低风压铝合金芯高导电率铝型线绞线的运用实践,电力论文.docx
《低风压铝合金芯高导电率铝型线绞线的运用实践,电力论文.docx》由会员分享,可在线阅读,更多相关《低风压铝合金芯高导电率铝型线绞线的运用实践,电力论文.docx(7页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、低风压铝合金芯高导电率铝型线绞线的运用实践,电力论文内容摘要:随着电网飞速发展,对导线的要求越来越高,以某220kV线路工程为例,通过年费用最小法对导线选型进行计算分析,推荐采用大截面节能导线。与常规钢芯铝绞线2 JL1/G1A-300/40相比,风荷载降低15%,电阻损耗分别减少12.7%,年费用低15.73万元/km低4.5%,经济效益显著。 本文关键词语:220kV输电线路; 低风压; 大截面导线; Abstract:With the rapid development of power grid, the demand for conductors is getting higher
2、and higher. Taking a 220 kV line project as an example, the conductor selection is calculated and analyzed by the method of minimum annual cost, and the large cross-section energy-saving conductor is recommended. Compared with the conventional steel core aluminum strand 2 JL1/G1 A-300/40, the wind l
3、oad is reduced by 15%, the resistance loss is reduced by 12.7%, and the annual cost is reduced by 157300 yuan/km(by 4.5%). 引言 高压输电线路导线选型研究是沟通输电线路的重要课题,对线路的输送容量、电能损耗、电磁环境有很大的影响。同时对整个工程的造价影响极大。因而,导线合理选型对沟通输电线路节约成本、降低工程造价及运行损耗有着特别深远的意义1。 本文以江西某工程为例,新建单回架空线路33.4公里,地形比例为丘陵50%、平地15%、泥沼35%。设计气象条件为基本风速27m/s
4、、设计覆冰10mm。输送容量416MW。 1 导线选型简介 根据系统远期输送的要求,对于常规钢芯铝绞线2 300mm2或1 720mm2及以上截面的才能知足要求。本论文仅对单分裂1 720mm2及以上截面导线进行研究。 1.1 钢芯铝绞线 该导线为常规截面导线,本次选取720mm2对应型号JL/G2A-720/50介入比选。 1.2 中强度铝合金绞线 该导线由中强度铝合金线绞合而成,为现前阶段广泛推广应用的三种节能导线之一。本次选取720mm2对应型号JLHA3-775介入比选。 1.3 钢芯铝合金绞线型线 在原有圆线同心绞架空导线上进行改良,以型线单线代替常规的圆线构造制成型线同心架空导线,
5、可提高导线的综合性能。本次选取 T 型型线JL3X/LHA1-660/240介入比选。 1.4 低风压导线 采用加强芯高导电率铝合金线LHA55.25,该铝合金产品导电率到达55.25%IACS,比国标要求的导电率还要高3%左右,抗拉强度为315MPa,与等构造的铝合金芯铝绞线比照,在保证导线的抗拉强度的同时,进一步降低了导线的电阻,提升了导线的节能效果。 同时采用低风压导线,该导线最外层采用型线构造和V形沟槽,使得导线外表构成一定的粗糙度,似高尔夫球状外外表。使导线外表构成一定的粗糙度,降低导线的阻力系数,进而降低了导线的风压。 本次选取1 JL3X/LHA1(DFY)-660/240低风压