1、-大型综合楼给水排水消防系统设计_毕业设计说明书-第 55 页大型综合楼给水排水消防系统设计摘 要该建筑为大型综合楼,位于呼和浩特市中心,建筑高度为100.07米,总建筑面积约3.5万平方米。本建筑物所有给水排水均按高层建筑给排水要求进行设计。结合实际情况,根据建筑物的性质,用途,和室内设有完善的给水排水卫生设备,具体的给排水系统设计如下:给水系统:本建筑地下二层至地上六层由室外市政管网直接供水,七至二十四层采用水泵、屋顶水箱和减压阀相接合的给水方式;设两条引入管,从不同的方向引入。既保障了供水安全,又节约了能耗。排水系统:本设计采用污废水分流排放体制。管材采用了具有抗震功能的排水铸铁管,为此
2、可进一步提高环境质量。地下室内消防电梯井旁、泵房地面均设有集水坑和废水提升装置。消防系统:该建筑防火等级属于中危险级级,设计内容包括消火栓系统和自动喷淋系统。在屋顶水箱间内设实验用消火栓装置,消火栓给水管网呈环状布置,各消火栓箱内设消防水泵启动电钮,能直接启动消防泵;室外设地下式水泵结合器,保证消防安全可靠。走廊,办公间,电梯前室设闭式自动喷淋系统,自动扶梯旁的防火卷帘处设置水幕系统。各系统中的立管设在管井内或沿墙敷设,水平管根据各系统的特点明敷或暗敷。关键词:给水;排水;消火栓;自动喷淋。AbstractThis building is the large-scale comprehensi
3、ve building, is located in the centre of Hohhot , the construction is highly 100.07meters, total floor space approximately 35,000 square meters. This building possesses for water draining water presses the high-rise construction to request for draining water to carry on the design. Unifies the actua
4、l situation, according to the building nature, the use, is equipped with the consummation with the room in for the water draining water sanitary equipment, concrete gives the drainage system design to be as follows:Water supply system: This construction underground to ground six by outdoor municipal
5、 administration pipe network direct water supply, the water supply system of seven to twenty-four is the water pump、the roof water tank and the reducing value joins. supposed two lead-in tubes. From different direction introduction. Both has safeguarded the water supply security, and saved the energ
6、y consumption. Drainage system: This design uses the dirt waste water parting emissions system. The tubing used had the shock resistance cast iron pipe waste. might further improve the environment quality for this. In the basement nearby the fire electricity stairwell, the pump house ground are equi
7、pped with the sump and the waste water lifting gear. Fire prevention system: This building fire protection rank belongs to the dangerous levelThe level, the design content including the fire hydrant system and sprays automatically system. In supposes the experimental fire hydrant installment in the
8、roof water tank between, the fire hydrant service pipe net assumes the ring-like arrangement; Room peripheral equation below water pump coupler, guarantee fire prevention safe reliable. The corridor, the work, in front of the elevator the room supposes the closed type to spray the system automatical
9、ly. The system of vertical pipe in pipe or along the wall of pipe laying, level according to the system characteristics that apply or concealed.Key word: for water ;Draining off water ;The fire hydrant ;Spurting voluntarily pours . 目录引 言5设计计算说明书61.给水系统计算61.1.生活用水量计算61.1.1.设计计算依据61.1.2.设计计算61.2.水池、水表
10、的计算71.2.1.水池的计算71.3.给水管网水力计算101.3.1.设计秒流量公式101.3.2.低区生活给水管网水力计算101.3.3.低区给水系统压力校核141.3.4.中区给水管网水力计算151.3.5.高区给水管网水力计算201.3.6.生活水泵的确定252.消火栓系统设计计算262.1.室内消火栓系统的布置262.1.1.室内消火栓管网布置262.1.2.室内消火栓的布置272.2.消防水箱设计计算282.2.1.设计计算依据282.2.2.设计计算282.3.消防水池设计计算292.3.1.设计计算依据292.3.2.设计计算292.4.最不利点消火栓所需压力和实际射流量292
11、.4.1.枪口所需压力312.4.2.水枪喷嘴射流量312.4.3.水带水头损失312.4.4.最不利消火栓口所需压力322.5.消火栓管网水力计算322.5.1.水泵供水工况322.5.2.水箱供水工况332.6.高位水箱设置高度的校核342.7.消防泵的计算与选择352.8.减压阀的计算362.8.1.水箱工况362.8.2.水泵工况362.9.消火栓减压装置的设计与计算373.自动喷水灭火系统计算383.1.高区自喷水力计算(特性系数法)393.1.1.设计计算依据393.1.2.设计计算393.2.地下室自喷水力计算(特性系数法)503.2.1.管网水力计算504.建筑排水系统544.
12、1.生活排水系统544.1.1.系统的选择544.1.2.系统的组成544.1.3.排水管道及设备安装要求544.1.4.系统的设计计算554.2.屋面雨水排水系统664.2.1.系统组成664.2.2.降雨强度664.2.3.屋面雨水汇水面积F的划分原则664.2.4.水力计算66总结67参考文献68谢 辞69引 言毕业设计是实现高等工科院校培养目标所不可或确的教学环节,是教学计划中一个重要组成部分。通过毕业设计训练学生综合应用所学基础课和专业基础课知识。在老师指导下,培养学生独立完成高层建筑给水排水工程的设计能力;让学生熟悉并掌握高层建筑给水排水,消防,热水供应工程的设计内容,方法,步骤;