(6.2.10)--高度传感器HF-500C汽车运用工程.pdf
《(6.2.10)--高度传感器HF-500C汽车运用工程.pdf》由会员分享,可在线阅读,更多相关《(6.2.10)--高度传感器HF-500C汽车运用工程.pdf(22页珍藏版)》请在淘文阁 - 分享文档赚钱的网站上搜索。
1、HF SensorsHF-250C/HF-500C/HF-750COptical Laser Height Sensor with CORREVITSF Housing ProfileforNon-contact distance measurementUSER MANUALVOLUME ISensor HardwareUser ManualHF-250C/HF-500C/HF-750C Sensor 2009 CORRSYS-DATRON Sensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/092Note:For a general de
2、scription of the CeCalWin Pro Software refer to the separate user manual Volume II.For the specific software description for the HF-250C/HF-500C/HF-750C Sensor refer to the separate user manual Volume III.User ManualHF-250C/HF-500C/HF-750C Sensor 2009 CORRSYS-DATRON Sensorsysteme GmbH HFxC_m-072-073
3、-078-p1-e-rev002 02/093VOLUME I-Sensor HardwareTable of ContentsGeneral Information .4Safety Instructions .51.Overview .62.Extent of Delivery.83.Technical Data.93.1Specifications.93.2Pin Assignments .103.3Sensor Settings .113.3.1Number of Averaged Values .113.3.2 Buffer Time .114.Set-up and Connecti
4、on .124.1Mounting Options.124.2Sensor Mounting Jig .134.3Mounting Instructions .144.3.1Installation with Magnetic Plate Holder .144.3.2Installation with Suction Holder.174.4Connecting the Sensor.214.3Sensor Configuration .215.Trouble Shooting.22User ManualHF-250C/HF-500C/HF-750C Sensor 2009 CORRSYS-
5、DATRON Sensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/094General InformationLegal NoticeInformation furnished is believed to be accurate and reliable.However,CORRSYS-DATRON assumesno responsibility for the consequences of use of such information nor for any infringement of patentsor other righ
6、ts of third parties which may result from its use.No license is granted by implication or oth-erwise under any patent or patent rights of CORRSYS-DATRON.Specifications mentioned in this pub-lication are subject to change without notice and do not represent a commitment on the part ofCORRSYS-DATRON.T
7、his publication supersedes and replaces all information previously supplied.All brand names are trademarks of their respective holders.Copyright NoticeCopyright 2009,CORRSYS-DATRONRevisionHFxC_m-072-073-078-p1-e-rev002 02/09ContactInternational Headquarters:CORRSYS-DATRON Sensorsysteme GmbHCharlotte
8、-Bamberg-Str.1235578 Wetzlar/GermanyPhone+49(6441)9282-0Hotline+49(6441)9282-82Fax+49(6441)9282-17E-mail salescorrsys-URLwww.corrsys-North American Headquarters:CORRSYS-DATRON Sensorsystems,Inc.40000 Grand River,Suite 503Novi,MI 48375/USAPhone+1(248)615-2035Toll-free+1(800)832-0732Fax+1(248)615-2184
9、E-mail USA-salescorrsys-URLwww.corrsys-China Headquarters:CORRSYS-DATRON Sensorsysteme GmbH,China OfficeRoom 610,JinTianDi International Mansion,No.998 RenMin Road,Shanghai(200021),P.R.ChinaTel.:+86-21-63114144Fax:+86-21-63114154E-mail:Xiaoying.Licorrsys-URL:www.corrsys-User ManualHF-250C/HF-500C/HF
10、-750C Sensor 2009 CORRSYS-DATRON Sensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/095Safety InstructionsPlease read carefully before operating the equipment.CORRSYS-DATRON is not responsible for damage that may occur when this system is used inany way other than that for which it is intended.To
11、assure safe and proper operation,all supplied equipment,components and/or accessories must becarefully transported and stored,as well as professionally installed and operated.Careful maintenanceand usage in full accordance with operating instructions is imperative.CORRSYS-DATRON equipment should be
12、installed and operated only by qualified persons who arefamiliar with devices of this type.Local regulations may not permit the operation of motor vehicles on public highways while theequipment is mounted on the exterior of the vehicle.Use the equipment only for intended applications.Improper applic
13、ation is not advised.Do not modify or change the equipment or its accessories in any way.Improper use or mounting of the equipment may affect the safety of the vehicle and/or occupants.The equipment must not be mounted and/or operated in any way that may compromise vehicle or and/or occupant safety.
