阀门标准-ANSI FCI 70-2-2006 控制阀门座泄漏(天选打工人).pdf
![资源得分’ title=](/images/score_1.gif)
![资源得分’ title=](/images/score_1.gif)
![资源得分’ title=](/images/score_1.gif)
![资源得分’ title=](/images/score_1.gif)
![资源得分’ title=](/images/score_05.gif)
《阀门标准-ANSI FCI 70-2-2006 控制阀门座泄漏(天选打工人).pdf》由会员分享,可在线阅读,更多相关《阀门标准-ANSI FCI 70-2-2006 控制阀门座泄漏(天选打工人).pdf(9页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、 ANSI/FCI 70-2-2006 AMERICAN NATIONAL STANDARD CONTROL VALVE SEAT LEAKAGE Fluid Controls Institute,Inc.Sponsor:Fluid Controls Institute,Inc.1300 Sumner Ave Cleveland,Ohio 44115-2851 ii ANSI/FCI 70-2-2006 AMERICAN NATIONAL STANDARD Control Valve Seat Leakage Sponsor Fluid Controls Institute,Inc.标准分享网
2、 w w w.b z f x w.c o m 免费下载标准分享网 w w w.b z f x w.c o m 免费下载w w w.b z f x w.c o m iii American National Standard implies a consensus of those substantially concerned with its scope and provisions.An American National Standard is intended as a guide to aid the manufacturer,the consumer,and the general
3、 public.The existence of an American National Standard does not in any respect preclude anyone,whether he has approved the standard or not,from manufacturing,marketing,purchasing or using products,processes,or procedures not conforming to the standard.American National Standards are subject to perio
4、dic review and users are cautioned to obtain the latest editions.CAUTION NOTICE:This American National Standard may be revised or withdrawn at any time.The procedures of the American National Standards Institute require that action be taken to reaffirm,revise,or withdraw this standard no later than
5、five years from the date of publication.Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute.Sponsored and published by:FLUID CONTROLS INSTITUTE,INC.1300 Sumner Avenue Cleveland,OH 44115-2851 Phn:21
6、6/241-7333 Fax:216/241-0105 E-Mail:fcifluidcontrolsinstitute.org URL:www.fluidcontrolsinstitute.org Copyright 2006,1998,1968 by Fluid Controls Institute,Inc.All Rights Reserved No part of this publication may be reproduced in any form,in an electronic retrieval system or otherwise,without the prior
7、written permission of the publisher.Suggestions for improvement of this standard will be welcome.They should be sent to the Fluid Controls Institute,Inc.Printed in the United States of America American National Standard w w w.b z f x w.c o m iv CONTENTS PAGE Foreword.v 1.Purpose.1 2.Scope and Limita
8、tions.1 3.Definitions.1 4.Leakage Specifications and Classes.1-2 5.Test Procedures.2-4 6.References.4 Tables Table 1.2 Table 2.3 标准分享网 w w w.b z f x w.c o m 免费下载标准分享网 w w w.b z f x w.c o m 免费下载w w w.b z f x w.c o m v Foreword (This foreword is included for information only and is not part of ANSI/FC
9、I 70-2-2006,Control Valve Seat Leakage.)This voluntary standard has been compiled and issued in the public interest.It is intended to eliminate present misunderstandings and to assist and guide those people involved in the specification,use or manufacture of control valves.This standard,formerly kno
10、wn as ASME B16.104,was originally adopted on November 24,1970 as FCI 70-2.The standard has been revised several times through the years to stay current as the industry and its products have evolved and advanced.The standard was revised by the FCI Control Valve Section in 1998 in order to maintain co
11、nsistency with the appropriate IEC Standards(IEC 534-4).The standard was revised in 2003 to add the option to permit low pressure gas testing to determine Class V leakage.During the canvass of the 2003 version,one respondent asked for the standard to be modified to specifically exclude on/off valves
12、 used for tight shut-off.The FCI Control Valve and Regulator Section notes that FCI 70-2 has been intended to apply to control valve seat leakage.If line isolation and/or absolute tight shut-off is a normal expectation of the valve application,the FCI Control Valve and Regulator Sections recommend s
13、pecifying another standard,such as API 598,“Valve Test and Inspection.”The existence of a Fluid Controls Institute(FCI)standard does not in any respect preclude any member or non-member from manufacturing or selling products not conforming to this standard nor is the FCI responsible for its use.FCI
14、recognizes the need to periodically review and update this standard.Suggestions for improvement should be forwarded to the Fluid Controls Institute,Inc.,1300 Sumner Avenue,Cleveland,Ohio,44115-2851.All constructive suggestions for expansion and revision of this standard are welcome.w w w.b z f x w.c
15、 o m 1 ANSI/FCI 70-2-2006 AMERICAN NATIONAL STANDARD Control Valve Seat Leakage 1.PURPOSE 1.1 This standard establishes a series of seat leakage classes for control valves and defines the test procedures.2.SCOPE&LIMITATIONS 2.1 Selection of a leakage class is not restricted as to valve design,but ac
16、ceptable values for various commercially available designs are suggested for each class under Section 4.2.2 The standard cannot be used as a basis for predicting leakage at conditions other than those specified.2.3 This standard is similar to IEC 60534-4,except that no provision is made for Class IV
17、-S1 and the standard is applicable for valves with a Cv value less than 0.1.The air leakage test and allowable leak rates for Class V are equivalent to the water test and allowable water leakage rates for a water test performed at a nominal temperature of 60F.3.DEFINITIONS 3.1 Control Valve 3.1.1 A
18、valve with a power positioning actuator for moving a closure member to any position relative to a valve seat or seats in response to and in proportion to an external signal.The energy for a control valve actuator is derived from an independent source.3.1.2 Control valve body subassemblies on which a
19、n actuator is to be mounted at some later date are within the intent of this definition.3.2 Cv-An experimentally determined valve sizing coefficient.(Ref.ISA S75.01,ISA S75.02 and FCI Standard 84-1).3.3 Rated Valve Capacity.The quantity of test fluid(air or water)that would pass through the valve at
20、 rated travel under the stated pressure conditions as determined by the appropriate equations and manufacturers ratings.3.4 Rated Travel.The valve travel at which the manufacturers rating is established.3.5 Seat Leakage.The quantity of test fluid passing through an assembled valve in the closed posi
21、tion under the test conditions as defined.4.LEAKAGE SPECIFICATIONS&CLASSES 4.1 The maximum allowable seat leakage as specified for each class shall not exceed the seat leakage in Table 1 using the test procedure as defined in Section 5.For Classes II through VI each and every valve shall be tested.4
22、.2 Leakage Classes 4.2.1 CLASS I.A modification of any Class II,III or IV valve where design intent is the same as the basic class,but by agreement between user and supplier,no test is required.4.2.2 CLASS II.This class establishes the maximum permissible leakage generally associated with commercial
23、 double-seat control valves or balanced single-seat control valves with a piston ring seal and metal-to-metal seats.Use test procedure Type A.4.2.3 CLASS III.This class establishes the maximum permissible leakage generally associated with Class II(4.2.2),but with a higher degree of seat and seal tig
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 阀门标准-ANSI FCI 70-2-2006 控制阀门座泄漏天选打工人 阀门 标准 ANSI 70 2006 控制 泄漏 天选打 工人
![提示](https://www.taowenge.com/images/bang_tan.gif)
限制150内