1、Dell 的服务器 错误代码Cable and Board Presence - Message Code: x1Axx Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur? E1A10 PDBPwrCable High PDB power cable to the planar is missing or bad and s
2、ystem will not power on. Failing device is reseated/replaced/repaired. Yes Pre-Post E1A11 PCIRsrConfig High PCI risers are not configured correctly; some invalid configurations prevent system power on. Failing device is reseated/replaced/repaired. Yes Pre-Post E1A12 PCIRsrMissing High One or all of
3、the PCI risers is missing. This prevents system power on. Failing device is reseated/replaced/repaired. Yes Pre-Post E1A14 SAS Cable A Low SAS cable A is missing or bad. Failing device is reseated/replaced/repaired. Yes Any E1A15 SAS Cable B Low SAS cable B is missing or bad. Failing device is resea
4、ted/replaced/repaired. Yes Any E1A16 SAS Cable FB Low Flex bay SAS cable is missing or bad. Failing device is reseated/replaced/repaired. Yes Any E1A17 PwrCable FB Low Flex bay power cable is missing or bad. Failing device is reseated/replaced/repaired. Yes Any E1A18 PDBCtrl Cable High PDB control c
5、able to the planar is missing or bad and system will not power on. Failing device is reseated/replaced/repaired. Yes Any Temperature - Message Code: x11xx Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When
6、 Event Can Occur? E1114 Temp Ambient Med Ambient temperature has a reached a point outside of the allowed range. Temperature returns to allowable range. Yes Any E1116 Temp Memory High Memory has exceeded allowable temperature and has been disabled to prevent damage to the components. AC Cycle or SEL
7、 clear Yes Any Voltages - Message Code: x12xx Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur? E1210 CMOSBatt Low CMOS battery is missing or the voltage is outside of the allowable Faili
8、ng device is reseated/replaced/repaired. Yes Any 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 1 页,共 8 页 - - - - - - - - - range. E1211 ROMBBatt Low PERC5I RAID battery charger has reported to the Server Management that the battery is either missing, cant charge the
9、 battery (possibly because of high temperatures), or the battery is bad. Failing device is reseated/replaced/repaired. Yes Any W1228 ROMBBatt 24 hours of sustained charge. Yes Any E1214 1.5VPwrGd High 1.5 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any E1215 1.8VPwrGd High 1.8 VV volt
10、age regulator has failed. AC Cycle or SEL clear Yes Any E1216 3.3VPwrGd High 3.3 V voltage regulator has failed. AC Cycle or SEL clear Yes Any E1217 5VPwrGd High 5 V voltage regulator has failed. AC Cycle or SEL clear Yes Any E1218 PCIRsr5VPwrGd High PCI Riser 5 V voltage regulator has failed. AC Cy
11、cle or SEL clear Yes Any E1219 BackplanePwrGd High Backplane voltage regulator has failed. AC Cycle or SEL clear Yes Any E1221 Flex BayPwrGd High Flex Bay voltage regulator power good has failed. AC Cycle or SEL clear Yes Any E1222 VCACHE #PwrGd High VCACHE # voltage regulator has failed. AC Cycle o
12、r SEL clear Yes Any E1223 VRM #PwrGd High VRM # voltage regulator has failed. AC Cycle or SEL clear Yes Any E1225 ESB 1.5VPwrGd High ESB 1.5 VV voltage regulator has failed. AC Cycle or SEL clear Yes Any E1226 PCIRsr1.5VPwrGd High PCI Riser 1.5 VV voltage regulator has failed. AC Cycle or SEL clear
13、Yes Any E1227 LinearPwrGd High Linear voltage regulator(s) has failed. Represents status of multiple voltage regulators used in the video and LOM circuitry. AC Cycle or SEL clear Yes Any E1228 0.9VPwrGd High Memory VTT voltage regulator has failed. AC Cycle or SEL clear Yes Any E1229 CPU # VCORE Hig
