椰树街配套农贸市场项目—节能计算书.docx
《椰树街配套农贸市场项目—节能计算书.docx》由会员分享,可在线阅读,更多相关《椰树街配套农贸市场项目—节能计算书.docx(64页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、建筑节能设计报告书公共建筑甲类工程名称驸马片区椰树街配套农贸市场工程工程地点设计编号GS (20) 10-01建设单位设计单位设计人校对人审核人设计日期埃匡m重尔数X数SCp系数uW/(m.K)W/(m2.K)kg/m3J/(kg.K)g/(m.h.kPa )水泥砂浆0.93011.3701800.01050.00.0210来源:民用建 筑热工设计规 范GB50176-2016石灰砂浆0.81010.0701600.01050.00.0443来源:民用建 筑热工设计规 范GB50176-2016钢筋混凝土1.74017.2002500.0920.00.0158来源:民用建 筑热工设计规 范GB
2、50176-2016挤塑聚苯乙烯泡沫塑 料(带表皮)0.0300.34035.01380.00.0000来源:民用建 筑热工设计规 范GB50176-2016, 蒸汽渗透系数没 有给出混凝土多孔砖(190六 孔砖)0.7507.4901450.0709.40.0000自然煤砰石、炉渣混 凝土 (p= 1300)0.5607.6301300.01050.00.1050SBS改性沥青防水卷 材0.2309.370900.06643.00.0000C20细石混凝土 (p=2300)1.51015.2432300.0920.00.0000多孔砖砌体0.5807.9201400.01050.00.015
3、8岩棉板(p=60160)0.0410.615110.01220.00.4880抗裂砂浆增强防护层0.93011.3061800.01050.00.00004.2围护结构作法简要说明1 .屋顶构造:屋顶构造一:(由上到下)C20细石混凝土(p=2300)40mm+水泥砂浆20mm+挤塑聚苯乙烯泡沫塑料(带表皮)65mm+ 水泥砂浆20mm+ SBS改性沥青防水卷材3mm +水泥砂浆20mm+自然煤肝石、炉渣混凝土 (p=1300) 30mm + 钢筋混凝土 120mm2 .外墙:外墙构造一:(由外到内)抗裂砂浆增强防护层5mm+岩棉板(p=60160) 45mm+多孔石专砌体200mm3 .热
4、桥柱: 热桥柱构造一:(由外到内)抗裂砂浆增强防护层5mm+岩棉板(p=60160) 45mm+钢筋混凝土 200mm4 .热桥梁:热桥梁构造一:(由外到内)抗裂砂浆增强防护层5mm+岩棉板(p=60160) 45mm +钢筋混凝土 200mm5 .热桥板: 热桥板构造一:(由外到内)抗裂砂浆增强防护层5mm+岩棉板(p=60160) 45mm+钢筋混凝土 200mm6 .挑空楼板构造:挑空楼板构造一:(由上到下)钢筋混凝土 100mm+水泥砂浆20mm+岩棉板(p=60160) 40mm7 .幕墙: 多腔隔热金属窗框6中透光三银Low-E+12A+6透明:传热系数L600W/m八2.K,太阳
5、得热系数0.2088 .外窗:多腔隔热金属窗框6中透光三银Low-E+12A+6透明:传热系数L600W/m八2.K,太阳得热系数0.2084.3体形系数外外表积6416.48建筑体积32369.28体形系数0.204.4窗墙比4. 4. 1 窗墙比朝向立面窗面积(面)墙面积(而)窗墙比限值结论北向北-默认立面1772.151905.530.930.70不适宜东向东-默认立 面975.171049.500.930.70不适宜西向西-默认立 面1300.911395.290.930.70不适宜标准依据四川省公共建筑节能设计标准DBJ51/143-2020第条标准要求夏热冬冷地区甲类公共建筑各单一
6、立面窗墙面积比(包括透光幕墙)均不埃匡m重尔宜大于0.70结论不适宜4. 4. 2 外窗表朝向立面编号尺寸楼层1=1 数里单个面积 (m2)合计面积 (m2)北向北-默认立面1772.151162.2562.25164.9529.701117.6717.671121.7621.761120.4520.451138.3338.331117.0917.0912215.1130.211111.2111.21115.555.551112.9012.90117.597.59111.141.141118.9018.901192.8892.881222.164.321114.8614.861118.8918
7、.89218.268.262244.0188.022192.0692.062124.8524.852126.4626.4621125.28125.282149.9549.9534316.8050.4034216.8033.603125.5325.53310.730.733111.1911.193118.4118.413167.2067.203429.6019.2034235.6071.203216.8033.60埃匡m重尔34418.0072.0034221.2042.403531.604.804125.1825.1845210.4020.8045211.1922.3845218.4136.8
8、24123.2023.204133.6033.60412.402.404112.8012.804110.8010.804110.8010.804113.8013.804135.8035.804136.0036.005121.6021.605112.4012.40512.052.05522.855.70513.153.155192.1592.15514.254.255125.6025.60透光门-M15211,583.1525.20透光门-M2321114.834.83东向东-默认立 面975.17112.292.29124.959.901142.4842.48111.121.12117.597
9、.591130.7430.74114.204.201123.5023.50114.854.85112.972.97113.243.241129.4029.401129.1729.172140.1740.172122.3022.30埃匡m重尔2221.0642.122144.2844.282135.7935.792133.1633.16215.735.733113.2013.203422.785.573462.8517.103421.623.233134.4034.40311.131.1334250.35100.69312.402.403115.6015.603122.4022.4035431.
