1、上海浦东电线电缆集团有限公司0.6/1kV 聚氯乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002VV VLV VV22 VLV22 VV23 VLV23 VV32 VLV32 VV33VLV33 圆形线芯绝缘工序工艺卡片使用日期:共 16 页 第 1 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径导体直径标称厚度最薄厚度绝缘后标称直径模芯模套kV1*1.51/1.381.380.80.623.01.73.361*2.51/1.781.780.80.623.42.13.761*41/2.252.251.0
2、0.804.32.64.661*61/2.732.731.00.804.73.05.061*107/1.343.91.00.805.94.26.261*167/1.704.81.00.806.85.37.161*257/2.135.91.20.988.36.48.6101*357/2.566.91.20.989.37.49.6101*5010/2.568.11.41.1610.98.611.5101*7014/2.5610.01.41.1612.810.513.0101*9519/2.5611.51.61.3414.712.015.0151*12024/2.5612.71.61.3415.91
3、3.516.5151*15030/2.5614.51.81.5218.115.018.5151*18537/2.5616.02.01.7020.017.020.5151*24048/2.5618.22.21.8822.619.523.0201*30061/2.5620.22.42.0625.021.525.5201*40061/2.8523.52.62.2428.724.529.0251*50061/3.2626.72.82.4232.328.033.0251*63061/3.6629.82.82.4235.431.036.0251*80061/4.2034.02.82.4239.635.04
4、0.0251*100091/3.7538.03.02.644.039.044.525上海浦东电线电缆集团有限公司0.6/1kV 聚氯乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002VV VLV VV22 VLV22 VV23 VLV23 VV32 VLV32 VV33VLV33 绝缘工序工艺卡片使用日期:共 16 页 第 2 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV2*1.51/1.381.380.80.623.01.73.362*2.5
5、1/1.781.780.80.623.42.13.762*41/2.252.251.00.804.32.64.662*61/2.732.731.00.804.73.05.062*107/1.343.91.00.805.94.26.262*167/1.704.81.00.806.85.37.162*257/2.135.91.20.988.36.48.6102*357/2.566.91.20.989.37.49.6102*5010/2.565.11.41.167.913.520.5102*7014/2.566.21.41.169.016.523.5102*9519/2.567.31.61.3410
6、.519.027.0152*12024/2.568.31.61.3411.521.029.0152*15030/2.569.21.81.5212.823.032.0152*18537/2.5610.22.01.7014.226.036.0152*24048/2.5611.82.21.8816.229.540.5202*30061/2.5613.22.42.0618.032.044.0202*40061/2.8515.82.62.2421.035.048.025注:35mm2及以下为圆形结构,50mm2及以上为扇形结构。上海浦东电线电缆集团有限公司0.6/1kV 聚氯乙烯绝缘电力电缆文件编号:L
7、SL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002VV VLV VV22 VLV22 VV23 VLV23 VV32 VLV32 VV33VLV33 绝缘工序工艺卡片使用日期:共 16 页 第 3 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV3*1.51/1.381.380.80.623.01.73.363*2.51/1.781.780.80.623.42.13.763*41/2.252.251.00.804.32.64.663*61/2.732.731.00.804.7
8、3.05.063*107/1.343.91.00.805.94.26.263*167/1.704.81.00.806.85.37.163*257/2.135.91.20.988.36.48.6103*357/2.566.91.20.989.37.49.6103*5010/2.567.01.41.169.814.021.0103*7014/2.568.21.41.1611.016.023.0103*9519/2.569.41.61.3412.619.527.5153*12024/2.5611.11.61.3414.321.029.0153*15030/2.5612.21.81.5215.823.
9、032.0153*18537/2.5613.52.01.7017.525.535.5153*24048/2.5615.82.21.8820.229.040.0203*30061/2.5617.52.42.0622.333.045.0203*40061/2.8519.62.62.2424.836.049.025注:35mm2及以下为圆形结构,50mm2及以上为扇形结构。上海浦东电线电缆集团有限公司0.6/1kV 聚氯乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002VV VLV VV22 VLV22 VV23 VLV23 VV32 VLV3
10、2 VV33VLV33 绝缘工序工艺卡片使用日期:共 16 页 第 4 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV4*1.51/1.381.380.80.623.01.73.364*2.51/1.781.780.80.623.42.13.764*41/2.252.251.00.804.32.64.664*61/2.732.731.00.804.73.05.064*107/1.343.91.00.805.94.26.264*167/1.704.81.00.806.85.37.164*257/2.13
11、5.91.20.988.36.48.6104*357/2.566.91.20.989.37.49.6104*5010/2.568.21.41.1611.012.019.0104*7014/2.569.51.41.1612.314.021.0104*9519/2.5610.71.61.3413.917.525.5154*12024/2.5612.81.61.3416.019.027.0154*15030/2.5613.51.81.5217.121.030.0154*18537/2.5614.92.01.7018.923.033.0154*24048/2.5617.22.21.8821.626.0
12、37.0204*30061/2.5618.92.42.0623.729.041.0204*40061/2.8522.12.62.2427.333.046.025注:35mm2及以下为圆形结构,50mm2及以上为扇形结构。上海浦东电线电缆集团有限公司0.6/1kV 聚氯乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002VV VLV VV22 VLV22 VV23 VLV23 VV32 VLV32 VV33VLV33 绝缘工序工艺卡片使用日期:共 16 页 第 5 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直
