大型燃煤机组深度余热优化利用系统节能分析,张晨旭.docx
《大型燃煤机组深度余热优化利用系统节能分析,张晨旭.docx》由会员分享,可在线阅读,更多相关《大型燃煤机组深度余热优化利用系统节能分析,张晨旭.docx(53页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、 国内图书分类号: TM621.4 国际图书分类号: 621.1 学校代码 : 10079 密级:公幵 硕士学位论文 大型燃煤机组深度余热优化利用系统 节能分析 硕 士 研 究 生 : 张晨旭 导师 :杨勇平教授 申 请 学 位:工学硕士 专 业 领 域:热能工程 培 养 方 式 : 全曰制 所在学院 :能源动力与机械工程学院 答辩日期: 2015 年 3 月 授 予 学 位单位:华北电力大学 Classified Index: TM621.4 U.D.C: 621.1 Thesis for the Master Degree Energy-saving Performance Analysi
2、s of the in-depth Optimized Waste Heat Utilization System for Large-scale Coal-fired Units Candidate: Zhang Chenxu Supervisor: Prof. Yang Yongping School: School of Energy, Power and Mechanical Engineering Date of Defence: March, 2015 Degree-Conferring-Institution: North China Electric Power Univers
3、ity 华北电力大学硕士学位论文原创性声明 本人郑重声明:此处所提交的硕士学位论文大型燃煤机组深度余热优化利用系统节能分 析,是本人在导师指导下 ,在华北电力大学攻读硕士学位期间独立进行研究工作所取得的成果。 据本人所知,论文中除已注明部分外不包含他人己发表或撰写过的研究成果。对本文的研究工 作做出重要贡献的个人和集体,均已在文中以明确方式注明。本声明的法律结果将完全由本人 承担。 作者签名 : 敗 处 曰期: /年 i 月 /扣 大型燃煤机组深度余热优化利用系统节能分析系本人在华北电力大学攻读硕士学位期 间在导师指导下完成的硕士学位论文。本论文的研究成果归华北电力大学所有,本论文的研究 内容
4、不得以其它单位的名义发表。本人完全了解华北电力大学关丁 “ 保存、使用学位论文的规定, 同意学校保留并向国家有关部门或机构送交论文的复印件和电子版本,同意学校将学位论文的 全部或部分内容编入有关数据库进行检索,允许论文被查阅和借阅,学校可以为存在馆际合作 关系的兄弟高校用户提供文献传递服务和交换服务。本人授权华北电力大学,可以采用影印、 缩印或扫描等复制手段保存、可以公布论文的全部或部分内容。 本学位论文属于(请在以上相应方框内打 V) : 保密 ,在 年解密后适用本授权书 不保密 KL/ 作者签名: VLlk 日期: 丨 |年 3 月 |20 华北电力大学硕士学位论文使用授权书 摘 要 随着
5、近年来能源价格的不断攀升以及节能减排政策性要求的日益严格,不 断提高电站效率、降低机组供电煤耗、减少对外排放成为今后我国大力发展火 力发电的重点。 火力发电在长期发展的过程中,节能降耗的措施很多,但利用锅炉尾部烟 气余热加热汽机侧回热系统中的凝结水是一种简便易行且节能收益较好的方 案。本文应用热力学、传热学及流体力学的相关理论,搭建了低温烟气余热回 收节能分析模型。并 从系统安全性及稳定性的角度出发,对常规余热利用系统 应用于实际运行电站时烟气侧及水侧连接方式、换热器管型及管材优选情况进 行了综合对比分析,确定经济性及投资成本均较合理的节能改造方案。然后以 某 1000MW 燃煤机组实际运行数
6、据为例,对常规余热利用系统的节能收益进行 计算,并结合常规余热利用系统的综合换热曲线,分析常规系统在实际降低排 烟温度的过程中存在的节能局限性。 在进一步的工作中,本文立足于常规余热利用系统的节能约束,综合考虑 机炉两侧传热传质过程存在的 能级不匹配 现象。从 温度对口、梯级利用 的角度,提出 一 种将汽机侧回热加热过程、炉侧空气预热过程及余热回收过程 相结合的深度余热优化利用系统。该系统从节能本质出发,创造性的提出将炉 侧与汽机侧的吸热和放热过程充分交叉融合,通过机炉之间烟气、蒸汽、给水 和空气等多工质传热过程间的充分集成,提高了引入汽机侧回热系统中的烟气 能级品位,进而提高机组的热功转换效
7、率。本文从机组的热力性能、节能本质 及技术经济性等方面,对深度余热优化利用系统的合理性进行深入剖析。 本文的研究结果,为实现我国大型燃煤发电机组优化设计和高效运行奠定 了科学理论基础,为机组全工况节 能降耗运行提供了关键技术保障。 关键词 :燃煤电站;综合优化;余热利用;热力学分析;技术经济性 Abstract In recent years, as a consequence of the rapidly increasing energy price and more and more stringent energy-saving and emission reduction polic
8、ies, corresponding measures are taken by the majority of the coal-fired plants in China, including improving the power plant efficiency, reducing the unit standard coal consumption rate as well as C 2 emissions. During the development period of coal-fired power plants, plenty of energy-saving method
9、s are available. Among them, utilizing the flue gas waste heat at the boiler rear area to heat the condensed water in the regenerative system is recognized as a simple but efficient scheme. In this paper, a low-temperature flue gas waste heat recycling analytic model was constructed based on the rel
