1、 ABB-Page 1E x t e n d e d A u t o m a t i o n S y s t e m 8 0 0 x AFunctional safety Engineering-Layers of Protection ABB -Page 2FunctionalsafetyLayers of Protection AnalysisnFault Propagation ContextnEvent Tree MethodnLayers of Protection DefinitionnLOPA Event TreenInitiating Evnents and Failure R
2、atesnExample of Layers of Protection ABB -Page 3FunctionalsafetyFault Propagation modellingnAnalyze the Chain of events that leads to an accident Control SystemFailsOperator does not respond properlyMechanical relief failedOverpressure EventInitiating event ABB -Page 4FunctionalsafetyLayers of Prote
3、ction Analysis-LOPAnA variant of Event Tree AnalysisnMore structuresnLike event tree analysis,the initiating event start the chain of eventsnBranches are layers of protectionnConsider only two outcomenAccidentnNo Event ABB -Page 5FunctionalsafetyLOPA Version of Event TreePL2,failsPL1,failsPL3,failsA
4、ccidentQuantify using multiplications;all logical ANDs ABB -Page 6FunctionalsafetyEx,Column Rupture LOPAnDraw the LOPA diagram for following situationsnConsequence of the accident=fire due to distillation column rupture has a root cause of loss of cooling waternLayers of protectionnOperator respond
5、to alarms and stops the processnProcess generally designed to withstand loss of cooling waternThe column has a pressure relief valvenSource of ignition are controlled in the process area ABB -Page 7FunctionalsafetyEx:Column rupture LOPA ABB -Page 8FunctionalsafetyLOPA CalculationsnProceed as with ev
6、ent tree,but only need to calculate the frequency of accidentnResulting accident frequency is initiating event frequency multiplied by PFD of all protection layersnExamplenCooling water failure frequency is 0,5/yearnProtection layersnOperator response failure PFD=0,15nRelief valve failure PFD =0,07n
7、Process design inadequate PFD=0,01nIgnition source contacted PFD=0,3 ABB -Page 9FunctionalsafetyEx:Column Rupture,LOPAF=0,5/y*0,15*0,01*0,07*0,3=1,58E-5 per year ABB -Page 10FunctionalsafetyFailure Rate QuantificationnHistorical reliability data specific to your installation is best,but often diffic
8、ult to getnPlant maintenance and SIS function test data by equipment typenIndustry average data grouped by equipment typenSome expert judgment is still inevitable ABB -Page 11FunctionalsafetyUsing Maintenance and Function Test DatanCompanies usually keep maintenance logsnIEC 61511 requires function