SM系统硬件介绍-PPT.ppt
SM系统硬件介绍1Safety Manager system2SM ControllerThe SM Controller is installed in the Controller chassis.Safety Manager system3The SM Controller is NON REDUNDANT,containing one Control Processor.OR.SM ControllerSafety Manager system4SM Controller.REDUNDANT containing two Control ProcessorsSafety Manager system5IO ChassisSafety Manager system6IO ChassisIO ChassisMaximum 8 IO chassisSafety Manager system7IO ChassisIO ChassisMaximum 9 IO chassisSafety Manager system8大家有疑问的,可以询问和交流可以互相讨论下,但要小声点 可以互相讨论下,但要小声点9Maximum Safety Manager system,consists of 4 cabinets.Safety Manager system10Maximum Safety Manager system,consists of 4 cabinets.Max.distance Max.distance allowed allowed between between Controller and Controller and IO modules is 2 IO modules is 2 cabinets cabinetsSafety Manager system11Picture controllerSM Controller12Picture controllerSM Redundant Controller13SM Non Redundant Controller14Picture controllerControl Processor15Quad Processor Pack(QPP-0002)16Quad Processor Pack(QPP-0002)17Quad Processor Pack(QPP-0002)Functionalities:2 processors(1oo2D)18Quad Processor Pack(QPP-0002)Functionalities:2 processors(1oo2D)Watchdog(1oo2D)19Quad Processor Pack(QPP-0002)Functionalities:2 processors(1oo2D)Watchdog(1oo2D)4 IO Controllers20Quad Processor Pack(QPP-0002)Functionalities:2 processors(1oo2D)Watchdog(1oo2D)4 IO Controllers User interface21Universal Safety Interface(USI-0001)22Universal Safety Interface(USI-0001)23Universal Safety Interface(USI-0001)24Tx&Rx LEDsUniversal Safety Interface(USI-0001)25Communication types Channels A&B-Ethernet connection26Communication types Channels A&B-Ethernet connectionCommunication Solutions CEE Controller(Fault Tolerant Ethernet);Experion PKS server(Fault Tolerant Ethernet);External Clock source device;Modbus RTU;Safenet;Safety Station;SOE.27Communication types Channels C&D-RS-232 or RS-485 connection28Communication types Channels C&D-RS-232 or RS-485 connectionCommunication Solutions Modbus;Safenet;Safety Station;295Vdc Power Supply Unit(PSU)305Vdc Power Supply Unit(PSU)31Safety Manager Controller32Battery and Key switch Module(BKM-0001)33Reset keyBattery and Keyswitch Module(BKM-0001)34Force enableBattery and Keyswitch Module(BKM-0001)35Force enableBattery and Keyswitch Module(BKM-0001)36Battery and Keyswitch Module(BKM-0001)37IO chassis38IO chassis An IO chassis can contain up to 18 IO modules;Different types of IO can be mixed in IO chassis One type of external power per IO chassis;An IO chassis is either for Redundant or Non Redundant IO.39IO module types 40IO module types Digital Input modules41IO module types Digital Input modules Analog Input modules42IO module types Digital Input modules Analog Input modules Digital Output modules43IO module types Digital Input modules Analog Input modules Digital Output modules Analog Output module444546474849Field Termination Assembly(FTA)50 3.3.How are the hardware components linked within the system?51Controller Chassis5253I/O bus54I/O busTo next I/O chassisI/O bus55I/O busI/O busFS-SICC-0001FTATo next I/O chassis562.2.3.3.I/O bus I/O bus1.1.Internal 24V Internal 24Vpower supply power supply CPs CPsTo next I/O chassis To next I/O chassisExternal power supply External power supplyTo User Stations To User Stations HSE HSE Ethernet EthernetSwitches SwitchesTo ToPlant PlantEthernet EthernetComFta ComFtaRS485 RS485I/O bus I/O bus24 24 Vdc Vdc 24 24 Vdc Vdc power supply rail2.2.3.3.WD and 5 WD and 5 Vdc Vdc WD and 5 Wd and 5 Vdc Vdc connection cablesI/O bus I/O bus1.1.Internal 24V Internal 24Vpower supply power supply CPs CPsTo next I/O chassis To next I/O chassisExternal power supply External power supplyInternal power supplyTo User Stations To User Stations HSE HSE Ethernet EthernetSwitches SwitchesTo ToPlant PlantEthernet EthernetComFta ComFtaRS485 RS485FTA FTA FTA FTAI/O bus I/O bus=IO busses=5Vdc&Watchdog wiring=24Vdc wiring=SIC cables=Communication wiringFS-SICC-0001575859601200 S 24 P067 power supply611200 S 48 P067 power supply6263