10、evant theories on equivalent enthalpy drop, heat transfer and fluid flow characteristics. Subsequently, from the perspective of system safety and stability, assuming that the conventional waste heat utilization system is applied to the active power plant, its connecting modes in the flue gas side an
11、d steam-water cycle side, heat transfer tube type and material are analyzed to determine the reasonable retrofitting scheme. Combined with the actual operation data of a 1000 MW coal-fired power unit, the energy-saving benefit of the conventional waste heat utilization system is firstly calculated,
12、and its drawbacks in reducing the exhausted flue gas temperature are analyzed afterwards based on the comprehensive heat exchanging curves. Based on the above completed work and the energy-saving constraints of the conventional waste heat utilization system, with consideration of the “energy grade m
13、ismatch issue which is common during the heat and mass transfer processes in the boiler and turbine side, an in_depth optimized waste heat utilization system is proposed which combines three heating processes comprehensively, including the regenerative heating process in the turbine side, the air pr
14、eheating process in the boiler side and the waste heat utilization process. Essentially speaking, the proposed system creatively combines the heat release and absorption processes in the boiler and turbine side together, by integrating the heat transfer process of various working mediums such as flu
15、e gas, steam, feeding water and the air? energy grade of the flue gas introduced into the turbine side is improved significantly, which can further enhance the heat to work conversion efficiency of the power unit. Moreover, thermodynamic, exergetic and techno-economic analysis are conducted to deepl
16、y explore the energy-saving characteristics of the proposed system. The research result of this paper can lay a firm foundation for the optimization design and efficient operation of the large-scale coal-fired units in China, and it provides key technical support for further reducing the unit energy
17、 consumption rate under various working conditions. Keywords : coal-fired power plant; comprehensive optimization; waste heat utilization; thermodynamic analysis; techno-economic performance 目录 W . I Abstract . II 第 1 章绪论 . 1 1.1 大型燃煤电站锅炉烟气余热利用研究的背景和意义 . 1 1.1.1 锅炉尾部烟气余热回收的意义 . 1 1.1.2 烟气余热利用技术概述 .
18、2 1.2 论文主要研究内容 . 3 第 2 章大型燃煤电站锅炉烟气余热利用节能潜力 . 4 2.1 低温烟气余热资源热力学评价指标 . 4 2.1.1 热平衡分析法 . 4 2.1.2 分析法 . 5 2.1.3 能级及能级平衡分析 . 5 2.2 低温烟气余热资源 . 6 2.2.1 烟气余热资源的定义与评价 . 6 2.2.2 低温烟气的腐蚀特性 .v. 6 2.3 低温烟气余热利用热力学分析模型 . 8 2.3.1 烟气焓计算 . 8 2.3.2 换热量计算 . 9 2.3_3 节能收益分析 . 9 2.4 工质流动特性分析模型 . 10 2.4.1 烟气侧阻力分析 . 10 2.4.
19、2 凝结水侧阻力分析 . 11 2.5 4 . 11 第 3 章常规余热利用系统优化设计及热力性能分析 . 13 3.案例机组概况 . 13 3.2 常规余热利用系统节能优势 . 14 3.3 常规佘热利用系统优化设计 . 15 3.3.1 烟气侧连接方式选取 . 15 3.3.2 水侧连接方式选取 . 17 3_3.3 管型选择 . 19 3.3.4 受热面管材优选 . 20 3.4 常规余热利用系统节能收益分析 . 20 3.5 触 . 22 第 4 章深度余热优化利用系统设计及节能分析 . 24 4.1 深度余热优化利用系统提出 . 24 4.1.1 机炉两侧低温区耦合潜力 . 24 4
- 配套讲稿: