1、精选优质文档-倾情为你奉上工程材料验收标准(安装工程)专心-专注-专业编制单位:安装公司工程部编制日期: 2014 年 6 月 25 日建筑工程材料验收控制标准目录第一部分通用类 .3第一章管材 .31.1焊管、镀锌管 .31.2无缝钢管 .3第二章型材 .42.1角钢 .42.2钢板 .62.3槽钢 .7第二部分 电气类 .8第一章主材 .81.1镀锌扁钢 .81.2PVC 管 .91.3桥架 .91.4金属软管 .111.5电线、电缆 .111.6灯具 .151.7配电箱 .151.8母线槽 .161.9开关、插座、接线盒 .161.10灯座 .171.11防火包 .17第二章辅材 .17
2、2.1防水胶布 .172.2电焊条 .172.3黑胶布 .182.4PVC 胶粘剂 .182.5铜线鼻子 .182.6压线帽 .19第三部分给排水 .19第一章主材 .191.1AGR 管 .191.2柔性接口铸铁管 .201.3灰铸铁管 .211.4PP-R 管 .211.5给水衬塑复合钢管 .231.6PVC U 管 .23第1页共51页1.7铜管241.8薄壁不锈钢管251.9PE 给水管261.10地漏281.11法兰281.12卫生陶瓷291.13给水水箱311.14水表311.15臭氧消毒器331.16水流指示器331.17蝶阀331.18截止阀331.19减压阀341.20浮球阀
3、351.21球阀351.22闸阀36第二章辅材372.1PVC U 管件372.2灰口铸铁管件382.3柔性铸铁管件39第四部分采暖与通风空调39第一章主材391.1PERT 管391.2PEX 管401.3PB 管411.4玻璃钢风管421.6波纹金属软管441.7苯板451.8挤塑板风管451.9风口461.10消声器471.11散热器471.12换热器481.13冷却塔481.14轴流风机491.15直燃机组491.16排烟防火阀501.17调节阀501.18通风蝶阀511.29风机盘管51第2页共51页第一部分通用类第一章管材1.1焊管、镀锌管一、焊接钢管:执行国家GB/T13793-
4、2001 标准热镀锌管:执行国家GB/T3091-2001 标准二、产品应用于水、污水、燃气、空气、采暖蒸气等低压流体输送和结构用的直缝焊接钢管。三、国标产品系列:长度:定尺6米/支焊管、镀锌管米重表表 1.1型号公称口径规格 /mm焊管镀锌管每件支数 ()/mm/in(外径 * 壁厚)国标米重 Kg/m国标米重 Kg/mDN154 分21.3*2.751.261.34217 支/ 件DN206 分26.8*2.751.631.73169 支/ 件DN251 寸33.5*3.252.422.57127 支/ 件DN321.2寸42.3*3.253.133.3291支/件DN401.5寸48*3
5、.53.844.0791支/件DN502 寸60*3.54.885.1761支/件DN652.5寸75.5*3.756.647.0437支/件DN803 寸88.5*4.08.348.8437支/件DN1004 寸114*4.010.8511.5019支/件DN1255 寸140*4.515.0415.9419支/件DN1506 寸165*4.517.8118.8819支/件DN2008 寸219*6.031.5233.417支/件四、验收方法:1、外观检查:壁厚均匀,管口无毛刺,无锈蚀,弯折现象;整件包装完好;2、测量:用游标卡尺测量壁厚,用卷尺测量长度。用电子秤或磅秤测量重量。3、试验方法
6、:电线管抽样检测 DN15 20,用弯管器现场煨弯,弯曲度和弯扁度符合要求;热镀锌管用锤适当敲外壁,观看是否有缝隙。4、资料要求:随车附带相应规格的产品质量证明书。1.2无缝钢管一、无缝钢管:执行国家GB/T17395-1998 标准。二、型号与规格:无缝钢管型号与规格表 1.2壁厚mm外径2.02.22.52.83.03.23.54.04.55.0mm理论重量kg/m502.372.592.933.253.483.704.014.545.055.55第3页共51页512.422.642.993.323.553.794.104.645.165.67532.522.763.113.463.703
7、.944.274.835.385.92542.562.813.183.533.774.024.364.935.496.04562.662.923.303.663.924.174.535.135.716.29572.712.973.363.744.004.254.625.235.836.41602.863.133.553.944.224.494.885.526.166.78633.013.303.724.154.444.735.135.816.497.14653.113.403.854.294.594.895.316.026.717.40683.263.574.044.494.815.125.5
8、76.317.057.77703.353.684.164.364.965.235.746.517.278.01733.503.844.354.845.185.526.006.817.608.38753.603.954.464.975.325.686.177.007.828.62763.654.004.535.055.405.756.267.107.938.75803.844.224.775.325.696.076.607.498.379.24834.004.374.965.525.926.316.867.798.719.62854.094.485.085.666.066.467.047.988
9、.939.83894.294.705.335.946.366.777.388.389.3810.33904.344.765.396.016.436.867.478.479.4910.47954.595.025.706.366.817.267.908.9810.0411.101004.835.306.006.707.177.658.329.4610.5911.701024.935.406.136.847.327.818.509.6710.8211.961085.235.746.507.257.778.299.0210.2611.4912.701105.325.846.627.397.928.43
10、9.1910.4611.7012.931205.836.387.248.078.669.2210.0611.4412.9314.301256.066.647.548.429.029.6110.5011.9113.3714.801307.868.789.4010.0010.9212.4313.9215.481338.058.989.5910.2511.1812.7514.2615.7514010.1110.7911.8013.4215.0516.6515010.8511.5212.6514.3916.1117.85三、验收方法:1、外观检查:壁厚均匀,管口无毛刺,无锈蚀,弯折现象;整件包装完好;
11、2、测量:用游标卡尺测量壁厚,用卷尺测量长度。用电子秤或磅秤测量重量。3、试验方法:抽样检测。4、资料要求:随车附带相应规格的产品质量证明书。第二章型材2.1角钢一、角钢:执行GB 9787-88 、GB 9788-88 标准。二、型号与规格:等边角钢的规格与尺寸(b-边宽; d-边厚; r- 内圆弧半径)表 2.1尺寸(mm )截面面积理论重量外表面积角钢号数dr(cm 2 )(kg/m)(m2 /m)b22031.1320.8890.07843.51.4591.1450.0772.52531.4321.1240.098第4页共51页41.8591.4590.09733031.7491.37