1、毕业设计(论文)外文资料翻译 系别: 电气工程系 专业: 建筑电气与智能化 班级: 电智061 姓名: * 学号: * 外文出处: LonWorks (用外文写) PCLTA-20 Interface Users Guide 附 件 :1、外文原文; 2、外文资料翻译译文。指导教师评语:签字: 年 月 日1、外文原文(复印件)1PCLTA-20 IntroductionThis guide describes the mechanical characteristics and the hardware and software driver installation for the Eche
2、lon PCLTA-20 Interface (Models 74401, 74402, 74403, 74404, and 74405) and the Echelon PCLTA-20 Protocol Analyzer Card (included with Model 33100-20). Except where noted, the term “PCLTA-20” used in this guide refers to both cards. Echelons PCLTA-20 card is a high-performance LONWORKS interface for d
3、esktop, and embedded personal computers equipped with a 32-bit PCI interface and a compatible operating system. Designed for use in LONWORKS networks that require a PC to monitor, manage, or diagnose the network, the PCLTA-20 card is ideal for industrial control, building automation, and process con
4、trol applications. The PCLTA-20 card features support for a wide range of transceivers, downloadable memory, a network management interface, and Plug n Play capability with Microsoft Windows 95, 98, Me, NT, and 2000 operating systems. The PCLTA-20 protocol analyzer requires Windows 95 or 98. The fou
5、r versions of the PCLTA-20 interface with integral twisted pair transceivers support the TP/FT-10 (Model 74401), TP/XF-78 (Model 74402), TP/XF-1250 (Model 74403), and TP-RS485 (Model 74404) channels, respectively. The Model 74405 PCLTA-20/SMX interface and the PCLTA-20 Protocol Analyzer support SMX
6、transceivers, and may therefore be used on a wide range of channels, including Echelons TP/FT-10 free topology and PL-10, PL-20, and PL-30 power line channels. The PCLTA-20 card can be used as an LNS Fast Network Interface, a standard LNS network interface, or a LonManager API-compatible interface.
7、The LONWORKS PCLTA-20 Protocol Analyzer provides LONWORKS manufacturers, system integrators, and end-users with a rich set of Windows tools and a PCLTA-20 card for observing, analyzing, and diagnosing the behavior of LONWORKS networks. In addition to providing the network analysis functionality, the
8、 PCLTA-20 card included with the protocol analyzer also provides all the functionality of the PCLTA-20 PCI Interface. Introduction The PCLTA-20 card provides any PC equipped with a 32-bit PCI interface and compatible Windows operating system with access to a LONWORKS network. Installation software f
9、or the PCLTA-20 card is included with the Model 33100-20 LONWORKS PCLTA-20 Protocol Analyzer, the Model 37000 LonMaker Integration Tool, the Model 37200 LNS DDE Server, the Model 34309 LNS Application Developers Kit, and the Model 58030-01 Connectivity Starter Kit (which must be purchased separately
10、). The software provides a software-based control panel and a software driver for Microsoft Windows 95, 98, Me, NT, or 2000 operating systems (the PCLTA-20 Protocol Analyzer requires Windows 95 or 98). Installation software also is available on Echelons web site at The control panel provides a conve
11、nient means of setting and modifying installation parameters, as well as displaying error messages. The adapter supports Windows 95, 98, Me, and 2000 Plug n Play operation, simplifying installation and use. The PCLTA-20 card operates at 10MHz and, depending on the model selected, includes either an
12、integral twisted pair transceiver or an SMX transceiver interface. For models with an integral twisted pair transceiver, the network connection is made via a removable screw terminal block. As shown in figure 1.1 below, the LNS network operating system allows any number of installation, maintenance,