10、20124.80315.445.443420.541.083122.7922.79312.412.413110.7810.78314.424.4235321.2063.604117.2017.204122.4022.404117.2017.201.48x4.00415.935.935110.4010.405110.4010.40透光门-M0921111.891.89透光门-M15211,3-463.1518.90透光门-M2321114.834.83西向西-默认立 面 1300.911121.5021.501124.9424.941178.8478.84114.854.85144.9519.8
11、0114.334.3312214.0428.08114.564.561121.0921.09埃匡m重尔118.248.24118.228.22111.441.44116.606.601113.1513.151112.0612.06110.900.901117.2817.281131.3231.322123.7623.762110.8010.802131.2031.202118.9018.902114.1514.152121.0621.062126.4826.482117.2817.282115.1215.122118.6318.632125.6525.652124.3024.302148.60
12、48.60319.609.60310.730.733117.6017.60318.008.003113.5913.593121.6121.613,5213.8027.603119.0019.003116.8016.803116.8016.803120.1920.19332.858.55318.218.213121.1021.103116.5616.563,5236.0072.0034265.60131.2034331.2093.603111.9511.95埃匡m重尔3113.2513.254143.6543.65512.402.405112.8012.805110.8010.805110.80
13、10.805118.2018.205134.4034.40透光门-M1521143.1512.60透光门-M2021114.204.204.5可见光透射比朝向立面窗墙比最不利窗编号最不利透射比透射比限值北向北-默认立 面0.930.620.40东向东-默认立 面0.930.620.40西向西-默认立 面0.930.620.40标准依据四川省公共建筑节能设计标准DBJ51/143-2020第条标准要求当窗墙面积比小于0.40时,玻璃的可见光透射比不应当小于0.6;当窗墙面积 比大于等于0.40时,玻璃的可见光透射比不应当小于0.4;结论满足4.6天窗4. 6.1 天窗屋顶比本工程无此项内容4.
14、6.2天窗类型 本工程无此项内容4. 7屋顶构造4. 7.1屋顶构造材料名称 (由上到下)厚度b导热系数 X蓄热系数S修正系 数热阻R热惰性指 标(mm)W/(m.K)W/(m2.K)a(m2 K)/WD二R*SC20细石混凝土(p=2300)401.51015.2431.000.0260.404水泥砂浆200.93011.3701.000.0220.245挤塑聚苯乙烯泡沫塑料(带表皮)650.0300.3401.201.8060.737水泥砂浆200.93011.3701.000.0220.245埃匡m重尔SBS改性沥青防水卷材30.2309.3701.000.0130.122水泥砂浆200
15、.93011.3701.000.0220.245自然煤肝石、炉渣混凝土(p=1300)300.5607.6301.000.0540.409钢筋混凝土1201.74017.2001.000.0691.186各层之和Z3182.0323.591外外表太阳辐射吸收系数0.75传热系数 K=l/(0.16+ZR)0.46标准依据四川省公共建筑节能设计标准DBJ51/143-2020第331条标准要求K应满足表的规定(KS0.50)结论满足4. 8外墙构造4. 8.1外墙相关构造外墙构造材料名称 (由外到内)厚度3导热系数 X蓄热系数S修正系 数热阻R热惰性指 标(mm)W/(m.K)W/(m2.K)a
16、(m2 K)AVD=R*S抗裂砂浆增强防护层50.93011.3061.000.0050.061岩棉板(p=60160)450.0410.6151.200.9150.675多孔砖砌体2000.5807.9201.000.3452.731各层之和Z2501.2653.467外外表太阳辐射吸收系数0.75传热系数K=l/(0.16+ZR)0.704.8.1.2 热桥柱构造材料名称 (由外到内)厚度b导热系数 X蓄热系数S修正系 数热阻R热惰性指 标(mm)W/(m.K)W/(m2.K)a(m2 K)/WD=R*S抗裂砂浆增强防护层50.93011.3061.000.0050.061岩棉板(p=60