1、 11、汽轮机型式及参数汽机型式为一次中间再热、亚临界、单轴、双缸、双排汽、冲动凝汽式汽轮机,额定功率为 352MW,额定主蒸汽参数:P0=17.46Mpa,t0=538;额定再热蒸汽参数:Prh=3.07Mpa,trh=538;额定排汽压力 Pc=0.0049Mpa; hc=2371kj/kg。2、锅炉型式及参数锅炉型式为露天布置、平衡通风,具有平行尾部通道的燃煤辐射锅炉;单汽包、单炉膛、具有一次中间再热的亚临界自然循环锅炉;额定蒸发量为1085.1t/h,额定饱和蒸汽压力 19.02Mpa,过热蒸汽压力 17.84Mpa,过热蒸汽温度 540.6,再热蒸汽温度 539,给水温度 282,锅
2、炉效率为 93.7%。3、回热系统及参数机组采用八级回热(三高加四低加一除氧) 。额定工况下的抽汽参数:#1 高加#2 高加#3 高加除氧器#5 低加#6 低加#7 低加#8 低加抽汽1 2 3 4 5 6 7 8压力MPa6.773.351.830.850.410.190.0750.0309温度 40030245735726518598702除氧器滑压运行,凝泵出水压力为 2.15Mpa,采用汽轮给水泵,汽源与除氧器同为四抽蒸汽,额定蒸汽参数为:hDT=31774kj/kg,;MPapcDT005. 0kgkjhcDT/2440小汽机的耗汽量占给水流量的份额;小汽机排汽至冷凝器;给水泵出口压
3、03376. 0DT力为 20.43 Mpa。、其它数据的选取主机、给泵汽机合用同一轴封汽系统;额定负荷时,由于系统采用自密封型式,高压缸前轴封漏汽通过一只汽动调阀回收到四抽;轴封母管过剩汽通过三通转换阀至#1低加汽侧回收;高压部分轴封漏汽经冷凝器冷却后供低压轴封;由轴加建立的微真空抽出汽缸轴封漏汽加热凝泵出口的凝水,由于轴封汽参数取用困难,因此在热力计算中省略了轴封漏汽部分计算,考虑到与系统实际运行可能出现计算偏差,在热力系统计算中考虑了轴封漏汽的加热量,根据实际运行数据,取#1 低加进口水温为 37.5。汽轮发电机组的机械效率 M=0.995发电效率 g=0.995管道效率 p=0.995
4、、原始数据整理锅炉出口蒸汽参数 P0=17.84Mpa,t0=540.6,取新汽压损为 3%,故汽机进口蒸汽参数为 P0=17.3Mpa,t0=538;高压缸排汽口压力 3.35Mpa,再热蒸汽压损为10%,中压缸进汽参数 Prh=3.02Mpa,trh=538;中低压缸联通管压损取 2%,低压缸进汽压力 PL=0.83Mpa,在焓熵图上作该机组的汽态线:4200021002200230024002500260027002800290030003100320033003400350036003700380039004000410042005.05.56.06.57.07.58.08.59.05
5、.05.56.06.57.07.58.08.59.020002100220023002400250026002700280029003000310032003300340035003600370038003900400041004200h KJ/kgKJ/kgKJ/kgKGE352MW机组的汽态线0.005pDTc2440hDTc2371hc0.0049pc70t8 80.0309p82627h82675h798t770.075p7185t6 60.19p62841h60.41p5265t5 5 2995h5357t4 440.83p20.85p43177h4457t333376h323540
6、hrh540t0 538t017.84P017.3P03388h03168h12990h212400t1302t23.35p26.77p1100MP机组各计算点参数表:5抽汽口加热器汽侧加热器水侧计 算 点设备pj MPatjhj kj/kgPj MPatsj tdj hdj kj/kgqj kj/kgQj Pwj MPatwj hwjkj/kgj kj/kgj kj/kg017.435403388.6017.35383388.61H 86.644002115.46.64282.3243.11052.72115.40.320.432821241.3209.112H 73.33022104.33
7、.3239.2207.4886.42104.31.220.432381031.6163116.323.025383540.53H 61.754572608.81.75205.8180.9767.52608.84.020.43201.8868.6115.5118.94 小 汽 机 除 氧 器0.85 3.57 3177.4 0.781702579.40.78171.9728.2130.25H 40.412652995.40.398143.4120.3505.12490.31.62.15141.8598115.4169.56H 30.191852841.10.182117.393.1390.124
8、512.62.15108.7482.6113.81157H 20.075982675.80.07290.690.2377.822983.42.1587.2366.888.412.38H 10.0397026270.03569.638.9162.92464.13.52.1566.1278.4119.5CC0.04932.523712.1537.5158.9注:考虑给水泵焓升;#3 低加进口水焓取 368.8kj/kg;#1 低加进口水温考虑轴封漏汽加热取 37.5系统热经济性计算系统热经济性计算各加热器抽汽放热量 qj的计算6kgkjhhqd/8 .21077 .10525 .3160111kg