1、毕业设计中英文翻译 1 Introduction and scope 1.1 Aims of the Manual This Manual provides guidance on the design of reinforced and prestressed concrete building structures. Structures designed in accordance with this Manual will normally comply with DD ENV 1992-1-1: 19921 (hereinafter referred to as EC2). 1.2
2、Eurocode system The structural Eurocodes were initiated by the European Commission but are now produced by the Comit Europen de Normalisation (CEN) which is the European standards organization, its members being the national standards bodies of the EU and EFTA countries,e.g. BSI. CEN will eventually
3、 publish these design standards as full European Standards EN (Euronorms), but initially they are being issued as Prestandards ENV. Normally an ENV has a life of about 3 years to permit familiarization and trial use of the standard by member states. After formal voting by the member bodies, ENVs are
4、 converted into ENs taking into account the national comments on the ENV document. At present the following Eurocode parts have been published as ENVs but as yet none has been converted to an EN: DD ENV 1991-1-1: Basis of design and actions on structures (EC1) DD ENV 1992-1-1: Design of concrete str
5、uctures (EC2) DD ENV 1993-1-1: Design of steel structures (EC3) DD ENV 1994-1-1: Design of composite steel and concrete structures (EC4) DD ENV 1995-1-1: Design of timber structures (EC5) DD ENV 1996-1-1: Design of masonry structures (EC6) DD ENV 1997-1-1: Geotechnical design (EC7) DD ENV 1998-1-1:
6、Earthquake resistant design of structures (EC8) DD ENV 1999-1-1: Design of aluminium alloy structures (EC9) Each Eurocode is published in a number of parts, usually with General rules and Rules for buildings in Part 1. The various parts of EC2 are: Part 1.1 General rules and rules for buildings; Par
7、t 1.2 Supplementary rules for structural fire design; Part 1.3 Supplementary rules for precast concrete elements and structures; Part 1.4 Supplementary rules for the use of lightweight aggregate concrete; Part 1.5 Supplementary rules for the use of unbonded and external prestressing tendons; Part 1.
8、6 Supplementary rules for plain or lightly reinforced concrete structures; Part 2.0 Reinforced and prestressed concrete bridges; Part 3.0 Concrete foundations; Part 4.0 Liquid retaining and containment structures. All Eurocodes follow a common editorial style. The codes contain Principles andApplica
9、tion rules. Principles are general statements, definitions, requirements and sometimes analytical models. All designs must comply with the Principles, and no alternative is permitted. Application rules are rules commonly adopted in design. They follow the Principles and satisfy their requirements. A
10、lternative rules may be used provided that compliance with the Principles can be demonstrated. Some parameters in Eurocodes are designated by | _ | , commonly referred to as boxed values. The boxed values in the Codes are indicative guidance values. Each member state is required to fix the boxed val
11、ue applicable within its jurisdiction. Such information would be found in the National Application Document (NAD) which is published as part of each ENV. There are also other purposes for NADs. NAD is meant to provide operational information to enable the ENV to be used. For certain aspects of the d
12、esign, the ENV may refer to national standards or to CEN standard in preparation or ISO standards. The NAD is meant to provide appropriate guidance including modifications required to maintain compatibility between the documents. Very occasionally the NAD might rewrite particular clauses of the code
13、 in the interest of safety or economy. This is however rare. 1.3 Scope of the Manual The range of structures and structural elements covered by the Manual is limited to building structures that do not rely on bending in columns for their resistance to horizontal forces and are also non-sway. This wi
14、ll be found to cover the vast majority of all reinforced and prestressed concrete building structures. In using the Manual the following should be noted: ? The Manual has been drafted to comply with ENV 1992-1-1 together with the UK NAD ? Although British Standards have been referenced as loading co
15、des in Sections 3 and 6,to comply with the UK NAD, the Manual can be used in conjunction with other loading codes ? The structures are braced and non-sway ? The concrete is of normal weight ? The structure is predominantly in situ ? Prestressed concrete members have bonded or unbonded internal tendo
16、ns ? The Manual can be used in conjunction with all commonly used materials in construction; however the data given are limited to the following: concrete up to characteristic cylinder strength of 50N/mm2 (cube strength 602 N/mm) high-tensile reinforcement with characteristic strength of 4602 N/mm m
17、ild-steel reinforcement with characteristic strength of 2502 N/mm prestressing tendons with 7-wire low-relaxation (Class 2) strands ? High ductility (Class H) has been assumed for: all ribbed bars and grade 250 bars, and ribbed wire welded fabric in wire sizes of 6mm or over ? Normal ductility (Clas
18、s N) has been assumed for plain or indented wire welded fabric.For structures or elements outside this scope EC2 should be used. 1.4 Contents of the Manual The Manual covers the following design stages: ? gene ral principles that govern the design of the layout of the structure ? initial sizing of m