1、,350 BAR INTERNAL SOLENOIDTANK VALVEREFERENCE MANUALTV-2XX VALVESSpecifically designed for 350 bar Hydrogen, the IMPCO GFI solenoid operated internal tank valve provides enhanced storage system safety. Available in both 12 VDC and 24 VDC models. An integrated temperature and pressure activated relie
2、f device ensures total system safety by ensuring tank protection.Note: Not all models exactly as shown.1CONFIDENTIALITYThe information contained in this document is confidential and proprietary to IMPCO Technologies Control Systems. This information cannot be disclosed to other parties without writt
3、en authorization from IMPCO Technologies. This document is intended only for customers engaged in a current confidentiality agreement with IMPCO Technologies.DISCLAIMERAlthough every effort has been made to provide complete and accurate information, IMPCO Technologies cannot guarantee performance ba
4、sed solely on this document.Table of Contents,PHYSICAL DIMENSIONS2GAS SCHEMATIC AND SPECIFICATIONS4ELECTRICAL SCHEMATIC AND SPECIFICATIONS6TEMERATURE SENSOR7OPTIONAL CONNECTOR AND MATING CONNECTOR8PRESSURE RELIEF DEVICE (PRD)9MANUAL LOCKDOWN9DIAGNOSTICS10SERVIC CHECKS14SPECIAL TOOLS15APPLICATION CON
5、SIDERATIONS162PHYSICAL DIMENSIONSThe internal tank valve is intended to fit into a standard 2-12 UN tank thread, with only 2” 50.8mm protruding beyond the neck of the tank. To keep space requirements to a minimum, all connections are radial to the tank neck. Even the manual lockdown can be accessed
6、from the side.Main materials in gas contact:- 6061-T6 aluminum- Glass-18-8 Stainless steel- 430F and FR Stainless steel- Nitrile- Dupont Vespel- Delrin- Copper wire, insulation- Heatshrink tubingWeight (w/o sensors): 1.925 lbs0.87 kgTank volume displaced:6.4cu. in.0.105 LInlet/Outlet ports:9/16-18 S
7、AE J1926/1, -6 O-ringPRD Port7/16-20 UNFSAE J1926/1, -6 O-ringTank thread:2-12 UN3Minimum clearances inside the tank are given below. These are not a gland or tank design, but only designated minimum clearances.4GAS SCHEMATIC AND SPECIFICATIONSGENERALGas:HydrogenNominal pressure:5075 psi350 BargMax.
8、 overfill pressure.6350 psi438 BargMin. burst pressure:20,300 psi1400 BargOperating temperature:-40C to +85CCv, inlet to tank0.7Cv, inlet to outlet1.2FILLINGThe solenoid does not need to be powered to fill. A pressure differential of about 2 bar (30 psi) opens the solenoid. It then acts as a check v
9、alve, preventing flow back out.The high pressure sensor reads pressure near the inlet, not inside the tank. At high fill rates, it reads higher than the pressure in the tank, due to pressure losses through the valve.The temperature sensor reads the temperature of the gas inside the tank.RUNNINGEnerg
10、ize the solenoid to open the valve.The high pressure sensor reads the tank pressure.Using the manual override tool has the same effect as using the solenoid.WARNING: Use of the manual override tool will damage the solenoid piston seal and the valve must be replaced. Return the damaged valve to IMPCO
11、 Technologies.CLOSEDSimilar condition exists if the manual lockdown is used.Only the PRD is connected to tank pressure. The PRD cannot be isolated from the tank pressure.The temperature sensor still reads gas temperature.The pressure sensor is not connected to the tank and could be removed if the li
12、nes are drained and the manual lockdown is closed.ELECTRICAL SCHEMATIC AND SPECIFICATIONSNominal voltage:12V24VMax. voltage:18V36VCurrent:1 ampTransient clip voltage:40VResistance19.2 +/-5% ohms 20C71.82 +/-5% 20cDielectric Strength of coil 1000VRMS1000VRMSDuty Cycle Continuous Continuous6SOLENOIDTh
13、e solenoid is not polarity sensitive. A transient suppressor is installed to absorb the voltage spike that occurs when the solenoid is released. This keeps the reverse voltage spike down to 40 volts, for about 3 milliseconds. 7THERMISTORThe thermistor is on the pressure side of the valve, inside the
14、 tank. Because of this location the sensor reads the actual gas temperature at that point. However, under high flow conditions, temperature differences of over 30C have been measured between various points in the tank. This is something that must be tested in given tank setups. Sensor Supplier Speci
15、ficationsTYPENTCR25C2.7Kohms +/-2%Tolerance2%Thermal Time Constant10sThermal Dissipation2mW/CPower 25C.25WPower 85C1.25WOPTIONAL CONNECTOR AND MATING CONNECTORIMPCO Technologies can supply the tank valve (including temperature sensor) with either a 16” (40 cm) unterminated pigtail or with a standard
16、 connector on the end of 6” (15 cm) of wire. 9PRESSURE RELIEF DEVICE (PRD)The valve is equipped with a PRD, to vent the tank in the event of a fire. When the valve is exposed to excessive heat, the PRD opens and vents the tank through the vent port. Models are available with either 103C (217F) or 10
17、9C (228F). Model numbers ending in “0”, such as TV-110 are 103C, whereas those ending in “5” are 109C. The 103C (217F) contains cadmium, which is being phased out, while the other does not. IMPCO Technologies suggests that the non-cadmium version be used unless there is a legacy reason to do otherwi
18、se.The PRD is permanently connected to the interior of the valve. Because of this, it cannot be intentionally or unintentionally shut off.The PRD is capable of flowing about 200 grams per second of hydrogen, although actual flow rates will vary. The vent line should be sized to adequately handle thi
19、s flow, and to guide it safely away. The line must also be protected from intrusion of water or other contamination.MANUAL LOCKDOWNThe valve includes a manual lockdown for service work, which shuts off all flow into and out of the tank. The lockdown is a 1/4 hex located on the face of the valve (see
20、 page 2 for diagram). It is normally turned counterclockwise to the fully open position. By turning it clockwise to 5.4 Nm 4ft-lbs, the only flow path into and out of the valve (except the PRD) is closed. Opening the solenoid will have no effect.When any work is done on the valve or related lines, e
21、ngage the manual lockdown. If any leaks are detected in the system, engage the manual lockdown.A separate tool is available to manually force the solenoid to open. This is only to be done when the solenoid has failed and is not capable of opening under power. Once the failure of the solenoid is conf
22、irmed, the lines into and out of the valve need to be emptied. The built-in manual lockdown is removed, and replaced with the manual override tool (see the Special Tools section). This has the same effect as activating the solenoid. This should only be done if the solenoid cannot be opened normally,
23、 as it can damage the valve.The manual override tool should be used in accordance with the “06396-T Manual Override Tool Procedures” (Document # GFIP 258) supplied with the override tool, or available from IMPCO Technologies.WARNING: Use of the manual override tool will damage the solenoid piston se