13、径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV5*1.51/1.381.380.80.623.01.73.365*2.51/1.781.780.80.623.42.13.765*41/2.252.251.00.804.32.64.665*61/2.732.731.00.804.73.05.065*107/1.343.91.00.805.94.26.265*167/1.704.81.00.806.85.37.165*257/2.135.91.20.988.36.48.6105*357/2.566.91.20.989.37.49.6105*5010/2.568.11.41.1610
14、.98.611.5105*7014/2.5610.01.41.1612.810.513.0105*9519/2.5611.51.61.3414.712.015.0155*12024/2.5612.71.61.3415.913.516.5155*15030/2.5614.51.81.5218.115.018.5155*18537/2.5616.02.01.7020.017.020.5155*24048/2.5618.22.21.8822.619.523.0205*30061/2.5620.22.42.0625.021.525.5205*40061/2.8523.52.62.2428.724.52
15、9.025上海浦东电线电缆集团有限公司0.6/1kV 交联聚乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002YJV YJLV YJV22 YJLV22 YJV23 YJLV23 YJV32YJLV32 YJV33 YJLV33 绝缘工序工艺卡片使用日期:共 16 页 第 9 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径导体直径标称厚度最薄厚度绝缘后标称直径模芯模套kV1*1.51/1.381.380.70.532.81.73.361*2.51/1.781.780.70.533.22.13.761*41
16、/2.252.250.70.533.72.64.661*61/2.732.730.70.534.13.05.061*107/1.343.90.70.535.34.26.261*167/1.704.80.70.536.25.37.161*257/2.135.90.90.717.76.48.661*357/2.566.90.90.718.77.49.661*5010/2.568.11.00.8010.18.611.561*7014/2.5610.01.10.8912.210.513.0101*9519/2.5611.51.10.8913.712.015.0101*12024/2.5612.71.2
17、0.9815.113.516.5101*15030/2.5614.51.41.1617.315.018.5101*18537/2.5616.01.61.3419.217.020.5151*24048/2.5618.21.71.4321.619.523.0151*30061/2.5620.21.81.5223.821.525.5151*40061/2.8523.52.01.7027.524.529.0151*50061/3.2626.72.21.8831.128.033.0201*63061/3.6629.82.42.0634.631.036.0201*80061/4.2034.02.62.24
18、39.235.040.0251*100091/3.7538.02.82.4243.639.044.525上海浦东电线电缆集团有限公司0.6/1kV 交联聚乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002YJV YJLV YJV22 YJLV22 YJV23 YJLV23 YJV32YJLV32 YJV33 YJLV33 绝缘工序工艺卡片使用日期:共 16 页 第 10 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV2*1.51/1.381.38
19、0.70.532.81.73.362*2.51/1.781.780.70.533.22.13.762*41/2.252.250.70.533.72.64.662*61/2.732.730.70.534.13.05.062*107/1.343.90.70.535.34.26.262*167/1.704.80.70.536.25.37.162*257/2.135.90.90.717.76.48.662*357/2.566.90.90.718.77.49.662*5010/2.565.11.00.807.113.520.562*7014/2.566.21.10.898.416.523.5102*95
20、19/2.567.31.10.899.519.027.0102*12024/2.568.31.20.9810.721.029.0102*15030/2.569.21.41.1612.023.032.0102*18537/2.5610.21.61.3413.426.036.0152*24048/2.5611.81.71.4315.229.540.5152*30061/2.5613.21.81.5216.832.044.0152*40061/2.8515.82.01.7019.835.048.015注:35mm2及以下为圆形结构,50mm2及以上为扇形结构。上海浦东电线电缆集团有限公司0.6/1k
21、V 交联聚乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002YJV YJLV YJV22 YJLV22 YJV23 YJLV23 YJV32YJLV32 YJV33 YJLV33 绝缘工序工艺卡片使用日期:共 16 页 第 11 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV3*1.51/1.381.380.70.532.81.73.363*2.51/1.781.780.70.533.22.13.763*41/2.252.250.70.533.7
22、2.64.663*61/2.732.730.70.534.13.05.063*107/1.343.90.70.535.34.26.263*167/1.704.80.70.536.25.37.163*257/2.135.90.90.717.76.48.663*357/2.566.90.90.718.77.49.663*5010/2.567.01.00.809.014.021.063*7014/2.568.21.10.8910.416.023.0103*9519/2.569.41.10.8911.619.527.5103*12024/2.5611.11.20.9813.521.029.0103*1
23、5030/2.5612.21.41.1615.023.032.0103*18537/2.5613.51.61.3416.725.535.5153*24048/2.5615.81.71.4319.229.040.0153*30061/2.5617.51.81.5221.133.045.0153*40061/2.8519.62.01.7023.636.049.015注:35mm2及以下为圆形结构,50mm2及以上为扇形结构。上海浦东电线电缆集团有限公司0.6/1kV 交联聚乙烯绝缘电力电缆文件编号:LSL/JZ-GK-SL-JY-02编制依据:GB/T 12706.1-2002YJV YJLV Y
24、JV22 YJLV22 YJV23 YJLV23 YJV32YJLV32 YJV33 YJLV33 绝缘工序工艺卡片使用日期:共 16 页 第 12 页芯数*标称截面导体结构 mm绝 缘 mm模 具 mm火花试验电压mm2根/直径扇型高度或直径标称厚度最薄厚度绝缘后扇形高或直径模芯模套kV4*1.51/1.381.380.70.532.81.73.364*2.51/1.781.780.70.533.22.13.764*41/2.252.250.70.533.72.64.664*61/2.732.730.70.534.13.05.064*107/1.343.90.70.535.34.26.264
25、*167/1.704.80.70.536.25.37.164*257/2.135.90.90.717.76.48.664*357/2.566.90.90.718.77.49.664*5010/2.568.21.00.8010.212.019.064*7014/2.569.51.10.8911.714.021.0104*9519/2.5610.71.10.8912.917.525.5104*12024/2.5612.81.20.9815.219.027.0104*15030/2.5613.51.41.1616.321.030.0104*18537/2.5614.91.61.3418.123.03