RoHS环保测试仪作业指导书(共4页).doc
《RoHS环保测试仪作业指导书(共4页).doc》由会员分享,可在线阅读,更多相关《RoHS环保测试仪作业指导书(共4页).doc(4页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、精选优质文档-倾情为你奉上RoHS环保测试仪作业指导书RoHS environmental testing working instruction班级: 姓名: 学号一 目的purpose:为正确使用仪器,避免因不当使用导致仪器损坏,确保仪器使用寿命及测试准确度。 For the proper use of equipment, avoid the improper use of cause equipment damage, ensure the service life of the apparatus and testing accuracy.二范围Range: 用于进料、制程、出货阶段
2、之( 原物料、辅材、半成品、成品等 )环境有害物质检测分析。 For feed, process, ship stage (raw materials, semi-finished products, finished products such as auxiliary, environmental hazardous substances testing analysis).三权责Responsibilities:3.1. 仪校人员负责操作指导书制定。 3.1. Instrument school personnel responsible for operating instructio
3、ns.3.2. 测试人员负责仪器保养与维护。3.2. The test personnel responsible for the equipment maintenance and maintenance.3.3. 测试人员必须为接受过相关仪器操作培训合格之品保课人员。3.3. The test must have received relevant equipment operation training of qualified quality assurance staff.四 仪器开机与关机顺序Instrument boot and shutdown sequence:4.1. 开机
4、顺序: 开稳压电源 开测试仪(绿灯亮) 开电脑主机 打开测试程序软件。4.1 boot sequence: regulated power supply testing instrument (green light) to open the computer host open test software.4.2. 关机顺序: 退出测试程序软件 关电脑主机 关测试仪 关稳压电源。 4.2. The shutdown sequence: exit test software to turn off the computer shut off power supply tester host.五
5、 指示灯说明Indicator description:5.1. 绿灯-电源指示灯 :打开仪器电源此灯亮。 5.1 - green power indicator: open the instrument power the lights.5.2. 黄灯-运行指示灯:仪器测试运行时此灯亮,测试结束此灯自动熄灭。 5.2 yellow lights - running indicator: instrument test running the lights, the end of the test the lamp is automatically extinguished.六操作流程Oper
6、ation process: 6.1. 每次开机时,首先需对仪器进行预热30分钟,具体预热步骤如下:6.1. When starting up every time, the apparatus for preheating for 30 minutes, the preheating step as follows6.1.1取适量(塑胶样品)放入测试工作台 点击样品图查看样品摆放 点击工具栏 6.1.1 apply (plastic sample) into the testing table click sample to view the sample placed on the too
7、lbar 参数设置设置预热时间(1800) 秒 点击测塑料中Cr Cl测量曲线 点击开始键 输入样品parameters preheat time (1800 seconds) click on the Cr Cl measurement measuring plastic curve click Start button input samples 信息(任意输入), 点击确定预热测量开始(黄灯亮),待1800秒测试时间终止,本次预热即完成。 Information (arbitrary input), click OK to preheat the measurement start (y
8、ellow light), to be 1800 seconds test time expires, the preheating is finished. 6.2. 每次开机后或(仪器测试程序软件关闭后再打开)需测量产品前,必须先用纯银校正片作初始化校正,在此动作顺利通过情况下,方能继续下一步操作。具体初始化步骤如下: 6.2. After each reboot or (instrument testing software is closed and then opened) for measuring product, must first use silver correction
9、 piece as initialization correcting, this moves smoothly through the case, to continue the next operation.The initialization procedure is as follows: 6.2.1选择工具栏参数设置的(初始化)项,按系统提示放入纯银校正片点击OK开始初始化,初始化成功后其状态栏之峰通道需显示为“1105”道,否则需重新进行初始化达到要求为止。 6.2.1 select the toolbars parameters of (initialization), prom
10、pted by the school in sterling silver. Click OK to start the initialization initialization, after the success of the state bar of peak channel need to display as 1105, or the need to initialize meet the required date. 6.3. 样品测试操作步骤如下: 6.3 sample test steps are as follows: 6.3.1测量时间设置:选择工具栏参数设置的(测量时间
11、)项,在出现的对话框中输入时间(单位/秒),点击OK设置完成。(设置时间一般为200秒,若测试不准确时可适当延长测量时间) 6.3.1 measurement time settings: select the toolbars parameters of (measure time), appears in the dialog box input time (units / sec), click on the OK set complete.(setting time is generally 200 seconds, if the result is not accurate when
12、 may be appropriate to extend the time measurement) 6.3.2选择测量曲线:根据被测样品材质(塑胶、有色金属、焊锡、钢铁、镁铝等),从软件界面左边曲线栏选择对应的测试曲线(系统预设)(铜材/镀金品选择有色金属项,镀锡品选择测焊锡项) 6.3.1 measurement time settings: select the toolbars parameters of (measure time), appears in the dialog box input time (units / sec), click on the OK set co
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- RoHS 环保 测试仪 作业 指导书
限制150内