MTL8000电源模块说明书.pdf





《MTL8000电源模块说明书.pdf》由会员分享,可在线阅读,更多相关《MTL8000电源模块说明书.pdf(7页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、GeneralGood power supply managementis at the heart of the MTL8000system.AC and DC power supply units areavailable to suit the availableresources.All units are designed to endurethe harsh environmentalconditions that are frequentlyfound in process plants and,naturally,they meet rigorous EMCand electr
2、ical safety standards.Power supply connections areminimised and simplified toensure that power provisionrequires the minimum of wiringeffort 8000 series power supplies aredesigned to support redundancywhen required.Most have“health”signal outputs for earlywarning of problems.EUROPE(EMEA)Tel:+44(0)15
3、82 723633 Fax:+44(0)1582 422283AMERICASTel:+1 603 926 0090Fax:+1 603 926 1899ASIA PACIFICTel:+65 487 7887Fax:+65 487 7997E-mail:enquirymtl- Web site:www.mtl-June 2004Power suppliesDC system power supplyThe 8910-PS-DC DC input power supplyprovides a regulated 12 V 4.9 A outputfrom a DC input voltage
4、range of 18.5 up to36V.This input voltage range accommodates the typical 24 V DC suppliesavailable on process plants worldwide.This power supply is designed to mountdirectly on 8711-CA-NS or 8712-CA-NSnode services carriers or on a 8717-CA-PSpower supply carrier.On the node servicescarriers mentione
5、d here,two positions areprovided.This enables a second powersupply to be mounted,under conditionswhere the user wants to provide additionalpower,or where a redundant power supplyis required to provide maximum systemavailability.DC IS module supplyPower Supply module 8920-PS-DC mountson its own carri
6、er(8724-CA-PS)and acceptsa locally available 24V dc(nominal)supply and converts it to 12V dcfor powering MTL8000 I/O modules thathave intrinsically safe field wiring.Its 5A output is capable of poweringbetween six and twenty I/O modules,depending on the module types and theirmix.A number of 8920-PS-
7、DC modules may beused together,within an MTL8000 node,ina load-sharing arrangement.Where powersupply redundancy is required an additional supply module may be added inan“n+1”arrangement.Failure of anypower supply is signalled to the Bus InterfaceModule.AC power suppliesThe 8913-PS-AC and 8914-PS-AC
8、suppliesproduce DC output power from a widerange of AC inputs.Both can be mounted ina Zone 2 or Division2 hazardous areawhich means that they can be used for abroad range of applications includingsupplying power to 8000 series modules.System powerThe 8913-PS-AC is a dual output supplycapable of prod
9、ucing 12 V and 24 V DCoutputs of approximately 5 A.For 8000 series products,the 12 V outputcan be used to supply system power to thenode and also provide 24 V to power fielddevices via the field power bussing facilitieson the 8000 series carriers.Field powerThe 8914-PS-AC has a single 24 V DCoutput
10、with a 10 A capacity.This is ideal forpowering a wide range of field devices.With 8000 series products,it is normallydistributed via the field power bus(seebelow).Load sharingA load sharing diode is built in to the 12Voutput of the 8913-PS-AC power supply andthe 24V output of the 8914-PS-AC.Thisenab
11、les one or more of the same powersupply type to be connected in parallel toshare the load requirements.Power health signallingThe 8913-PS-AC and the 8914-PS-ACsupplies provide power health signals thatcan be routed to the BIM to warn of possibleimminent power failure.The 8913 provides the power heal
12、th signalfrom its 12 V DC output.Bussed field power (2/2 modules/carriers only)In addition to the system power supply,anMTL8000 node may need to be suppliedwith additional field power.Conventional systems require field powersupplies to be wired in at the field terminalsor via additional patching con
