额定电压(6~35)kV交联聚乙烯绝缘电力电缆.doc
《额定电压(6~35)kV交联聚乙烯绝缘电力电缆.doc》由会员分享,可在线阅读,更多相关《额定电压(6~35)kV交联聚乙烯绝缘电力电缆.doc(9页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、额定电压(635)kV交联聚乙烯绝缘电力电缆一、适用范围本产品适用于35kV及以下电力系统中, 可用于输电系统和配电系统,作电力的载体。二、执行标准1、 GB/T 12706.2 额定电压1kV(Um=1.2kV)到35kV(Um=40.5kV)挤包绝缘电力电缆及附件 第2部分:额定电压6kV(Um=7.2kV)到30kV(Um=36kV)2、GB/T 12706.3 额定电压1kV(Um=1.2kV)到35kV(Um=40.5kV)挤包绝缘电力电缆及附件 第3部分:额定电压35kV(Um=40.5kV)电缆三、型号规格电缆的型号型号名 称铜 芯铝 芯YJVYJV22YJV32YJV42YJV
2、62YJV72YJLVYJLV22YJLV32YJLV42YJLV62YJLV72交联聚乙烯绝缘聚氯乙烯护套电力电缆交联聚乙烯绝缘钢带铠装聚氯乙烯护套电力电缆交联聚乙烯绝缘细钢丝铠装聚氯乙烯护套电力电缆交联聚乙烯绝缘粗钢丝铠装聚乙烯护套电力电缆交联聚乙烯绝缘不锈钢带铠装聚氯乙烯护套电力电缆交联聚乙烯绝缘不锈钢丝铠装聚氯乙烯护套电力电缆可按要求生产:阻燃ZR-,无卤低烟阻燃WDZ-,防水FS-,变频电缆BP-等性能产品。电缆规格型 号芯数额 定 电 压 kV3.6/6、6/66/10、8.7/108.7/15、12/2018/20、26/35标 称 截 面mm2YJV YJV62YJV72YJL
3、VYJLV62YJLV721254002540025400254002540025400354003540035400504005040050400YJV22YJV32YJV42YJLV22YJLV32YJLV423254002540025400254002540025400354003540035400504005040050400四、使用条件1、导体长期最高工作温度:902、短路时(最长持续时间不超过5s),电缆导体最高温度不超过250。3、敷设环境温度:聚氯乙烯护套电缆,不宜低于04、电缆允许弯曲半径项目单芯电缆三芯电缆无铠装铠装无铠装铠装安装时电缆最小弯曲半径20D15D15D12D靠
4、近连接盒和终端的电缆最小弯曲半径(但弯曲时要小心控制,如采用成型导板)15D12D12D10D注:D为电缆外径。五、结构示意图35kV以下铜芯、铝芯交线绝缘钢带铠装电力电缆(三芯)35kV及以下铜芯、铝芯交联绝缘电力电缆(单芯)六、性能参数1、20导体直流电阻导体标称截面mm220导体最大直流电阻值/km铜铝25355070951201501852403004000.7270.5240.3870.2680.1930.1530.1240.09910.07540.0601004701.200.8680.6410.4430.3200.2530.2060.1640.1250.1000.07882、电气
5、性能电缆额定电压(U0/U)kV3.6/66/66/108.7/108.7/1512/2018/3026/35例行试验:放电试验电压放电量交流电压试验电压时间kVPCkVmin6.31012.5510.51021515.21030.5520.91042531.21063545.010915型式试验:局部放电试验 电压放电量热循环试验 时间冲击电压试验 电压4h交流电压试验 电压kVPChkVkV6.35186014.410.5518752415.25189534.820.95181254831.25181707245.05182501043、电缆电感(H/m )、对地电容(F/m )和电抗(/
6、m)单芯电缆的电感、电容和电抗标称截面mm23.6/66/6、6/108.7/10、8.7/1512/2018/20、18/3026/35电感H/m电容F/m电感H/m电容F/m电抗/m电感H/m电容F/m电抗/m电感H/m电容F/m电抗/m电感H/m电容F/m电感H/m电容F/m电抗/m25355070951201501852403004000.240.4080.3850.3660.3440.3310.3150.3080.3010.2960.2950.240.260.300.340.380.420.460.500.540.560.610.4330.4110.3980.3790.3540.34
7、40.3340.3220.3130.3020.2990.220.240.270.300.340.370.400.430.480.520.581361291231161111081041009794910.4550.4340.4110.3880.3740.3560.3480.3340.3210.3110.3030.180.190.210.240.270.290.310.340.380.410.4614313612912211811210910510198950.4590.4360.4140.3920.3790.3660.3500.3410.3280.3180.170.180.210.230.25
8、0.270.290.320.340.38142134127121117112108104101970.4180.4550.4360.4170.4040.3920.3760.3600.3470.130.150.160.170.190.200.220.240.260.5280.5030.4270.4120.4000.3820.3660.3520.3400.120.140.150.160.170.180.200.210.23166158134129125120115111107 三芯电缆电感、电容和电抗标称截面mm23.6/66/6、6/108.7/10、8.7/1512/2026/35电感H/m电
9、容F/m电感H/m电容F/m电抗/m电感H/m电容F/m电抗/m电感H/m电容F/m电抗/m电感H/m电容F/m电抗/m25355070951201501852403004000.3630.3510.3310.3140.3010.2890.2800.2730.2660.2630.2590.700.780.91.021.141.261.381.51.621.681.830.3960.3770.3570.3370.3230.3120.3040.2920.2810.2740.2660.220.240.270.300.340.370.400.430.480.520.581251181121061019
10、895928986830.4230.4020.3810.3590.3430.3310.3210.3110.2960.2880.2790.180.190.210.240.270.290.310.340.380.410.46133126120112108104101989391880.4230.4000.3770.3600.3470.3360.3230.3100.3000.2900.170.180.210.230.250.270.290.320.340.381331261181131091061019794910.5280.5030.4270.4120.4000.3820.3660.3520.34
11、00.120.140.150.160.170.180.200.210.231661581341291251201151111074、电缆连接负荷载流量不同环境下载流量校正系数(a)空气中表8环境温度101520253035404550校正系数1.261.221.181.141.091.041.000.940.89(b)土壤中表9环境温度101520253035校正系数1.111.071.041.000.960.92(1)3.6/612/20kVYJV,YJLV,YJV22,YJLV22,YJV32,YJLV32,ZR-YJV,ZR-YJLV,ZR-YJV22,ZR-YJLV22ZR-YJV32