14、Equipment must be mounted firmly and securely.Use only original equipment,components and/or accessories included in the scope of delivery.Do not mount equipment,components and/or accessories near heat sources(e.g.exhaust).Do not use defective or damaged equipment,components and/or accessories.Always
15、 note correct pin assignments and operating voltages when connecting equipment topower supplies,data acquisition/evaluation systems,and/or any other applicable system orcomponent.Equipment may be damaged if not properly connected and/or operated.For additional information,please call the CORRSYS-DAT
16、RON Hotline:+49(6441)9282-82or email:hotlinecorrsys-.Caution:Laser radiation is emitted from this aperture!Do not stare into beam!Laser class 3R according to DIN EN 60825-1:2001-11Laser Power:1x6-pin Lemo,#K070-182-20-17.(1)14992Signal cable,1m 8-pin.Binder with cable-1xBNC 2x Banana,#K070-381-10-18
17、.(1)14991RS-232 Output cable,1m 8-pin Binder with cable-1xSub-D 2x Banana,#K070-382-10-19.(1)15622CAN Output cable,1m 8-pin Binder with cable-1xSub-D 2x Banana,#K072-382-10-110.(1)11343Software CeCalWin Pro11.(1)13539TurboLab Dynamics Pro 12.(2)14516Screw DIN912 M5x30 A213.(2)15576Disc DIN125 di=5,3
18、mm Polyamid 14.(1)15887Screw Driver Torx 15.(1)14283Allen wrench 4mm16.(1)14643Mini folding rule Corrsys Datron17.(1)13971USB-Adapter(without picture)Standard delivery HF-500C Sensor,Art.no.153801.(1)15564Sensor head HF-500C/2.-17.as described above for the HF-250C SensorStandard delivery HF-750C Se
19、nsor,Art.no.159141.(1)15913Sensor head HF-750C/2.-17.as described above for the HF-250C Sensor1243567891011+1213+141615User ManualHF-250C/HF-500C/HF-750C Sensor 2009 CORRSYS-DATRON Sensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/0993.Technical Data3.1SpecificationsTechnical SpecificationsHF-250
20、CHF-500CHF-750CMeasuring range:100.350 mm125.625 mm150.900 mmResolution:0.1 mm0.2 mm0.3 mmLinearity:0.2%0.2%0.3%For all HF Senors:Sampling rate*:1.8 kHzLight source:LaserLaser Power:5 mWLaser Class:3R(IEC 60825-1)Wave length:660 nm(red)Approx.spot size:1 mm x 2 mmOutputsAnalog,RS232,CAN busSystem Sp
21、ecificationsOutput voltage0.10 VPower supply:9 18 V;(125 mA 12 V DC)Temperature range:Operating:-5 60CStorage:-10 70CSystem protection of the sensor:IP 67Weight:155 g(without cable)Dimensions of the sensor(l x w x h):100 mm x 20 mm x 40 mm(without spray guard)Case:aluminum,anodized*Sampling rates up
22、 to 8kHz are possible on surfaces with high reflectionThe HF-xxxC Sensors are compatible with the standard CORRSYS-DATRON mounting system.CAUTION-LASER RADIATIONDo not stare into beam!Laser Class 3R according to DIN EN 60825-1:2001-11Laser Power 5 mWWave Length660 nmUser ManualHF-250C/HF-500C/HF-750
23、C Sensor 2009 CORRSYS-DATRON Sensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/09103.2Pin AssignmentsSensor Connector,9 pin MIL ConnectorSignal Cable,1m 8 pin Binder with cable?1 x 6 pin LemoSignal Cable,1m 8 pin Binder with cable?1 x BNC&2 x 4 mm bunch pin plugAnalog/Digital-#K070-182-10-5Pin 1:
24、TXTPin 2:RXDPin 3:CAN+Pin 4:CAN-Pin 5:ShieldPin 6:GNDPin 7:SignalPin 8:9.18 VPin 9:0 V#K070-182-20-1Pin 1:n.c.Pin 2:12 VPin 3:GNDPin 4:n.c.Pin 5:SignalPin 6:0 V#K070-381-10-1BNC Sig:SignalBNC Shield:GNDbunch plug black0Vbunch plug red12VUser ManualHF-250C/HF-500C/HF-750C Sensor 2009 CORRSYS-DATRON S
25、ensorsysteme GmbH HFxC_m-072-073-078-p1-e-rev002 02/09113.3 Sensor SettingsThe following parameters can be set with the help of CeCalWin Pro.3.3.1 Average TimeDue to the high sampling rate and the small measuring spot,the sensor signal may be quite rough onuneven surfaces but it is possible to smoot
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- 6.2 10 高度 传感器 HF 500 汽车 运用 工程
限制150内