14、h Processor # VCORE voltage regulator has failed. AC Cycle or SEL clear Yes Any E122A CPU VTTPwrGd High Processor VTT voltage regulator has failed. AC Cycle or SEL clear Yes Any E122B 0.9 V Over V oltage High 0.9 V regulator voltage has exceeded the allowable voltage range. AC Cycle or SEL clear Yes
15、 Any E122C CPU Power Fault High A voltage regulator failure was detected when the processor regulator(s) was enabled. AC Cycle or SEL clear Yes Any Fans - Message Code: x13xx Message Message Message Message Comments Minimum Action Required to Exists System Phase 名师资料总结 - - -精品资料欢迎下载 - - - - - - - -
16、- - - - - - - - - - 名师精心整理 - - - - - - - 第 2 页,共 8 页 - - - - - - - - - Code String Priority Remove Message from LCD in SEL? When Event Can Occur? E1310 RPM Fan # Low RPM of fan # is outside of the intended operating range. Fan RPM reading returns to a point inside of the intended operating range. Ye
17、s Any E1311 RPM Fan Mod #A Low RPM of fan A in the # module is outside of the intended operating range. Fan RPM reading returns to a point inside of the intended operating range. Yes Any E1311 RPM Fan Mod #B Low Same as above except for fan B of module #. Fan RPM reading returns to a point inside of
18、 the intended operating range. Yes Any E1311 RPM Fan Mod #C Low Same as above except for fan C of module #. Fan RPM reading returns to a point inside of the intended operating range. Yes Any E1311 RPM Fan Mod #D Low Same as above except for fan D of module #. Fan RPM reading returns to a point insid
19、e of the intended operating range. Yes Any E1313 Fan Redundancy Low The system is no longer fan redundant. Another fan failure would put the system at risk of over-heating. Fan redundancy is regained, which requires all fans to be operating within the intended operating range. Yes Any Processors - M
20、essage Code: x14xx Message Code Message String Message Priority Message Comments Minimum Action Required to Remove Message from LCD Exists in SEL? System Phase When Event Can Occur? E1410 CPU # IERR High Processor # has had an internal error (IERR), but this does not always mean that CPU is the prob
21、lem .There are a large variety of issues that cause an IERR. AC Cycle or SEL clear Yes Any E1414 CPU #Thermtrip High Processor # has encountered a Thermtrip(over-temperature) event. AC Cycle or SEL clear Yes Any E1418 CPU # Presence High Processor # is missing/bad and the system is in an unsupported
22、 configuration. AC Cycle or SEL clear Yes Pre-POST E141C CPU Mismatch High Processors are not compatible as defined by Dell .System is in an unsupported configuration. AC Cycle or SEL clear Yes Pre-POST E141F CPU Protocol High BIOS has reported a processor protocol error. AC Cycle or SEL clear Yes P
23、OST, After POST E1420 CPU Bus PERR High BIOS has reported a processor bus PERR (parity error). AC Cycle or SEL clear Yes POST, After POST E1421 CPU Init High BIOS has reported a processor initialization error. AC Cycle or SEL clear Yes POST, After POST E1422 CPU MachineChk High BIOS has reported a m
24、achine check error. AC Cycle or SEL clear Yes POST, After POST System Memory - Message Code: x21xx Message Message String Message Message Comments Minimum Exists System 名师资料总结 - - -精品资料欢迎下载 - - - - - - - - - - - - - - - - - - 名师精心整理 - - - - - - - 第 3 页,共 8 页 - - - - - - - - - Code Priority Action Re
25、quired to Remove Message from LCD in SEL? Phase When Event Can Occur? E2110 MBECrdx DIMM # & # High One of the DIMMs in the set implicated by # & # has had a multi-bit error (MBE).If no memory riser is present the “Crdx ” string is left out of the message. “ x” is the memory riser, A-Z. AC Cycle or