1、 4th International DAAAM Conference INDUSTRIAL ENGINEERING INNOVATION AS COMPETITIVE EDGE FOR SME 29 - 30th April 2004, Tallinn, Estonia PROGRAMMABLE LOGIC CONTROLLERS IN PROCESS AUTOMATION Ahti Mikkor, Lembit RoosimlderDepartment of Product Development, Institute of Machinery, Tallinn Technical Uni
2、versity, Ehitajate tee 5, 19086 Tallinn, Estonia ahti.mikkor Abstract: Nowadays, control problems are solved using operating components from a wide variety of technologies: electronics, hydraulics, pneumatics and mechanics. Functio-nality, reliability and price of the controlled system are deter-min
3、ed by the quality of the solution made. The paper concentrates on practical use of programmable logic controllers (PLC) that is based on the five years project development experience in this area. Successful solutions and problems are under focus. Specific hardware, controller programming problems,
4、data/signals exchange and human machine interfaces are considered. As a result the method for selecting programmable controllers according to specific needs is developed. Practical suggestions, possible hazards and warnings are proposed that could help to avoid mistakes. Key words: programmable cont
5、rollers, PLC, automation, automation systems, process automation. 1. INTRODUCTION Modern machinery consists of both mechanical and electronic parts. Overall functionality is determined by “balance” between these components. Initial planning and solution selection plays critical role in final result.
6、 In control methods the selection has to be made between relay-based circuits, special devices, programmable logic controllers (PLC) and new development electronics. This article is concentrated on PLC-s and experience that has collected over 5-year practical work with PLC-s. Strong and weak sides,
7、positive and negative practices are discussed. Suggestions weather to use programmable controllers or not have been formed to help decision making. The most important decision in planning PLC-based system is selecting processor type. Mistakes mean extra costs for modifications or even need for compl
8、etely new devices. The most common error is overestimating programming possibilities of small-sized processors. There are several methods for selecting PLC. Unfortunately most of them focus on electrical side of PLC-s and maximum count of signals allowed. They dont involve analysis to determine poss
9、ible special needs for user program or communications. Based on several existing methods, practical experience and future trends a new method for selecting PLC was developed. Ahti Mikkor has gained his experience by taking part in more than 15 big-scale automation projects. These projects include de
10、velopment of power consumption monitoring system in AS Kunda Nordic Cement factory, renewing testing rig for flowmeters, building Ahtme powerplant turbine safety systems, water treatment plants in towns Rakvere and Plva, waste water treatment plant in town Jgeva and development of monitoring system
11、for central heating network in Tartu.2. PROS AND CONS IN USING PROGRAMMABLE LOGIC CONTROLLERS 2.1 Positive arguments The main advantage that programmable controllers provide is flexibility (Jack, 2003). Behaviour of the system can be easily changed via program without any other alterations. Special
12、devices for example make any changes in control algorithm very hard to implement. Flexibility makes PLC-s well suitable for frequently changed applications, for example in robotics. In PLC-s the relations between inputs and outputs are determined by user program. By using advanced programming techno
13、logies it is much easier to implement complex control algorithms than in any hard-wired solutions. It makes PLC-s very competitive for complex tasks, for example in controlling chemical processes. Special modules allow vast amount of different signals to be connected to the PLC system. Use of PLC-s
14、should be considered in applications that require some “special” input or output signals. Typical example would be positioning using reference data from high-speed input. Typically PC visualization software packages are made for PLC-s. Some special devices have also PC software packages. Wide range
15、of communication options between PLC-s makes it possible to gather all information from field devices into one central control point. Communication lines between PLC-s allow using information collected from other parts of the system in local process control. Modern communication technologies enable
16、remote diagnostics and configuration (Jack, 2003). These two significantly reduce overall maintenance costs of the system. 2.2 Negative arguments Programmable controllers are not equipped with enough memory to store big amounts of data. Although future trends show growth in PLC memory sizes, special
17、 devices (recorders) are still better suited for standalone datalogging applications. For networked solutions there is possibility to use visualization software packages together with PLC-s to archive collected data in any database format necessary. If logged data amounts are small or there are also
18、 control functions included, its reasonable to still use PLC-s. About visualization software packages its good to know that in standard versions most of them do not support offline recording so that after communication breakdown it is not possible to acquire data backwards from PLC. Modern communica
19、tion options for PLC-s include standard protocols for example Ethernet. It is tempting to use existing office networks also as data carrier for automation system communications. Time has shown that it is better practice to keep these two separated if there is a need for constant online communication
20、. Hardly traceable temporal network overloads can cause problems also in automation system communications All PLC-s need be programmed. All programming works include risk for accidental errors in control algorithm. Special devices are well tested and generally free of this kind of problems. If avail
21、able, its economically thoughtful to use special devices. Safety applications that require highest degree of reliability should contain simplest devices and circuits possible. There is a rule that every new link in chain decreases overall reliability. In small applications its often cost saving to u
22、se relay-based circuits instead of PLC-s. 3. FUTURE TRENDS Progress in process automation systems is aiming at so called complete automation when all the human has to do is to enter the parameters of the product wanted and everything else is carried out by machines (Rosin, 2000). Although the destin
23、ation lies far ahead, trends indicate movement in that direction. Firstly, systems become more and more standardized. Big manufacturers organize their products into families. The aim is to reduce amount of knowledge needed for configuration and maintenance works of different devices from same compan
24、y. Its also important that this way built applications are easily expandable. Secondly, importance of communication is rising (Hughes, 2000). There are many reasons, some of more essentials are: Better collaboration of different parts of the system. Cutting costs on cabling. Less cabling results fal