1、阴保程序文件1. PURPOSE. 22. SCOPE. 23. DEFINITIONS. 24. RESPONSIBILITIES 25. DEVELOPMENT 26. DOCUMENTS 27. HEALTH, SAFETY AND ENVIRONMENT1. PURPOSE.The purpose of this procedure is to establish Ldta YPFB activities, for installation of cathodic protection at the bottom of storage tanks and pipes buried or
2、 submerged.2. SCOPE.This procedure applies to installing the cathodic protection storage tanks and pipes buried or submerged by the methods of sacrificial anodes and impressed current.3. DEFINITIONS.- 8535-EZ-014-C_SIGNED MEMORIA ESTUDIO DE SISTEMA DE PROTECCIN CATDICA- NACE TM 0497 Measurementes to
3、 related techniques to Criteria for Cathodic Protection on Underground or Submerged Metallic Piping System- NACE TM 0101 Measurementes to related techniques to Criteria for Cathodic Protection on Underground or Submerged Metallic Tank Systems- API RP 1632 Cathodic Protection for Underground petroleu
4、m storage Tank and Piping Systems- Sacrificial anode: generally specific Metal Magnesium, Aluminum, and Zinc, for the protection of storage tanks and buried or submerged pipelines, metals forming a galvanic couple with iron (Mg-Fe) which will protect from corrosion .- Anode Cathodic Protection Impre
5、ssed Current: generally specific Metal Fe-Si, graphite, titanium, and other metals used MMO to drain current to the electrolyte in order to protect from corrosion buried or submerged structure.- Reference electrode: A half cell is usually copper or silver copper sulphate silver chloride, calomel, zi
6、nc, etc. Used to measure the cathodic protection potential-floor structure.- Electric Potential: Measure voltage between two points, a reference point or zero point and the point to be measured, interface of positive and negative charges.- Thermal welding using metal powder: exothermic welding type
7、consists of metallic powders ignition properties to perform a desired electrical connection between wire to wire or wire-blade4. RESPONSIBILITIES4.1. Manager workProvide the necessary resources to implement the provisions of this procedure.4.2. Electrical and instrumentation Super IntendantDirect an
8、d monitor the activities.Implement activities under Policies and Procedures.Review and comply with the provisions of this procedure.Evaluate and verify specific welding procedures.Approve and monitor the activities related to these proceedings.Will be responsible for the inspection, verification, mo
9、nitor and record the activities related to the activity.4.3. Quality Inspector.Monitor compliance with the provisions of this procedure.Control inspections and checks required by this procedure.To Implement the Quality Plan and Inspection and Test Plan4.4. Cathodic Protection Inspector.The subcontra
10、ctor will designate a person trained and qualified, which is the one that you track all activities relating to cathodic protection.5. DEVELOPMENT5.1. Technical criteriaThe cathodic protection system must be both impressed current and galvanic current as independent of the existing cathodic protectio
11、n systems both underground pipes as the inside of the tanks or storage tanks.Cathodic protection systems to be installed metal structures protect the following:- Internal surface of tank storage- Corresponding outer buried surface to the bottom of storage tanks- External surface for buried piping be
12、 cathodically protected are those for general planimetry underground networks, storm water and oily water and Firefighting System - Ground.5.1.1. After all equipment has arrived at the field site, according to the package list check the various parts fittings, auxiliary tools, and equipment document
13、 shall be complete. When checking the direct current equipment e.g. transformer-rectifier etc., the wire connection of inner section must be firm and reliable. 5.1.2. Before construction, the cathodic protection test posts shall be prepared according to the requirement of the design drawing; the out
14、side size and inner-structure shall be up to standard; the line connection shall be fixed. Before construction, the construction team shall get familiar with the types of test post for different areas based on the design drawing specification and install the post accurately section by section.5.1.3.
15、 The posts testing wire is connected with pipeline, using the copper thermal welding method,The color marking of the test conducting wire will be divided according to its function, and shall be uniformed through whole line.5.1.4. The bottom of the storage tanks is usually protected with impressed cu
16、rrent system where soil resistivity is high.5.2. Installation of cathodic protection sacrificial anodes.5.2.1. On receiving packaged anodes its integrity is verified, checking the envelopes are not broken and which are free of moisture, additionally checks the electrical continuity between the anode
17、 and the conductor cable without compromising the integrity of the package.5.2.2. The galvanic anodes type packaged native soil are filled with compacted at the bottom. 5.2.3. When the anodes and special filler are provided separately, the anodes are centered in the special filler, which filler is c
18、ompacted prior to native soil and lower inflation.5.2.4. When the sacrificial anodes are used to protect the internal surfaces of the tank bottom, the anodes may be bolted or welded to the bottom of the tanks. The connections are covered, but not the anode surfaces.5.2.5. When using tape type anode
19、at the bottom of the tanks, these are generally installed in clean, dry sand without special padding. The tape is carefully placed so that the anode is not in contact with the bottom of steel.5.2.6. During filling operations cares lead wires and connections are not broken or separated from the anode
20、 body for it is not allowed to be taken by the anode wires during transportation and installation.5.2.7. While supplies last cathodic protection facilities, the electrical supervisor in coordination with Quality inspector performs the inspection of the facility to verify their execution according to
21、 the designs and subsequently documented in the records.5.3. Installation of impressed current cathodic protection.5.3.1. Prior to installation of impressed current cathodic protection ensures that the structures present protect electrical continuity. For discontinuous structures with metal joints e
22、nsures when required.5.3.2. Impressed current anodes are inspected for defects, in accordance with the material specification, size and length of the leads, we review the anode cover is secure and that is not cracked, equal care is maintained while moving and installs the anodes. Cracked anodes are