13、nectors.Thisadds complication to the field wiring andcan be a source of confusion during maintenance work.The MTL8000 system overcomes this complication with a system for bussingpower on the carriers.Each carrier can busan external power supply to modules so thatthey can energise the field wiring.In
14、 the case of the 4-20mA Analog Input andOutput modules,the bussed field power isalso used to energise the field interface circuits.The connection for the bussed field power islocated at the top of the carrier and uses atwo-part removable connector.Individualbussed field power supplies connect to two
15、modules.If an adjacent pair of modulesrequire the same power supply voltage theconnector can be wire-linked to provide it,otherwise a different supply voltage(AC orDC)can be connected.EUROPE(EMEA)Tel:+44(0)1582 723633 Fax:+44(0)1582 422283AMERICASTel:+1 603 926 0090Fax:+1 603 926 1899ASIA PACIFICTel
16、:+65 487 7887Fax:+65 487 7997E-mail:enquirymtl- Web site:www.mtl-June 2004Power suppliespower for 2/2(general purpose)node12 V DC output18.5-36V DC input4.9 A capacity supports redundancy with second supplyMODULE SPECIFICATIONHAZARDOUS AREA APPROVALSLocation of node.Safe area or.Class 1,Div 2,Groups
17、 A,B,C,D T4 hazardous location or.Zone 2,IIC T4 hazardous areaApplicable standards:Factory Mutual Research Co.,Class No.3611 for Class I,Division 2,Groups A,B,C,D hazardous locationsELECTRICALEMC compliance.To EN 50081-2 and EN 50082-2.generic emission/immunity standardsElectrical safety.EN 61010-1:
18、1993 and Amendment A2:1995OUTPUTOutput voltage.12 V dc 5%Output current.4.9 AInput-output isolation.50 V ac rms,720 V dc.(Continuous working to EN 61010-1,Pollution Degree 2,.Installation Category 2)Hold-up(on i/p supply failure).7 ms.(40C,full load and 22V input)Thermal protection.Protected against
19、 output s/cSupply health indicator.LED(fed from final output)Power-fail signal to BIM(o/p threshold).8.5 2 VINPUTInput voltage.18.536 V dcEfficiency(at full load)20 V input at 3.6 A.82.5%24 V input at 3.1 A.80.0%36 V input at 2.1 A.80.0%Input connection.Two-part,screw terminal.each connection duplic
20、ated,2.5 mm2 max.cable cross-sectionInput protection.Fuse+supply reversal diodePower-fail signal to BIM(i/p threshold).19.9 0.5 VENVIRONMENTALOperating temperature(no forced ventilation)(60%of full load).40C to+70COptimum orientation(full load).40C to+55CWorst case orientation(full load).40C to+50CS
21、torage.40C to+85CRelative Humidity.5 to 95%RH(non-condensing)Vibration.2 g 10-100 Hz to BS EN 60068-2-6.and BS 2011-part 2.1Shock.10 g,11 ms pulse width,to BS EN 60068-2-27MTBF 50C external ambient.80,000 hrsIngress Protection.IP20 to IEC 529/BS EN 60529(tested on power supply carrier with all suppl
22、y connectors in place)Corrosive atmospheresTo withstand gaseous corrosion level G3 as defined by ISA StandardSP71.04:1995,when protected by a suitable field enclosure.MECHANICALDimensions(approx.).42(w)x 110(h)x 160(d)mmCarrier mounting.types 8711-CA-NS or 8712-CA-NSWeight.775 gSystem power supply89
23、10-PS-DCEUROPE(EMEA)Tel:+44(0)1582 723633 Fax:+44(0)1582 422283AMERICASTel:+1 603 926 0090Fax:+1 603 926 1899ASIA PACIFICTel:+65 487 7887Fax:+65 487 7997E-mail:enquirymtl- Web site:www.mtl-June 2004power for 2/1(IS)modules12 V DC output24 V DC(nominal)input5 A capacitysupports load sharing for redun
24、dancyMODULE SPECIFICATIONHAZARDOUS AREA APPROVALSLocation of power supply.Safe area or.Class 1,Div 2,Group A,B,C,D hazardous location.Zone 2,IIC T4 hazardous areaOutput.Galvanically isolated.Voltage clamped;Un=18 VApplicable standards:Factory Mutual Research Co.,Class No.3611 for Class I,Division 2,
25、Groups A,B,C,D hazardous locationsFactory Mutual Research Co.,Class No.3610 for Class I,II,III,Division 1,Groups A-G hazardous locations(IS circuits)EN 50020:1994 Electrical apparatus for potentially explosive atmospheres,intrinsic safety“i”EC Directive 94/9/EC (ATEX)ELECTRICALEMC compliance.To EN 5