积分球校准操作说明精选PPT.ppt
《积分球校准操作说明精选PPT.ppt》由会员分享,可在线阅读,更多相关《积分球校准操作说明精选PPT.ppt(40页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、积分球校准操作说明第1页,此课件共40页哦Photometry光度测量What is photometry?什么是光度测量Photometry is the measurement of light.光度测定是用来测量光If you cannot measure what you produce,you will not be in business for long.如果你不能测量你自己的产品,那么你不会有长久的买卖2第2页,此课件共40页哦Electromagnetic Spectrum电磁波频谱3第3页,此课件共40页哦Radiation辐射Light is the portion of
2、 the Electromagnetic Spectrum that can excite the retina and produce a visual sensation.光是电磁波频谱的一部分,它能刺激视网膜产生视觉Visible Light可见光380 to 800 nmUltraViolet Radiation紫外辐射UV-C -200 to 260 nmUV-B -260 to 320 nmUV-A -320 to 400 nm长波紫外线InfraRed Radiation红外辐射800 to 3600 nm4第4页,此课件共40页哦Relative Eye Sensitiviti
3、es眼睛相对的灵敏度Scotopic Eye Sensitivity Curve暗视觉灵敏度曲线Photopic Eye Sensitivity Curve适光5第5页,此课件共40页哦Integrating Spheres Why use them?积分球In practice,luminous flux is measured using an integrating sphere.习惯上积分球用来测量光通量The spheres are coated with a highly diffuse,reflective and spectrally flat coating.球面上覆盖有一层
4、高反射物质The advantage of a sphere is that the light from the test source is“integrated”via multiple reflections such that the reflected light striking any point on the sphere wall is proportional to the luminous flux emitted by the lamp.球的优势是测试源的光是”完整的”,经过多次反射,反射光照到球面内任何一个点上的灯发出的光通量是均衡的6第6页,此课件共40页哦Sys
5、tem Design系统设计Test Lamp测试灯Baffle挡片Detector探头Baffle挡片AuxiliaryLamp辅助灯Power System第7页,此课件共40页哦Sphere Design球设计Detector to measure the light output.探头测量光的输出Baffle to block the direct light from the lamp from the detector档片阻挡从灯管直接到探头的光We are interested in the integrated reflected light in the sphere not
6、 direct light(Illuminance).我们要测定的是在球内完整的反射光而不是直接照射光Auxiliary Lamp and baffle to monitor the sphere calibrations.辅助灯和挡片是监控球的标准8第8页,此课件共40页哦Sphere Photometer球面光度计9第9页,此课件共40页哦Sphere Theory球原理E=I/r2E=Illuminance照度I=Luminous Intensity发光强度10第10页,此课件共40页哦11E=I/AE=IlluminanceI=Luminous Intensity LINE 1 HAS
7、 ONE REFLECTION直线1有一个反射E1=r/ASphere Theory第11页,此课件共40页哦11222E=I/ALINE 2 HAS TWO REFLECTIONSE2=rr/ASphere Theory第12页,此课件共40页哦112223333E=I/ALINE 3 HAS THREE REFLECTIONSE3=rrr/ASphere Theory第13页,此课件共40页哦ETOTAL=I/r2+r/A+rr/A+rrr/A+.ETOTAL=I/r2+r/A+r2/A+r3/A+.ETOTAL=I/r2+/A S(r+r2+r3+.)ETOTAL=I/r2+r A(1-
8、r)Sphere TheoryETOTAL=r After Baffle Insertion to Block Direct A(1-r)The detector signal is proportional to luminous flux!探测到的信号与光通量成比例第14页,此课件共40页哦Basic Photometry Systems15第15页,此课件共40页哦Units:Lumens 1 lm is 1“light Watt”.单位:Lumens-1lm是1”光瓦”Eye sensitivity corrected power.Definition:The time rate of
9、 flow of radiant energy(radiant power)as weighted by the photopic spectral sensitivity of the eye.定义:光源在单位时间内所发出的光量,其中可产生视觉者If a uniform point light source of 1 cd luminous intensity is positioned at the center of a sphere of 1-m radius,every area of 1 m2 on the inside of the sphere will receive a l
10、uminous flux of 1 lm.如果在一个半径为1m的球内的中心位置有一个光强度为1cd的均匀点光源,在1 m2 内表面接收到的光通量是1lm.Luminous Flux()光通量16第16页,此课件共40页哦Determined by Equation:方程式P()is the spectral power distribution(SPD)of the light source in W/nmP()是光源的光谱能量分布W/nmV()is the photopic spectral sensitivity of the eye used here as a“weighting fa
11、ctor”V()是眼睛产生的视觉-”权重因数”This is the fundamental photometric equation这是光度的基本方程k=683 lm/W Luminous Flux()17第17页,此课件共40页哦P()=lamp power spectra灯能量范围V()=eye sensitivity curve视觉灵敏曲线P()*V()=effective power spectra the eye sees可见功率范围You can think of the eye as a detector with a response curve V()眼睛就象是V()曲线所
12、反应Photometry System Calibration18第18页,此课件共40页哦Photometry System Calibration光度系统标准Why calibrate?为什么用标准?Proper calibration links Philips measurements to Standard International Unitsoptical watt and lumen.飞利蒲测量单位是以国际单位为标准-瓦特和流明US Federal Trade Commission requires that ratings in catalogues,in advertisi
13、ng,etc be based in actual measurements.美国商务委员会要求刊登在目录、广告等要基于实物测量Many customers request certification to ANSI,CSA,or other standards.Photometric measurements are a part of many certifications.许多顾客要求有ANSI,CSA或者其它标准的认证。光度测量也是这些标准中的一部分。Governmental contracts(state and national)many times require certifi
14、cation.政府合同大多数要求有证明Philips Lighting is in the business of providing light and lighting solutions,NOT selling“light bulbs”.We must be able to measure what we sell.飞利蒲照明是供应灯和照明方案,不出售“电灯泡”。我们必须有能力测试我们所卖的。Luminous flux,color,CRI,Lifetime,etc is what we sell and how we differentiate ourselves from others
15、.我们出售的产品的光通量、色温、CRI、寿命等,如何与其它公司区别19第19页,此课件共40页哦Photometry System CalibrationWhy calibrate?Without good measurements,we cannot:没有好的测量法,我们没有好的测量法,我们不能不能:Determine our quality.决定我们的质量Judge the effectiveness of improvements or product cost reductions.判定效力的提升或者生产成本减少Properly analyze customer complaints.
