1、Klass.-Nr./Class.No.69 32 1 November 2005 Electric Wiring in Motor Vehicles Single-Wire,Unshielded VW 603 06 Konzernnorm Descriptors:line,cable,wire,low-voltage cable,single-wire,unshielded,electric wiring Page 1 of 50 Fachverantwortung/Responsibility Normung/Standards(EZTD,1733)EEB/5 Frau Dr.Wiegel
2、 Tel.:+49-5361-9-36678 Just Tel.:+49-5361-9-25934 Sobanski Confidential.All rights reserved.No part of this document may be transmitted or reproduced without prior permission of a Standards Department of the Volkswagen Group.Parties to a contract can only obtain this standard via the B2B supplier pl
3、atform“”.VOLKSWAGEN AG Norm vor Anwendung auf Aktualitt prfen/Check standard for current issue prior to usage.Form FE 41-01.05 Preface The content of this standard in the present issue has been agreed upon between representatives of Audi AG,BMW AG,DaimlerChrysler AG,Porsche AG and Volkswagen AG.The
4、MS Word file is stored in the Volkswagen AG standards department.As it is possible that individual automobile manufacturers modify the specifications,exclusive testing according to supply specification LV 112 is not permitted.Instead,the supplier is obliged to ensure that the currently valid in-hous
5、e standard of the respective automobile manufacturer is available to him.Deviations with respect to the agreed version of LV 112 are represented in italics in the individual in-house standards of the automobile manufacturers.Company-specific as well as informative tests are additionally specified in
6、 the Appendix.The above-mentioned companies agree on mutual recognition of test reports from cable manufacturers as long as the tests are performed by an independent testing institute that is accredited according to DIN EN ISO/IEC 17025.The above-mentioned companies reserve the right to require addi
7、tional tests.The mutual acceptance of the test reports does not automatically result in a release.Changes The following changes have been made as compared to Volkswagen standard VW 603 06:2001-11:Standard completely revised Previous issues 1990-09;2001-11 Contents Page 1 Scope.3 2 General.3 2.1 Basi
8、c supply requirements.4 3 Dimensions and conductor composition.4 4 Drawing entry.4 5 Materials.5 5.1 Conductor,uninsulated.5 5.2 Conductor,tinned.6 5.3 Conductor,other surfaces.6 5.4 Insulation.7 6 Marking and supply specifications.7 6.1 Packaging marking.7 6.2 Manufacturers code.7 6.3 Color coding.
9、7 The English translation is believed to be accurate.In case of discrepancies the German version shall govern.Page 2 VW 603 06:2005-11 6.4 Supply specifications.8 6.4.1 Visual test.8 6.4.2 Testing.8 6.4.3 Packaging units.8 6.4.4 Partial lengths,ties,defects.9 6.4.5 Marking of the delivery unit.9 7 G
10、eneral test conditions.10 7.1 Test matrix.10 7.2 Test climate.12 7.3 Specimens.12 7.4 Rounding of numerical values.12 8 Tests.12 8.1 Cable composition test.13 8.1.1 Insulation test wall thickness Sp(thin-walled cables).13 8.2 Physical and chemical properties of the insulation.13 8.2.1 Density.13 8.2
11、.2 Determination of the extractable portion.13 8.2.3 Determination of viscosity.13 8.2.4 Temperature at 5%weight loss.13 8.2.5 Ignition residue.13 8.2.6 Thermal stability.14 8.2.7 Determining the infrared spectrum.14 8.2.8 Determining the tensile strength and elongation at tear.14 8.2.9 Tear propaga
12、tion strength.14 8.2.10 Determination of cross-linking density.14 8.2.11 Microhardness.14 8.3 Mechanical properties in as-received condition.14 8.3.1 Insulation stripability and secure fit of conductor.14 8.3.2 Insulation abrasion resistance.15 8.3.3 Cable-to-cable abrasion resistance.16 8.3.4 Slidi
13、ng behavior of the cables.17 8.3.5 Bending force of the cables.18 8.3.6 Insulation notch strength.19 8.4 Non-flammability.20 8.5 Electrical properties in as-received condition.20 8.5.1 Specific insulation resistance.20 8.5.2 Measurement of 30-minute voltage protection.20 8.5.3 Measurement of 1-minut
14、e voltage protection(after aging only).20 8.6 Mechanical and electrical properties after mechanical,thermal or chemical stress.20 8.6.1 Stress test.20 8.6.2 Insulation shrinkage under heat.21 8.6.3 Pressure resistance of the insulation under heat.21 8.6.4 Thermal stability in wound state.21 8.6.5 Th
15、ermal overload.22 8.6.6 Short-term aging(240 h).22 8.6.7 Long-term aging(3,000 h).22 8.6.8 Low-temperature winding test(-40 C).22 8.6.9 Low-temperature impact test(-15 C).22 8.6.10 Resistance of cable marking to wiping.22 Page 3 VW 603 06:2005-11 8.6.11 Dynamic flexural strength.23 8.6.12 Kink test.