13、 monitoring, and control devices to exist in a system and to adapt to network configuration changes automatically. That is, it allows users to reconfigure the system from any user interface device anywhere on the network and ensures that all monitoring and control stations are always up-to-date with
14、 respect to the systems configuration. When used with the appropriate software, the LNS Fast Network Interface functionality of the PCLTA-20 card allows the attached host to tap into the LNS infrastructure as a client or server application.The card also permits the host PC to act as a LONWORKS netwo
15、rk device, running application-specific programs while the card handles lower layer functions such as media access control, collision avoidance, and message validation Firmware for the card is downloaded from the host PC. This allows the card to be updated as new versions of the software and firmwar
16、e are released, without modifying or physically accessing the PCLTA-20 card. This feature extends the useful service life of the card, and minimizes the cost and time associated with software and firmware updates. The card is provided with 32Kbytes of off-chip RAM for use as network and application
17、buffers.Audience This manual is intended for developers and end users of LONWORKS systems using the PCLTA-20 card, and for network integrators and end users of the PCLTA-20 Protocol Analyzer. Content This manual provides detailed technical specifications on the electrical and mechanical interfaces a
18、nd operating environment characteristics for the PCLTA-20 card. Related Documentation The following Echelon publications are suggested for additional information: LONWORKS SMX Transceiver Installation Instructions (078-0145-01) LONWORKS FTT-10A Free Topology Transceiver Users Guide (078-0156-01) LON
19、WORKS Junction Box and Wiring Guidelines Application Note (005-0023-01) LONWORKS TPT Twisted Pair Transceiver Module Users Guide (078-0025-01) LNS for Windows Programmers Guide (078-0177-01) LonManager Protocol Analyzer Users Guide (078-0121-01) LonMaker Users Guide (078-0168-02) LNS DDE Server User
20、s Guide (078-0170-01) PCLTA-20 Configuration PCLTA-20 configuration is accomplished by using the LONWORKS Plug n Play control panel application. Open the control panel application by selecting the LONWORKS Plug n Play icon in the Windows Control Panel. Figure 1.2 PCLTA-20 Control Panel and IconThe L
21、ONWORKS Plug n Play control panel application is divided into three parts: a device selection area, a general settings area, and a control section. The device selection area contains configuration settings and diagnostic controls that are specific to an individual PCLTA-20 card and its device driver
22、. The general settings area contains settings for all PCLTA-20 cards used with the PC. The control section contains buttons for accepting or canceling the changes made in the control panel, as well as a Help button. PCLTA-20 Initialization In most cases, PCLTA-20 initialization occurs automatically
23、upon installation of the card and subsequent power-up of the computer. Manual initialization will be required following software installation to a directory other than c:lonworks, or following the moving of the PCLTA-20 system images. To manually initialize the PCLTA-20 card, verify that the control
24、 panel applications System Image Path entry is correct, then click the Apply button. An error will be reported if an attempt is made to view the transceiver type before the PCLTA-20 card is initialized. Testing the card with the Diagnostics button, assuggested by the error message, produces the diag