16、完整的分析顾客抱怨Effectively bench mark the competition.有效的竞争基点Provide good data for court cases.提供对案例有益的资料Rebut competition claims and misinformation.反驳竞争要求和误传Support sales.支持销售20第20页,此课件共40页哦Fundamental Calibration Equation标准方程的基本原理Calibrations are typically performed by measuring a known value and then e
17、stablishing a Calibration Factor or Correction Factor as the ratio of the known and Measured Value:标准代表测量一个已知值,设定一个校准因数或者修正因数当作已知和测量值的比率Measured values of unknowns are then calculated as:测量未知值计算如下21第21页,此课件共40页哦Fundamental Calibration Equation方程基本原理The standard lamps are placed in the sphere and ope
18、rated at the electrical characteristics specified by the certificate标准灯放置在球内然后按照说明书进行电特性操作The flux value provided by the certificate is then used to determine the Calibration Factor:根据说明书提供的光通量值测定校准因数For some photometers(LMT I1000 and C1200s)this value can be entered in as the attenuator for the sys
19、tem.这个值可以当作是一些光度计系统的衰减器22第22页,此课件共40页哦Sphere Corrections球体修正Corrections must be applied to integrating sphere measurements to account for Lamp Color,Shape,Size,non-linear(or different)sphere illumination,fixturing,and Intensity Distribution.修正必须适用于累计球(光度计的圆球)测量说明灯的色温、外型、尺寸、非线形(或者不同)球照明、预定时间和亮度分布The
20、corrections are:修正如下:Self Absorption自吸收Spatial空间Intensity Distribution亮度分布Spectral光谱Positional位置23第23页,此课件共40页哦Photometry System Calibration光度测量系统标准There are typically only 2 calibrations required for photometry systems:光度测量系统典型的有2个要求标准Luminous flux(detector based)光通量(基于探头)Spectral光谱Once correction
21、factors are determined,the information can be put into calculation software(such as PDAQ)or spreadsheets and automatically used in the measurement process.一旦确定修正因数,资料应该被输入到计算软件(象PDAQ)或者电子数据表格,自动使用在测量程序中。24第24页,此课件共40页哦Photometry Systems CalibrationCalibration 1:Detector Based Calibration Luminous Fl
22、ux Calibration标准1:探头标准-光通量标准Lumens流明Includes SAF,ID,Spectral,Spatial,Positional Correction Factors包括SAF、ID、光谱、空间、位置、修正因数Equipment:LMT,sphere.设备:LMT、球Calibration 2:Spectral Based Calibration Spectral Power Distribution Calibration标准2:光谱标准-光谱能量分布Spectral Power Distribution光谱能量分布Used to calculate CCT,C
23、RI,x,y,all R-values习惯上计算CCT、CRI、X、Y、所有R值x,y correction factors are dependent upon this calibration,NOT the luminous flux calibration.X、Y的修正因数依赖于这个标准,不是光通量标准。This calibration is currently a“relative”calibration does not include corrections such as SAF,ID,etc.这个标准是当前“相对的”标准-不包括修正象SAF、ID等The calculated
24、 values need only relative values,not absolute values.计算值需要的只是相对值不是绝对值Equipment:DAS,OMA,Monochromator,Spectrometers,etc.设备:数据采集器、OMA、单色仪、分光计等。25第25页,此课件共40页哦Photometry Systems CalibrationCorrection factors applied to luminous flux can include:修正因数适用于光通量包括:Self Absorption Correction:A lamp in a spher
25、e absorbs light emitted by itself and reflected back from the sphere wall,thus reducing the sphere responsivity 自吸收修正:一支灯在球内吸收自身发出和球壁上反射的光,从而减少了球的敏感度Spectral Mismatch Correction:The spectral responsivity of the integrating sphere photometer is not perfectly matched to the eye sensitivity curve V()fu
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 积分 校准 操作 说明 精选 PPT
限制150内