1、真空吸尘器電子元件非正常运行测试修订日期修订单号修订内容摘要页次版次修订审核批准2011/03/30/系统文件新制定2A/0/批准:审核:编制:真空吸尘器電子元件非正常运行测试1.0 Purpose / 目的To evaluate if the sample operated with the electronic components short-circuited or/and open can conform to the relevant safety requirements in UL1017.評估样機電子元件在短路和/或断路非正常运行状况下是否符合UL1017安全標準.2.0 D
2、efinition/概念:None 無3.0 Reference Documents/參考文獻:U.L.1017 CAN/CSA-C22.2 NO.243-01, dated 12-07-2001,Cl 5.10.24.0 Equipment/設備:4.1 Frequency converter. (变频電源).4.2 Stop watch(秒表)4.3 UL finger (UL手指)4.4 3 ampere non-time delay type fuse( 3A快速保險,插頭型)4.5 Withstanding voltage tester. (耐壓測試儀)4.6 White tissu
3、e paper(白紙).4.7 Cheesecloth. (纱布)4.8 Softwood board(软木板)4.9 Digital multimeter(万用表)5.0 General Instructions/說明:5.1 Tests may be conducted at any ambient temperature within a range of 10-40 (50-100). 測試可在1040(50100)之內的環境溫度下進行.5.2 Unless otherwise noted, all tests are to be conducted with appliance co
4、nnected to a 120VAC, 60Hz power source. 除非另外標注,否則所有样機都将连接在120V/60Hz電源下进行測試.5.3 All equipment used must be calibrated on an annual basis. Calibration stickers with last calibration and calibration due date must be affixed to each instrument. 使用的所有設備都必須以一年為周期進行調校.載有最後調校日期和調校周期的調校粘紙必須粘固在每一個儀表上.5.4 A si
5、ngle malfunction (short or open) of any circuit component, such as a resistor, capacitor, solid-state device, and the like, may be applied one at a time. For a discrete, multiple (more than two) terminal devices, such as a transistor, SCR, triac, of an integrated circuit device, any combination of t
6、erminals taken two at a time shall be open- or short- circuited. 短路或断路样機中的电子元件诸如电阻,电容,固态元件等,一次只能测试一个元件;对于诸如晶体管,可控硅,三极管和IC等有多种端子间短路或断路组合的多端子元件,一次只测试两个端子的组合.5.5 Choose the devices whose malfunction may cause most unfavorable results through examination of the sample and its circuit diagram . 分析样機电路,选取
7、功能失效后可能造成火灾,电击或人身伤害危险等的电子元件进行开路或断路测试.5.6 This test may be conducted under draught free condition. The air ejector fan mustnt be turned on until 2 minutes elapse after the test is over. 測試將在无風环境條件下進行,待測試完成2分鐘後才可開啟排氣扇.6.0 Procedure/步驟:6.1 Obtain a representative sample of the appliance to be tested. 準