25、nosis: “Image file not found.” In this case, return to the control panel applications main window and manually initialize the PCLTA-20 card.Device Specific Settings The PCLTA-20-specific options consist of five separate controls (figure 3.2). These controls are defined as follows:Figure 1.3 PCLTA-20
26、-specific ControlsDevice Selected Controls which PCLTA-20 card is selected for configuration. The PCCLON1 and PCCLON2 drivers are installed by the installation software. If additional drivers have been manually installed, they also will be available. Automatic Flush Cancel For non-LNS images, this f
27、unction controls whether the device driver will automatically force the network interface for the selected PCLTA-20 card to leave the post-reset flush state whenever it is reset; an LNS network interface does not and cannot come up in the flush state. The post-reset flush state prevents any inbound
28、or outbound network traffic following a reset. If this box is not checked, it is up to the client application to manage this state. If it is checked, the device driver will automatically allow network traffic to resume. The default is checked. NI Application Controls the type of image or application
29、 to be used on the PCLTA-20 card. This selection is handled automatically by the protocol analyzer software. For all other applications, a PCLTA-20 card can only hold one image at a time. Loading a new image will replace the currently loaded image. The choices for these images are determined by the
30、image files (.NBI extension) found in the system image path specified under General Settings. Some of the possibilities include the following: PCL10VNI, the LNS Fast Network Interface image (for use with LNS 3 and newer) NSIPCLTA, the LNS network interface image (for use with LNS 1 and LNS 2 only) P
31、CC10L7, the basic network interface application image Transceiver Opens the PCLTA-20 Transceiver dialog (figure 1.4). Choosing this option will retrieve the transceiver configuration of the selected PCLTA-20 card. If there is no PCLTA-20 card currently installed in a PCI-bus slot, a message appears
32、stating that the operating system has removed, or has not loaded, the PCLTA-20 device driver.Figure 1.4 PCLTA-20 Transceiver Dialog BoxThe Transceiver value specifies the transceiver type for the selected PCLTA-20 card. The default transceiver is a TP/FT-10 compatible transceiver. Other standard tra
33、nsceiver configurations, and a custom configuration, may be chosen. The Custom Properties values are not accessible unless the Custom transceiver type is selected: you cannot modify the transceiver type as it is a product of the transceiver ID (XID), however, if the XID is custom then you can modify
34、 the fields using the Custom Properties dialog box. If an incorrect transceiver type error is received while modifying the transceiver type, click the Apply button, then proceed to modify the transceiver type. The Custom Properties area contains custom transceiver properties. The information in this
35、 area reflects the current configuration within the PCLTA-20 card. It will not change until a transceiver is selected, and then configured using the OK or Apply buttons.When configuring a custom transceiver or adding custom parameters for a standard transceiver, the Custom Properties Raw Data values
36、 must be entered as hexadecimal values separated by dashes. Further explanation of Raw Data values can be found in the LonBuilder Users Guide. Diagnostics Opens the PCLTA-20 Diagnostics dialog. For more information, see the section on PCLTA-20 Diagnostics.2、外文资料翻译译文1PCLTA - 20简介本指南描述了埃施朗PCLTA - 20接口
