电气专业毕业论文外文翻译.doc
《电气专业毕业论文外文翻译.doc》由会员分享,可在线阅读,更多相关《电气专业毕业论文外文翻译.doc(67页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、本科毕业设计外文文献及译文文献、资料题目:Designing Stable Control Loops文献、资料来源:期刊文献、资料发表(出版)日期:2010.3.25 院 (部): 信息与电气工程学院专 业: 电气工程与自动化班 级: 姓 名: 学 号: 指导教师: 翻译日期: 2011.3.10外文文献:Designing Stable Control LoopsThe objective of this topic is to provide the designer with a practical review of loop compensation techniques appl
2、ied to switching power supply feedback control. A top-down system approach is taken starting with basic feedback control concepts and leading to step-by-step design procedures, initially applied to a simple buck regulator and then expanded to other topologies and control algorithms. Sample designs a
3、re demonstrated with Math cad simulations to illustrate gain and phase margins and their impact on performance analysis. I. INTRODUCTIONInsuring stability of a proposed power supply solution is often one of the more challenging aspects of the design process. Nothing is more disconcerting than to hav
4、e your lovingly crafted breadboard break into wild oscillations just as its being demonstrated to the boss or customer, but insuring against this unfortunate event takes some analysis which many designers view as formidable. Paths taken by design engineers often emphasize either cut-and-try empirica
5、l testing in the laboratory or computer simulations looking for numerical solutions based on complex mathematical models. While both of these approach a basic understanding of feedback theory will usually allow the definition of an acceptable compensation network with a minimum of computational effo
6、rt.II. STABILITY DEFINEDFig. 1. Definition of stabilityFig. 1 gives a quick illustration of at least one definition of stability. In its simplest terms, a system is stable if, when subjected to a perturbation from some source, its response to that perturbation eventually dies out. Note that in any p
7、ractical system, instability cannot result in a completely unbounded response as the system will either reach a saturation level or fail. Oscillation in a switching regulator can, at most, vary the duty cycle between zero and 100% and while that may not prevent failure, it wills ultimate limit the r
8、esponse of an unstable system.Another way of visualizing stability is shown in Fig. 2. While this graphically illustrates the concept of system stability, it also points out that we must make a further distinction between large-signal and small-signal stability. While small-signal stability is an im
9、portant and necessary criterion, a system could satisfy thisrt quirement and yet still become unstable with a large-signal perturbation. It is important that designers remember that all the gain and phase calculations we might perform are only to insure small-signal stability. These calculations are
10、 based upon and only applicable to linear systems, and a switching regulator is by definition a non-linear system. We solve this conundrum by performing our analysis using small-signal perturbations around a large-signal operating point, a distinction which will be further clarified in our design pr
11、ocedure discussion。Fig. 2. Large-signal vs. small-signal stabilityIII. FEEDBACK CONTROL PRINCIPLESWhere an uncontrolled source of voltage (or current, or power) is applied to the input of our system with the expectation that the voltage (or current, or power) at the output will be very well controll
12、ed. The basis of our control is some form of reference, and any deviation between the output and the reference becomes an error. In a feedback-controlled system, negative feedback is used to reduce this error to an acceptable value as close to zero as we want to spend the effort to achieve. Typicall
13、y, however, we also want to reduce the error quickly, but inherent with feedback control is the tradeoff between system response and system stability. The more responsive the feedback network is, the greater becomes the risk of instability. At this point we should also mention that there is another
14、method of control feedforward.With feed forward control, a control signal is developed directly in response to an input variation or perturbation. Feed forward is less accurate than feedback since output sensing is not involved, however, there is no delay waiting for an output error signal to be dev
15、eloped, andfeedforward control cannot cause instability. It should be clear that feed forward control will typically not be adequate as the only control method for a voltage regulator, but it is often used together with feedback to improve a regulators response to dynamic input variations.The basis
16、for feedback control is illustrated with the flow diagram of Fig. 3 where the goal is for the output to follow the reference predictably and for the effects of external perturbations, such as input voltage variations, to be reduced to tolerable levels at the output Without feedback, the reference-to
17、-output transfer function y/u is equal to G, and we can express the output asy = GuWith the addition of feedback (actually the subtraction of the feedback signal)y = Gu - yHGand the reference-to-output transfer function becomesy/u=G/1+GHIf we assume that GH _ 1, then the overall transfer function si
18、mplifies toy/u=1/HFig. 3. Flow graph of feedback controlNot only is this result now independent of G,it is also independent of all the parameters of the system which might impact G (supply voltage, temperature, component tolerances, etc.) and is determined instead solely by the feedback network H (a
19、nd, of course, by the reference).Note that the accuracy of H (usually resistor tolerances) and in the summing circuit (error amplifier offset voltage) will still contribute to an output error. In practice, the feedback control system, as modeled in Fig. 4, is designed so thatG _ H and GH _ 1 over as
20、 wide a frequency range as possible without incurring instability. We can make a further refinement to our generalized power regulator with the block diagram shown in Fig. 5. Here we have separated the power system into two blocks the power section and the control circuitry. The power section handle
21、s the load current and is typically large, heavy, and subject to wide temperature fluctuations. Its switching functions are by definition, large-signal phenomenon, normally simulated in most stability analyses as just a two states witch with a duty cycle. The output filter is also considered as a pa
22、rt of the power section but can be considered as a linear block. Fig. 4. The general power regulatorIV. THE BUCK CONVERTER The simplest form of the above general power regulator is the buck or step down topology whose power stage is shown in Fig. 6. In this configuration, a DC input voltage is switc
23、hed at some repetitive rate as it is applied to an output filter. The filter averages the duty cycle modulation of the input voltage to establish an output DC voltage lower than the input value. The transfer function for this stage is defined bytON=switch on -timeT = repetitive period (1/fs)d = duty
24、 cycleFig. 5. The buck converter. Since we assume that the switch and the filter components are lossless, the ideal efficiency ofThis conversion process is 100%, and regulation of the output voltage level is achieved bycontrolling the duty cycle. The waveforms of Fig.6 assume a continuous conduction
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 电气专业 毕业论文 外文 翻译
限制150内