16、23 8.6.13 Electrical properties during water immersion.24 8.6.14 Humid heat,constant(hydrolysis test).25 8.6.15 Ozone resistance.25 8.7 Mycological test.26 8.8 Compatibility tests.26 8.8.1 Resistance to agents acc.to ISO 6722.26 8.8.2 Resistance to operating fluids and wrapping tapes.27 8.8.3 Resist
17、ance to harness components.30 9 Environmental protection and safety.32 10 Referenced standards.33 A.1 Conductor setup,symmetrical,type A(normative).35 A.2 Conductor composition,asymmetrical,type B(normative).36 A.3 Conductor composition,asymmetrical,type b,used up to March 2005 not for new designs.3
18、7 A.4 Conductor composition,asymmetrical,finely stranded(f),type B with reduced outside diameters.38 A.5 Conductor composition,asymmetrical,extra-finely stranded(ff),type B.39 A.6 Survey of wrapping tapes.40 1 Scope VW 603 06 describes requirements and tests for single-wire,unshielded low-voltage ca
19、bles in a nominal voltage range between 60 V and 600 V.Thin-walled cables with cross sections 6 mm:see Appendices A.1 and A.2 Thick-walled cables with cross sections 6 mm:see Appendices A.4 and A.5 It is recommended to use the basic color orange(RAL 2003)for cables used in nominal voltage range betw
20、een 60 V and 600 V.2 General VW 603 06 only applies to new designs.Cables already used in standard production do not have to be modified.Re-testing can be required if new issues of the standard are released.Subsequent modifications of material,dimensions,manufacturing processes,etc.shall be reported
21、 to the respective design engineering departments;these may demand a new release.The test scope of VW 603 06 and in individual cases special test conditions must be defined in cooperation with and approved by the responsible engineering departments.Cables manufactured according to this standard are
22、subject to technical engineering approval(BMG).Page 4 VW 603 06:2005-11 After technical engineering approval has been granted,the cables are only completely released for use in standard production if the assembler has confirmed proper usability in the form of a first-sample test report(EMPB)during f
23、irst sampling,e.g.Stripping of the insulation Crimpability Ultrasonic weldability Twistability of the contacts,if applicable Crimping of contacts 2.1 Basic supply requirements Standard part drawings take precedence over this standard.Approval of first supply and changes according to Volkswagen stand
24、ard VW 011 55.First samples must be delivered accompanied by a test certificate containing all data regarding the quality requirements listed below.In addition,the test certificate must contain the companys trade name,the manufacturing period of the cables and the companys recipe number for the insu
25、lating material.Deviations regarding the completeness of the data are only permissible in exceptional cases and only with the agreement of the relevant department.Long-term tests are a deciding factor for technical engineering release.Standard production shipments must include the manufacturing date
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 低压 电线 标准
限制150内