37、(型号74401,74402,74403,74404,和74405)的机械特性及硬件和软件驱动程序的安装和埃施朗PCLTA - 20协议分析器卡(包括型号33100-20)。除特别注明外,在本指南中使用的术语“PCLTA - 20”是指这两种卡片。埃施朗的PCLTA - 20卡是一个用于台式机的采用LONWORKS技术的高性能的接口,并在配备个人电脑的同时嵌入了32位PCI接口和一个兼容的操作系统。该卡为需要用 PC 对LONWORKS控制网络进行监视、管理或诊断的应用而设计的,PCLTA-20卡它非常适合工业控制、楼宇自动化和过程控制应用等。PCLTA-20适配器的特点是集成了双绞线收发器、
38、并带有可下载的存储器和网络管理接口,同时还支持微软Windows 95,98,Me,NT和2000操作系统的即插即用功能。该PCLTA - 20协议分析器需要Windows 95或98。在PCLTA - 20双绞线收发器接口组成的四个版本分别支持TP/FT-10(型号74401),TP/XF-78(型号74402),TP/XF-1250(型号74403),和TP - 485 (型号74404)通道。型号74405 PCLTA-20/SMX接口和PCLTA - 20协议分析器支持SMX为主收发器,因此可在广泛的渠道使用,包括埃施朗的TP/FT-10自由拓扑结构和PL 10、PL - 20和PL
39、- 30电力线渠道。该PCLTA - 20卡可以作为一个LNS快速网络接口,一个标准的LNS网络接口,或者LonManager API的兼容接口。LONWORKS PCLTA - 20协议分析软件为LONWORKS产品制造商,系统集成商和最终用户提供一个简单易用的、基于Windows操作环境的工具和PCLTA - 20卡,使用户可以观察,分析和诊断的LonWorks网络的行为。除了提供网络分析功能,PCLTA - 20卡的协议分析软件还提供了包括所有的PCLTA - 20功能的PCI接口。描述PCLTA-20适配卡是为个人电脑及兼容操作系统提供的高性能的 32 位 PCI 总线LONWORKS
40、 接口卡。安装了PCLTA - 20卡软件是包含在型号33100-20 LONWORKS PCLTA - 20协议分析器,型号37000 LonMaker集成工具,型号37200 LNS的DDE服务器,型号34309 LNS的应用程序开发工具包,型号58030 - 01连接入门套件(必须单独购买)。软件为微软Windows 95,98,Me和2000操作系统提供一张基于软件的控制面板和一个软件驱动器(PCLTA-20协议分析软件要求Windows 95或98)。安装软件也可以在埃施朗公司在网站 95,98,Me和2000的即插即用操作,简化了安装和使用。该PCLTA - 20卡工作在10MHz
41、时,根据选定的模式,包括任何一个完整的双绞线收发器或SMX收发器接口。对于一个完整的双绞线收发器模式,网络连接则通过一个可拆卸的螺钉接线端子。如图1.1所示,LNS网络操作系统允许任何数量的安装,维护,监控和控制装置存在于一个系统,以适应网络配置自动改变。也就是说,它允许用户从网络上的任何接口位置重新配置系统,并确保所有的监测和控制站总是随着系统的配置不断更新。当配以适当的软件,这套LNS的快速网络接口的PCLTA - 20卡具有允许连接主机作为客户端或服务器应用程序。控制设备 (传感器, 执行机构, 电动机, 等等.)服务技术工具远程监控工具操作员控制台网关控制面板监管维护工具远程控制台外围
42、系统图1.1 基于LNS的多系统工具该卡还允许主机充当LONWORKS的网络设备,运行具体方案的应用程序,同时该卡处理较低层的功能,如媒体访问控制,避免冲突,和信息验证。卡片的固件可以从主机上下载。这使得卡的软件和固件版本的更新更加轻松,而不需要拆卸或是更换PCLTA - 20卡。这个特性延长了适配器的有效使用时间,并降低有关软件和固件升级时所需要的时间和费用。该卡提供32KB的内存芯片缓冲区用于网络和应用程序缓冲存储器。观众本手册适用于开发人员及使用PCLTA-20卡的LonWorks系统终端端用户和网络集成商及PCLTA - 20协议分析器的终端用户。内容本手册提供电气和机械接口的详细的技
43、术规格资料以及PCLTA - 20卡和操作环境特征。相关文档以下埃施朗出版物提示的附加信息:LONWORKS技术SMX收发器安装说明(078 -0145-01)LONWORKS技术FTT-10A型自由拓扑收发器用户指南(078-0156-01)LONWORKS技术的接线盒与接线准则应用指南(005-0023-01)LONWORKS技术TPT双绞线收发模块用户指南(078 - 0025-01)LNS的Windows程序员指南(078-0177-01)LonManager协议分析软件用户指南(078-0121-01)LonMaker用户指南(078-0168-02)LNS的DDE服务器用户指南(0
44、78 - 0170-01)PCLTA - 20配置PCLTA - 20是通过使用播放的LONWORKS技术随插即用控制面板应用程序。打开播放控制面板应用程序的控制LONWORKS技术即插即用图标在面板应用程序通过选择Windows控制面板。图1.2 PCLTA - 20控制面板和图标LONWORKS技术的即插即用播放标识的LONWORKS技术的即插即用是分为三个部分:一种设备选择区,面积一般设置,控制部分。该器件选择区域包含配置设置和所特有的个人PCLTA - 20卡及其设备驱动程序的诊断控制。该区的整体设置包含所有PCLTA - 20使用的PC卡的设置。控制部分包括案件受理或按钮控制面板取消
45、所做的更改,以及一个帮助按钮。PCLTA - 20初始化在大多数情况下,PCLTA - 20卡的初始化发生后,将自动安装在计算机。手动初始化将需要下列软件安装到一个不是c: LonWorks的目录,或跟随移动的图像的PCLTA - 20系统。 手动初始化PCLTA - 20卡,要验证该控制面板应用程序的系统的图像路径项是正确的,然后点击应用按钮。 如果在PCLTA- 20卡初始化前试图看收发器类型,将报告一个错误。如表明是错误信息,测试与诊断按钮会生产诊断:“图像文件没有找到。”在这种情况下,返回到控制面板应用程序的主窗口和手动初始化PCLTA - 20卡。设备设置的具体PCLTA - 20
46、-具体方案包括5个(图1.3)单独控制。这些控件定义如下:图1.3 PCLTA - 20 -特定控件设备选择其中PCLTA - 20卡是配置选择控制。该PCCLON1和PCCLON2的驱动程序是安装软件安装的。如果其他驱动程序已被手动安装,它们也将可用。 自动刷新取消 对于非LNS的象,这个功能控制着设备驱动程序是否会自动生效的网络接口卡为选定的PCLTA- 20卡,离开后重置刷新状态时它被重置; 1个 LNS网络接口不能在刷新状态工作。后重置刷新状态阻止任何复位后的网络通信的入站或出站。如果此框未选中,也应该由客户端应用程序来管理这个状态。如果它被选中,该设备驱动程序将自动允许网络流量恢复。
47、默认为选中。 NI应用 图像的类型控制或应用程序,用于PCLTA - 20卡。这一选择是自动协议分析软件处理的。对于所有其他应用程序,PCLTA - 20卡一次只能持有一张图片。载入一个新的图像,将取代当前加载的图像。对这些图像的选择是取决于图像文件(NBI的扩展)发现于在通常设置的系统映像的路径。对一些可能性包括以下内容: PCL10VNI, LNS的快速图像更新的网络接口(以及LNS 3和新的使用) NSIPCLTA, LNS网络接口的图像(只使用LNS1的一和LNS2) PCC10L7, 基本的网络应用程序接口形象收发器 打开PCLTA - 20收发器对话框(图1.4)。选择此选项将检索所选PCLTA - 20卡的收发器配置。如果没有PCLTA - 20卡插槽,目前安装在一个PCI总线,将出现一条消息,说明该操作系统已去除,或没有加载,PCLTA - 20设备驱动程序。图1.4 PCLTA - 20收发器对话框该收发器值指定选定PCLTA -20卡的卡收发器类型。默认收发