Analysis of the emanometer辐射防护专业英语论文.docx
《Analysis of the emanometer辐射防护专业英语论文.docx》由会员分享,可在线阅读,更多相关《Analysis of the emanometer辐射防护专业英语论文.docx(10页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、Analysis of the emanometerYuan zicheng (Chengdu University of Technology, Chengdu Erxianqiao 610059)Abstract The article Analysis the emanometer in studying field. Used in underground engineering, mining, tourism cave, nuclear facilities, the associated uranium and radon measurement of indoor enviro
2、nment, health supervision and evaluation of radioactive detection, is a search for radon, radon source (th) device management, radiation safety evaluation and other necessary.Keywords emanometer ;Radon ;decay ;admeasuring apparatus1.IntroductionRadon overviewRadon is a natural radioactive decay of r
3、adium isotopes in sub uranium and thorium decay series in the body, itself also has the radiation, emits an alpha particle decay, become the radon progeny, the half-life of 3.825 days.Radon measurement can be used to explore the uranium deposit in recent years has developed to can be used for oil ex
4、ploration, is of great significance in the search for clean energy. Our use of water radon variation of earthquake prediction has been 40 years of history, the recent international and soil atmosphere to predict earthquakes have new breakthrough. In recent years, the World Health Organization announ
5、ced the natural radiation people by 50% is caused by radon and radon in the environment of inhaled too much can cause lung cancer and other diseases, therefore the radon measurement has gradually become a topic of public concern. A comprehensive understanding of instrument types, principle and appli
6、cation for people to pay more attention to. Classification of the radon measurement instrumentMeasuring method and instrument of radon and radon many, there are about 30 more.The physicochemical properties of radonRadon is a colorless odorless transparent unit of inert gas in the standard state, den
7、sity is 9.73kg/m3. When the temperature dropped to -65 into a liquid, its density is 5.7 103kg/mol. The temperature dropped further to -71 become shiny orange solid.Radon is an inert gas, is not easy to produce chemical reaction. Radon decay half-life of 3.825d, when the energy of alpha particles em
8、itted by 5.49MeV. Radon can be dissolved in water and other liquids, it is easy to dissolve in the blood and fat, can be dissolved in the rubber, the lytic factor (the ratio concentration in the air of the liquid sample and) has close relation with temperature, pressure. At the same time radon + ads
9、orption easily activated carbon, clay and other porous materials. Activated carbon adsorption coefficient is a function of temperature, the typical values listed in table -1.Activated carbon adsorption coefficientTemperature-12016405075100200adsorption coefficient15050631022358406302701430Note: the
10、adsorption coefficient is urticant per gram of activated carbon (Bq/m3) ratio.2.Basic knowledge of radon detector1) according to the different situation to classification determinationDivided into the soil radon measurement method of radon in the air, a method for the determination of radon in water
11、, the determination method of three categories, each category also includes a number ofMethods.2) according to the different purposes of measuring radon, took different approachesUse of radon to search for uranium and thorium deposits for earthquake prediction, oil, etc., determination and the envir
12、onment or the indoor radon, the method will be different.3) according to the determination of isotopic species of different classificationDirect measurement of radon itself, or indirectly measuring radon first generation progeny of radium (RaA A; its Po) of radioactive, this also is a kind of classi
13、fication method.4) according to the different sampling methods to classifyCan pump portion of the atmosphere (air, water or soil gas) to determine the grab, or may be passive type (passive) wait for radon spread itself to detector and accumulated for a period of time after the probe to analysis. The
14、 former is called warm method (differential) measurement, and the latter is called the cumulative sum method (integral) measurement.3.List of radon detectorContinuous measuring radon and its progenyIntroductionRadon and its progeny continuous measuring instrument for portable real-time continuous me
15、asurement of radon concentration and radon concentration and total potential multifunctional instrument, as the active sampling structure, has the advantages of typical, can be used in underground engineering, mining, tourism cave, nuclear facilities, places associated uranium series and indoor envi
16、ronmental radon measurement, health supervision and evaluation of radioactive detection, is a search for radon, radon source (th) device management, radiation safety evaluation and other necessary, with the radiation effect on Application Study on estimation of radon and radon dose monitoring requir
17、ements. Available for immediate results, simple operation, easy to carry, suitable for large-scale survey radon level.Conditions of useA) environment temperature: -10 45 Relative humidity: 95% b)C) power supply: 6V battery, equipped with charger, battery charging time can work for 6 hours; can also
18、be used AC220/50Hz.The main technical performanceA): a semiconductor detector, the detector has the advantages of small size, fast response, insensitive to gamma.B) instrument background: 2cpm. Sensitivity: 1.2 10cps/Bq/m (RN).C) detection efficiency of Pu- non-point source: 40% (2 D) counting capac
19、ity of 99999999; measuring range: radon / radon concentration of 2-1 10Bq/m, potential concentration: 1 x 10-10J/m.E) to measure the time interval: 1 (measurement of radon concentration), 3 (sub body and potential measurement) are 26min, namely 26 gives results; 2 for 1 100 minutes according to the
20、radon level set the timing measurement of radon concentration; the inside of the instrument has been set to 26min, can meet the needs of the general measurement of configurable micro printer output data.F) the instrument of high degree of automation, which can change the parameter settings, automati
21、c display, instant results, set up the output function key, it can store 100 historical measurements.G) micro sampling pump: 2L/min (built-in); 30 ordinary filter paper.H) the size and weight: 245*245*255, 3Kg.RLM-I radon detectorIntroductionRadon detector of type RLM-I is radon monitoring method an
22、d technology in the most advanced, Germany based on, and American radon detector is comparable, with high price performance ratio, meet the radon measurement standard measurement requirements for GB14582-1993 and GB30325 and the International Electrotechnical Commission, which can meet the environme
23、ntal monitoring and scientific test uranium radium mine, coal mine, indoor environment, metal mines, health and environmental protection departments RLM-I radon measuring instrument. With soil sampling rod soil radon measurement, matching water gas bubbling device to realize the measurement of radon
24、 in water, supporting the exhalation rate cover and the detection device can realize the measuring radon exhalation rate.Technical parameters:Power source: 220VAC/5VDC, 1A power adapterBattery: 6V/7A batteries battery (when the full power available for instrument work continuously for about 10 hours
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Analysis of the emanometer 辐射防护专业英语论文 辐射 防护 专业 英语论文
限制150内