设备防火涂料工程施工方案(共13页).docx
《设备防火涂料工程施工方案(共13页).docx》由会员分享,可在线阅读,更多相关《设备防火涂料工程施工方案(共13页).docx(13页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、精选优质文档-倾情为你奉上设备防火涂料施工方案Method Statement of Fireproof Coating for Equipment NoDateRevisionPreparedCheckedApproved12目 录一、 概述General:本方案为2-PH钢结构和设备防火涂料保护施工制定。This method statement is prepared for the fireproof coating of steel structure and equipment in 2-PH.二、 参照标准Reference Standards:1. GB50160-2008石油
2、化工企业设计防火规范GB50160-2008 “Fire Prevention Code of Petrochemical Enterprise Design” 2. 爆炸和火灾环境电力装置设计规范 GB 50058-92GB 50058-92“Electrical installation design code for explosive atmospheres and fire hazard”3.防火设计说明 “Design Specification for Fireproofing”4. 设备防火一览表 Equipment Fireproof List三、 防火工程范围 Firepr
3、oof Range1防火高度Fireproof Height:设备防火高度应为地基以上7.3米(详见附件1防火一览表)。Surface of equipment shall be fireproofed up to EL 7.3m from grade(see attachment 1 fireproofing list).2防火范围Fireproof Scope:落地钢塔、立式容器的防火构件为钢塔、立式容器的裙座外壁、设备底座、底座锚栓,当钢塔、立式容器的裙座有人孔时,裙座内壁也须做防火。Steel tower and vertical vessel on the ground: steel
4、 column, outer wall of skirt, equipment base, base anchor bolt. If there is manhole at skirt, inner wall of skirt shall also be included.设备裙座人孔 内泛边不做防火,外泛边做防火。For the inner edge of the manhole at skirt of the equipment, fireproof is not required, but the outer edge needs fireproof.3防火材料、防火做法Fireproo
5、f Coating and Preparation:采用厚型防火涂料。Use thick fireproof coating.防火工作结束后对表面涂刷面漆,颜色为RAL 7035,厚度为50um(两遍漆)。Apply the finish coating to the surface after the fireproofing work. Its thickness is over 50um(tow layers), the color of top coating is RAL 7035(light gray) .落地钢塔、立式容器裙座的防火采用挂镀锌钢丝网涂室外厚型防火涂料的做法。Ski
6、rt of floor steel tower and vertical vessel: use outdoor thick fireproofing coating with galvanized steel wire mesh shall be used.4耐火等级与耐火极限Fire Resistance Rating and Fire Endurance:落地钢塔、立式容器设备裙座耐火等级为一级,耐火极限为最小1.5小时。Skirts of floor steel tower and vertical vessel: fire resistance rating shall be Gra
7、de 1 and a minimum fire endurance be 1.5 hours.四、 施工方案 Construction Method材料选用:上海平海涂料有限公司生产的PHASW室外厚型钢结构防火涂料Material Selection: Outdoor thick steel structure fireproofing coating PHASW produced by Shanghai Pinghai Co.Ltd.涂料选用的总体原则说明 General Principle of Painting SelectionA、符合业主工程设计文件钢结构防火涂料方案中对涂料品牌的
8、要求和规定; Meet requirements and regulations for the painting brand in the engineering documents of steel structure fireproof coating by Owner;B、涂层之间有较强的配套性、外观等性能要求; Meet the performance requirements of compatibility and appearance for coatings.C、选用的产品具有较强的施工性能,在符合一切技术要求的前提下,能最大限度地减少施工上的困难和不便; The selec
9、ted product should be feasible to construct, meet all technical requirements and minimize the difficulty and inconvenience in construction.D、在满足性能及其他各项要求的同时,尽可能选用较为经济型的产品,以便合理控制整体工程成本。 The product should be economical while meeting the performance and other requirements, in order to control the whol
10、e project cost reasonably.选用的防火涂料特点介绍Characteristics of the Selected Fireproof Coating: PHA-SW室外钢结构厚型防火涂料防火性能好,耐火极限高,符合一般设计要求;For the outdoor thick fireproofing coating PHASW, the fireproof performance is very good with long fire endurance, which can meet design requirements;粘结强度高:0.04MPaCohesional
11、strength 0.04MPa涂层弹性好,不会开裂或整块脱落失去防火性能。The coating should be resilient, which cannot crack or fall off and lose fireproof performance.(一) 防火涂料耐火时间与施工厚度(见附件1)Comparison Table of Fire Resistance Period and Construction Thickness(see attachment 1) 1) 耐火时间Fire Resistance Period 防火涂料的耐火时间最短为1.5小时。 A minim
12、um 1.5 hours of fire resistance period against Hydrocarbon Fire shall be applied.Fire Resistance Construction Thickness The thick fireproof coating shall be applied for the Equipment Structure,Equipment Support (such as the skirt ,leg,bracket and saddle), Pipe Rack,Equipment Structure;and it shall b
13、e constructed by trowel as per JB-OPMT-10-005.3)Equipment SupportThe total thickness about 50mm of toweled fire proofing coating shall be applied for equipment support such as the skirt, leg, bracket and saddle.4)Equipment Support Steel Structure and Pipe RackThe total thickness about 50mm of towele
14、d fire proofing coating shall be in accordance with GB 14907-2002. A thickness of 252mm shall be applied for Equipment Support Steel Structure and Pipe Rack.Equipment Surface for insulated Equipment by Hot insulation material The total thickness about 25mm of toweled fire proofing coating shall be a
15、pplied for insulated(by Hot insulation Material)shell body that is requested as fire proofing insulation(up to 7.3m from grade) in BEP3.(see attachment 1) Fireproofing coating around equipment nozzles (including manhole) is not requested in consideration of maintenance point of view.Coating for Fire
16、proofing Coating Surface After fireproof coating construction,its fireproofing coating surface shall be protected with sealing flame retardant polymer coating. Its thickness is over 50um (two layers), the color of top color is RAL 7035(light gray). (二)施工工艺及流程Construction Process and Procedure1)施工工艺C
17、onstruction Process1.1隔热型防火涂料涂装 Insulation Fireproofing CoatingA. 隔热型防火涂料涂装施工准备工作: Preparation:(1) 施工前做好施工人员的安全技术培训,所有参加施工人员应经过培训合格后方能上岗.施工安全按SH3505-1999石油化工施工安全技术规程现场要求执行。Before the commencement, carry out safety and technical training to all workers. Only all involved workers are qualified can the
18、y assume the position. The construction safety on site should comply with SH3505-1999 “Technical Specification for Construction Safety in Petrochemical Engineering”(2) 现场需设有堆料棚,防火涂料进入棚内,并要下垫跳板,上盖篷布,堆放整齐,严禁散包受潮。The shelter should be erected to store materials on site. For the fireproof coating in the
19、 shed, make sure that there is plank underneath and tarpaulin above. Stack the materials in order. Loose packing and moisture is not allowed.(3) 各种施工机械要检修完毕,试运正常。All construction machines should be maintained and the trial run should be normal.B. 隔热型防火涂料涂装施工的环境条件: Environmental Conditions:(1).工作场地:涂
20、装工作应尽可能在室外进行,并应保持环境的清洁、干燥,以防止已涂装好的任何表面被灰尘、水滴、焊接下溅或其它脏污粘附在上面而影响质量。 Working place: Try to carry out the painting work outside. Keep the environment clean and dry to prevent that the painted surface being contaminated by dust, water drop, welding slag or other dirt.(2)环境温度:施工进行时的环境温度一般控制在5-35之间(指涂料施工到涂
21、层干燥固化前的整个过程期间)。风速小于5m/s Ambient temperature: The ambient temperature is usually kept at 5-35 for construction (the whole period from the coating work starting till the drying and solidification of the coating). The wind speed should be less than 5m/s.(4) 相对湿度:涂装施工应控制相对湿度在85%以下。当钢构件表面有结露时不宜作业。Relativ
22、e Humidity: the relative humidity should be controlled below 85% for painting. It is not fit to work if there is dew on member surface.(5) 其它方面:对钢构件需在安装现场进行焊接的部位,应按标准留出规定的长度不涂刷防火涂料,事后进行修补工序。Other factors: For the steel member where needs welding on site, leave the required length not to apply firepr
23、oof coating. Then carry out the touch-up procedure later.C涂覆施工 Coating Construction SG本工程隔热型防火涂料采用喷涂与抹涂施工。In this project, the insulation fireproofing coating uses spraying and brushing.基层防锈处理复检Re-inspect the rust-proof treatment of the base layer作好防污措施及脚手架搭建等准备工作Make preparations such as antifoulin
- 配套讲稿: