1、BS EN15714-1:2009ICS 01.040.23;23.060.20NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBRITISH STANDARDIndustrial valves ActuatorsPart 1:Terminology and definitionsThis British Standardwas published underthe authority of theStandards Policy andStrategy Committee on 30November
2、2009 BSI 2009ISBN 978 0 580 54736 2Amendments/corrigenda issued since publicationDateCommentsBS EN 15714-1:2009National forewordThis British Standard is the UK implementation of EN 15714-1:2009.The UK participation in its preparation was entrusted to TechnicalCommittee PSE/18/5,Valve actuators.A lis
3、t of organizations represented on this committee can be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisionsof a contract.Users are responsible for its correct application.Compliance with a British Standard cannot confer immunityfrom legal obl
4、igations.标准分享网 w w w.b z f x w.c o m 免费下载w w w.b z f x w.c o mBS EN 15714-1:2009 EUROPEAN STANDARD NORME EUROPENNE EUROPISCHE NORM EN 15714-1 October 2009 ICS 01.040.23;23.060.20 English Version Industrial valves-Actuators-Part 1:Terminology and definitions Robinetterie industrielle-Actionneurs-Part
5、ie 1:Terminologie et dfinitions Industriearmaturen-Antriebe-Teil 1:Begriffe und Definitionen This European Standard was approved by CEN on 12 September 2009.CEN members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the
6、status of a national standard without any alteration.Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN Management Centre or to any CEN member.This European Standard exists in three official versions(English,French,German).A v
7、ersion in any other language made by translation under the respons bility of a CEN member into its own language and notified to the CEN Management Centre has the same status as the official versions.CEN members are the national standards bodies of Austria,Belgium,Bulgaria,Cyprus,Czech Republic,Denma
8、rk,Estonia,Finland,France,Germany,Greece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal,Romania,Slovakia,Slovenia,Spain,Sweden,Switzerland and United Kingdom.EUROPEAN COMMITTEE FOR STANDARDIZATION COMIT EUROPEN DE NORMALISATION EUROPISCHES KOMITEE
9、FR NORMUNG Management Centre:Avenue Marnix 17,B-1000 Brussels 2009 CEN All rights of exploitation in any form and by any means reserved worldwide for CEN national Members.Ref.No.EN 15714-1:2009:Ew w w.b z f x w.c o mBS EN 15714-1:2009EN 15714-1:2009(E)2 Contents Page Foreword.31Scope.42Normative ref
10、erences.43Common terms and definitions used for electric,pneumatic and hydraulic valve actuators.44Terms and definitions specific for pneumatic and/or hydraulic valve actuators.55Terms and definitions specific for electric valve actuators.7Bibliography.8 标准分享网 w w w.b z f x w.c o m 免费下载w w w.b z f x
11、 w.c o mBS EN 15714-1:2009EN 15714-1:2009(E)3 Foreword This document(EN 15714-1:2009)has been prepared by Technical Committee CEN/TC 69“Industrial valves”,the secretariat of which is held by AFNOR.This European Standard shall be given the status of a national standard,either by publication of an ide
12、ntical text or by endorsement,at the latest by April 2010,and conflicting national standards shall be withdrawn at the latest by April 2010.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights.CEN and/or CENELEC shall not be held respon
13、sible for identifying any or all such patent rights.According to the CEN/CENELEC Internal Regulations,the national standards organizations of the following countries are bound to implement this European Standard:Austria,Belgium,Bulgaria,Cyprus,Czech Republic,Denmark,Estonia,Finland,France,Germany,Gr
14、eece,Hungary,Iceland,Ireland,Italy,Latvia,Lithuania,Luxembourg,Malta,Netherlands,Norway,Poland,Portugal,Romania,Slovakia,Slovenia,Spain,Sweden,Switzerland and United Kingdom.w w w.b z f x w.c o mBS EN 15714-1:2009EN 15714-1:2009(E)4 1 Scope This document defines specific terms and definitions used f
15、or industrial valve actuators not included in EN 736-2 and EN 736-3.2 Normative references Not applicable.3 Common terms and definitions used for electric,pneumatic and hydraulic valve actuators Table 1 Common terms and definitions Term Definition ambient temperature environmental temperature of the
16、 location where the actuator is working blistering formation of bubbles or pimples on a coated surface,caused by the local loss of adhesion and lifting of the film from the underlying substrate(see EN ISO 4628-2)emergency closing/opening overriding operation allowing the actuator to be closed or ope
17、ned under emergency conditions emergency shut down ESD specific function of an actuator designed to perform a pre-determined operation(open/close/stayput)in an emergency situation end of travel predefined position related to a fully open or a fully closed condition end stop mechanical part,designed
18、to stop the actuator drive train at an end position end torque/thrust actuator maximum output torque/thrust available at the end of the stroke fail-safe actuator multi-turn,part-turn or linear actuator which is able to operate in a defined pre-determined way on loss of external power fail-safe posit
19、ion defined pre-determined position in which the actuator operates on loss of external power indicating arrangement device,externally visible,showing the position of the actuator/valve obturator limit switch contact that changes status when the stroking position of the actuator reaches a preset posi
20、tion linear actuator actuator which provides thrust for a defined linear stroke manual override device designed to operate manually the valve when required motive energy energy used to operate the actuator which can be electric,pneumatic or hydraulic operating cycle one complete opening and one comp
21、lete closing stroke of the valve,including the stopping phases operating/stroking/moving time duration of a complete stroke of the actuator NOTE For pneumatic and hydraulic actuators,the duration includes the pressurisation and/or de-pressurisation times and the movement of the actuator.标准分享网 w w w.
22、b z f x w.c o m 免费下载w w w.b z f x w.c o mBS EN 15714-1:2009EN 15714-1:2009(E)5 Table 1(continued)Term Definition output torque/thrust torque/thrust delivered by the actuator position transmitter device transmitting a signal proportional to the actuator position rated torque/thrust characterising fig
23、ure indicated by the actuator manufacturer used to define the maximum actuator operating torque/thrust capability NOTE Units:torque in Newton metres(Nm);thrust in Newton(N).test room temperature ambient air temperature where the actuator is tested run torque/thrust actuator output torque/thrust deve
24、loped between the seating/unseating positions seating/unseating torque actuator output torque required to seat/unseat the valve start torque/thrust actuator output torque/thrust at the beginning of the stroke,in the direction of the motive force defined stroke single and complete movement from one e
25、nd of travel to the other torque/thrust characteristics values which may vary through the actuator stroke travel limitation any device integrated in the actuator and designed to limit the travel/stroke travel value of actuator output turns,angular or linear movement between ends of travel 4 Terms an