1、一般开关电源供应器的测试仪器及其特性(完整版)实用资料(可以直接使用,可编辑 完整版实用资料,欢迎下载)1.引言 /Introduction此文件描述一般开关电源供应器的测试仪器及其特性。This document describes general equipment used in switching power supply testing and their characteristics.- 示波器 /Oscilloscope.- 电压探头 /Voltage probe.- 交流电流探头 /AC current probe.- 数字式电压表 /DVM.- 有效值表 /RMS mete
2、r.- 功率表 /Power meter.- 温度测量表 /Temperature measurement.- 电子负载 /Electronic load.- 交流电源 /AC source.- 台式直流电源 /Bench top DC power supply.2.示波器 /Oscilloscope是用来显示一个或多个随时间快速变化的电量的设备。这个电量通常是指开关电源测试中的电压或电流。大多数示波器是用CRT(阴极射线管)显示的数字存储型示波器也有用液晶显示的。An instrument that produce a visible image of one or more rapidly
3、 varying electrical quantities with respect to time. The quantities are usually a voltage or current in switching power supply testing. The most usual type of oscilloscope use CRT (cathode ray tube) display, LCD display is also available for digital storage type. 2.1示波器类型 /Type of oscilloscopel 模拟示波
4、器不能存储。水平扫描是在示波器内部产生的 (除用XY模式)。射线束在垂直方向的位置随CH1或CH2的输入信号而变化。 Analog scope: No storage. The horizontal sweep is generated internally in the oscilloscope (except in XY mode). The vertical position of beam on the display will vary according the input signal to VERT (CH1 or CH2).l 数字存储示波器矢量显示(Tektronix 22
5、32)对于非存储模式类似仿真示波器。对于存储模式首先输入信号经模/数转换并存储在存储器中存储后的信号再经数/模转换然后调整光束的垂直位置。这种类型的示波器现在已经逐步被淘汰。 Digital storage scope, vector display, (Tektronix 2232):In non-store mode, this kind of scope is same as an analog scope. In storage mode, the input signal to VERT is first converted with A/D and stored in memory
6、, then the content of the memory will be converted back to analog signal with D/A and modulate the vertical position of the beam. This type of scope is phasing out now.l 数字存储示波器监控显示(Tektronix TDS3012)这种显示是监控显示(类似计算机显示)。首先输入信号必须由模/数转换并存储在存储器中。这类示波器没有类似仿真示波器的功能。Digital storage scope, monitor display (
7、Tektronix TDS3012): The display is a monitor display (similar to computer display). The input signal must be converted with A/D and stored in memory first. This kind of scope cannot function as an analog scope.2.2重要的控制 /Important control垂直 /Vertical.- 垂直增益(伏/格) /Vertical gain (V/div).- 垂直位置 /Vertica
8、l position- 直流耦合 /DC coupling- 交流耦合 /AC coupling水平 /Horizontal - 时间/格 /Time/div.- 水平位置 /Horizontal position.触发 /Trigger为了使波形的起点在每个屏幕的位置相同使用触发是必要的否则不能显示稳定的波形。Tigger is required so that the start point of the waveform on every screen is the same, otherwise no stable waveform can be seen on the display
9、.- 源CH1, CH2, Line 等。/Source: CH1, CH2, Line, Ext.- 电平 /Level.- 沿+-。/Slope : +-.- 偶合直流交流高频滤除TV。/Coupling : DC, AC, HF Rej, TV.- 触发延迟时间。/Trigger hold time.2.3使用注意事项 /Precaution in use.接地问题 /Earthing problem.l 通常示波器的地是与安全地相连而测试电路中的地对于对安全地来说是必需浮动的。In general, the scope ground is connected to safety ear
10、th, while the ground of circuit under test shall be floating with respect to safety earth.l 示波器的地不能接到任何高压变动的一端。Scope ground shall not be connected to any node with high voltage swing.l 测量两个变动端之间的电压波形(例如前置转换整流器)必须用相减的方法例如CH1-CH2。To measure the voltage waveform across 2 swinging node (e.g. forward con
11、verter rectifier), differential method shall be used, i.e. CH1-CH2.l 如果测试电路是浮动的示波器的地也可以接到除地以外的其它直流电平处。然而两个探头的地不可以接到两个非隔离的不同直流电平的地方。Scope ground may be connected to other DC level in the circuit other than ground provided the circuit under test is floating. However, 2 probe ground must not be connect
12、ed to 2 different non-isolated DC level.数字示波器问题/Digital scope probleml 数字示波器不是很适合测量纹波。模拟示波器的亮度调节可以让你区分100HZ的纹波开关纹波及尖峰。对于数字示波器如果尖峰很高在取样模式中尖峰会被显示成随机幅度的尖峰。在峰值检测模式中其它纹波成份会被掩盖。Digital oscilloscope is not very suitable for ripple measurement. The intensity modulation in analog scope let you distinguish 10
13、0Hz ripple, switching ripple, and spike. In digital scope, if the spike is high: In sample acquisition mode, it will be shown as random amplitude spikes. In peak-detect mode, it will mask all other ripple component.l TDS340每个屏幕取500个样。很多细节会在取样模式中丢失。对于有尖峰的波形尖峰的幅度是随机的并且在连波中会不同的。TDS340 captures 500 samp
14、les per screen. Many details may be lost in sample acquisition mode. For waveform with spkies, the magnitude of spike will be random and different on consecutive waveform.l TDS3012/3014每个屏幕取样10,000个。TDS340中对于有尖峰的波形尖峰的幅度会更加稳定。如果尖峰幅度依然变化尖峰的宽度必定很窄水平时间/格必须设定很快才能得到其稳定的尖峰幅度。TDS3012/3014 capture 10,000 sam
15、ples per screen. For waveform with spikes, the magnitude of spike will be much more consistent than with TDS340. If the spike amplitude is still varying between waveforms, then the spike width must be very narrow, the horizontal time/div shall be set faster to obtain consistent spike amplitude.3.电压探
16、头 /Voltage probe3.1电压探头的类型 /Type of voltage probel X1探头没有衰减输入阻抗跟示波器输入阻抗一样(通常是1兆欧)。由于对测试电路有很大的负载影响所以很少使用这种探头。X1 probe : no attenuation, input impedance follow that of scope input impedance (usually 1 Mohm). This type of probe is seldom used because of heavy loading effect on circuit under test.l X10探
17、头衰减10倍当使用的示波器的输入阻抗为1兆欧其输入阻抗为10兆欧输入电容大约为13pF。对直流和低频输入电压的峰值上限为600伏。X10 probe : attenuation of 10:1, input impedance 10 Mohm when used with a scope of 1 Mohm input impedance, input capacitance around 13pF. Input voltage peak limited to 600V for DC and low frequency.l X100探头例如Tektronix P6009衰减100倍当使用的示波
18、器的输入 阻抗为1兆欧其输入阻抗为10兆欧输入电容约为2.5pF。对直流和低频输入电压的峰值上限为1500伏。 X100 probe : e.g. Tektronix P6009, attenuation of 100:1, input impedance 10Mohm when used with a scope of 1 Mohm input impedance, input capacitacne 2.5 pF. Input voltage limited to 1500V for DC and low frequency.3.2使用注意事项 /Precaution in usel 无论
19、何时X10和X100的探头与示波器组合改变都需要用示波器上的方波校正探头的高频响应。Whenever a scope/probe combination for X10 and X100 probe changes. Recalibrate the high frequency response of the probe with the square wave on the scope.l 对于低频和逻辑测量如有任何从示波器的地到电路地的连接探头的地就可以不接。For low frequency and logic measurement, any ground connection fro
20、m scope ground to circuit ground is OK, the probe ground may be left open.l 对于高频或低幅值测量探头的地应接到测试电路中的适当位置。For high frequency, or low amplitude measurement, probe ground shall be connected to appropriate points in the circuit under test.l 探头的电容会对测试电路有影响例如当测量振荡器的时候电容会降低振荡频率。The probe capacitance may aff
21、ect the circuit being measured, e.g. the capacitance may lower the oscillating frequency when measuring an oscillator.l 探头不要接触热的部位例如TO-220金属板或正在焊锡中的零件脚。 Do not clip probe to hot parts, e.g TO-220 metal plate, or components lead that are being soldered.4.交流电流探头 /AC Current probe交流电流探头是利用电流变压器的原理来测试电流
22、的它的中心部分可以打开和卡紧在有电流流过的导线上。电压会按照某个比率产生在端口。只有高于某些频率的交流电流才能被准确的测到。AC current probe act as a current transformer which the core can be opened and clamped on a current carrying conductor. A voltage will be developed at the termination at certain ratio. Only AC current above certain frequency can be measur
23、ed accurately.4.1使用注意事项 /Precaution in usel 交流电流探头不能用来测量低频电流波形。(例如Tektronix P602110mA/mV文件3dB的截止频率点为120Hz2mA/mV档为450Hz)。AC current probe shall not be used to measure low freqeuncy current wavform. (e.g. Tektronix P6021, 3dB point is 120Hz at 10mA/mV, 450Hz at 2mA/mV).l 对于P6021电流波形峰值不能超过15Amp。Current
24、 waveform shall not exceed 15 Amp peak for P6021.5.数字式电压表 /DVM5.1直流电压测量 /DC voltage measurementl 基本功能是将直流电压转换成容易读出的数字显示。根据精密的需求分为三位半四位半五位半数字显示或更多位显示的。The basic function is to convert a DC voltage into a digital display which can be read easily. Depending on accuracy required, 3 1/2 digit, 4 1/2 digi