明配电箱箱(盘)安安装动力、照照明配电箱箱(盘)安安装牢固,垂垂直度偏差差不大于11.5,箱内接线整整齐,回路路编号齐全全,标识正正确。 箱内导导线连接紧紧密,不伤伤芯,不断断股。同一一端子上导导线连接不不多余2根根。箱(盘)内内开关动作作灵活,漏漏电保护开开关动作电电流不大于于30mAA,动作时时间不大于于0.1。七、 灯具具、开关、插插座的安装装灯具重量量大于3时,应固固定在螺栓栓或预埋吊吊钩上,灯灯具应固定定可靠。当灯具距距地面高度度小于2.4m时,灯灯具的可接接近裸露导导体必须接接地(PEE)可靠,并并应有专用用接地螺栓栓,且有标标识。应急照明明灯的电源源除正常电电源外,另另有一路发发电机电源源。安全出出口疏散标标志灯安装装在门上方方0.2米米,走道和和楼梯间疏疏散标志灯灯安装在0.5m的墙墙上。单相两孔孔插座,面面对插座右右孔或上孔孔接相线,面面对插座左左孔或下孔孔接零线。单相三孔孔、三相四四孔及三相相五孔插座座的接地(PPE)保护护线接在上上孔。同一一场所的三三相插座,接接线相序应应一致。插插座的接地地(PE)保保护线接在在插座间不不串联连接接。八、劳动力力计划劳 动 力 情 况况工种、级别别基础主 体装 饰焊 工432电 工2315管道工1310施工员111质检员111安装技术负负责人111安装资料员员111安装材料员员111九、主要施施工机具计计划名 称 类 别数量交 流 电电 焊 机机5台台 钻3台PPR管管 热 熔熔 机 具具6套砂 能 切切 割 机机3台电 钻 5台电 动 试试 压 泵泵1台万用表只量程05500M兆欧表1只地 阻 仪1只电 锤10台十、保证工工程质量 防止质质量通病措措施(一)、严严格执行国国家强制性性标准及行行业标准我司将在施施工中将严严格执行现现行国家新新施工规范范(GB系系列)、新新规程(JJGJ系列列)及行业业强制性标标准质量体体系对其定定义的质量量要素进行行分解细化化,并将质质量职责落落实到每个个人头上。确确保将此工工程建设为为优良工程程,让业主主放心。保证现场每每一个人各各负其责,各各司其职,通通力协作,将将此工程保保质保量地地交给业主主。(二)、工工程质量保保证措施质量是企业业的生命,是是企业的立立足之本。“百年大计计、质量第第一。”我司将从从质量意识识教育上、组组织上、制制度上、施施工各个环环节上,确确保该工程程的施工质质量达到合合格标准。1、组织保保证措施(1)、精精选业务素素质高、管管理工作经经验丰富、责责任感极强强的施工、技技术、质量量、安全、设设备、材料料等人员组组成项目管管理班子,对对各专业施施工有统一一指挥权,对对各工序、工工艺之间的的质量验收收和交叉穿穿插有统一一协调权,确确保工程目目标的实现现。材料负责(材料质量责任人)各专业工长(单项质量责任人)材料员(入场质量责任人)班组质检员项目经理(质量责任)人)质检负责(工程质量责任人)施工负责(施工质量责任人)技术负责(技术质量责任人)内业技术(资料质量责任人)质检员(专职质量责任人)(2)、项项目经理必必须懂技术术、善管理理、重质量量、与项目目的技术负负责、施工工负责、质质检负责、材材料负责组组成严格过过硬、奖罚罚严明的质质量保证体体系(详项项目质量保保证组织机机构图),确确保项目各各类人员在在组织行动动方面、上上岗尽职方方面、分工工合作方面面、保证质质量及进度度目标方面面等,从组组织管理措措施上落实实到位。项目质量保保证组织机机构图 (3)、专专职质检人人员,在班班组自检、互互检、交接接检的基础础上,独立立行使质量量监督职能能,赋予质质量否决权权,严格监监督生产班班组和分配配同质量挂挂钩,其优优质工资的的多少、有有无,必须须经专职质质检人员检检查、认可可、签证后后方可发放放,专职质质检员直接接向项目经经理负责。2、技术保保证措施(1)、认认真阅读设设计图纸,较较好地完成成设计交底底,并根据据设计图说说明、交底底纪要、规规程及规范范,有针对对性地编制制出切实可可行的施工工设计方案案。(2)、施施工过程中中的工序控控制是保证证工程质量量的科学方方法,它的的基本特点点是从过去去的事后检检验把关为为主转变为为预防和改改进为主,从从管结果变变为管因素素。工序控控制是要使使整个工程程的施工过过程都处于于受控状态态。(3)、建建立严格的的隐蔽工程程检查制度度。 凡属隐蔽蔽工程项目目,应先由由班组、项项目部逐级级自检,自自检合格后后,会同业业主驻现场场代表或监监理部门一一起复检,将将检查结果果填入验收收表格,双双方签字签签发隐蔽工工程验收资资料。3、现场材材料质量管管理措施(1)、严严格控制外外加工、采采购材料的的质量a 各类安安装材料到到现场后必必须查验,核核对质量保保证资料,并并按规定进进行抽样检检查,无检检测合格证证明的材料料严禁使用用。b 凡是对对装修效果果、使用安安全等有影影响的材料料,必须按按设计说明明和有关规规范要求,由由建设方、施施工方及有有关单位一一道看样、比比选、定质质、定价后后才能采购购。4、坚持样样板制,保保证整体施施工质量在室内安装装施工前,必必须坚持样样板施工制制度,经建建设方、设设计方及监监理部会同同有关部门门对样板检检查验收合合格后,方方可大面积积施工。同同时,坚持持作到样板板带路,跟跟样施工,从从而保证整整体施工质质量。5、定期质质量分析,实实施动态管管理各分部分项项工程施工工前,组织织班组技术术交底,除除对工艺流流程、施工工重点、质质量要求等等作详细交交底外,应应强调对重重点、难点点部位的施施工必须按按全面质量量管理方法法,建立质质量管理点点,定期作作施工质量量分析,实实施工程质质量动态管管理。(三)、安安装质量通通病防治措措施(1)墙面面预留线盒盒洞不当造造成的空鼓鼓,一般墙墙面的开关关,插座盒盒洞的抹灰灰往往预留留偏大,且且安装完线线盒后的堵堵洞和抹灰灰,往往由由电工来完完成,这使使造成了线线盒四周堵堵塞不严、不不实、不平平且空鼓裂裂缝,解决决办法:a墙中应预预留的线盒盒,应由技技术员、施施工员测量量准确线盒盒的定位尺尺寸,盒洞洞周围注明明形状和尺尺寸。b 抹抹线盒洞时时,先用碎碎砖按照预预留形状和和尺寸堵补补且砖浇透透水。c 如线线盒洞砌体体时预留基基本准确但但仍偏大330-400mm时可可以水泥砂砂浆分两次次堵补。d 应由由抹灰工按按正确的方方法修补。e 顶棚棚灰面与线线盒部位应应顺通,抹抹后用2mm靠尺检查查,杜绝局局部不平整